Literature DB >> 24198866

Anomaly Detection and Artifact Recovery in PET Attenuation-Correction Images Using the Likelihood Function.

Charles M Laymon1, James E Bowsher.   

Abstract

In dual modality PET/CT, CT data are used to generate the attenuation correction applied in the reconstruction of the PET emission image. This requires converting the CT image into a 511-keV attenuation map. Algorithms for making this transformation require assumptions about the makeup of material within the patient. Anomalous material such as contrast agent administered to enhance the CT scan confounds conversion algorithms and has been observed to result in inaccuracies, i.e., inconsistencies with the true 511-keV attenuation present at the time of the PET emission scan. These attenuation artifacts carry through to the final attenuation-corrected PET emission image and can resemble diseased tissue. We propose an approach to correcting this problem that employs the attenuation information carried by the PET emission data. A likelihood-based algorithm for identifying and correcting of contrast is presented and tested. The algorithm exploits the fact that contrast artifacts manifest as too-high attenuation values in an otherwise high quality attenuation image. In a separate study, the performance of the loglikelihood as an objective-function component of a detection/correction algorithm, independent of any particular algorithm was mapped out for several imaging scenarios as a function of statistical noise. Both the full algorithm and the loglikelihood performed well in studies with simulated data. Additional studies including those with patient data are required to fully understand their capabilities.

Entities:  

Year:  2013        PMID: 24198866      PMCID: PMC3815546          DOI: 10.1109/JSTSP.2012.2237380

Source DB:  PubMed          Journal:  IEEE J Sel Top Signal Process        ISSN: 1932-4553            Impact factor:   6.856


  23 in total

1.  Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.

Authors:  Gerald Antoch; Lutz S Freudenberg; Thomas Egelhof; Jörg Stattaus; Walter Jentzen; Jörg F Debatin; Andreas Bockisch
Journal:  J Nucl Med       Date:  2002-10       Impact factor: 10.057

2.  A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution.

Authors:  Johan Nuyts; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2003-09       Impact factor: 10.048

Review 3.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

4.  An accelerated convergent ordered subsets algorithm for emission tomography.

Authors:  Ing-Tsung Hsiao; Anand Rangarajan; Parmeshwar Khurd; Gene Gindi
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

5.  A generalized Gaussian image model for edge-preserving MAP estimation.

Authors:  C Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1993       Impact factor: 10.856

6.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

7.  Ordered subsets algorithms for transmission tomography.

Authors:  H Erdogan; J A Fessler
Journal:  Phys Med Biol       Date:  1999-11       Impact factor: 3.609

8.  Computerized three-dimensional segmented human anatomy.

Authors:  I G Zubal; C R Harrell; E O Smith; Z Rattner; G Gindi; P B Hoffer
Journal:  Med Phys       Date:  1994-02       Impact factor: 4.071

9.  An EM algorithm for estimating SPECT emission and transmission parameters from emissions data only.

Authors:  A Krol; J E Bowsher; S H Manglos; D H Feiglin; M P Tornai; F D Thomas
Journal:  IEEE Trans Med Imaging       Date:  2001-03       Impact factor: 10.048

10.  PET attenuation coefficients from CT images: experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients.

Authors:  C Burger; G Goerres; S Schoenes; A Buck; A H R Lonn; G K Von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-04-19       Impact factor: 9.236

View more
  1 in total

Review 1.  Improved Detection of Small Pulmonary Nodules Through Simultaneous MR/PET Imaging.

Authors:  Fernando E Boada; Thomas Koesters; Kai Tobias Block; Hersh Chandarana
Journal:  Magn Reson Imaging Clin N Am       Date:  2017-02-22       Impact factor: 2.266