Literature DB >> 24193351

Electroretinographic assessment of retinal function during acute exposure to normobaric hypoxia.

Andreas Schatz1, Maurice Breithaupt, Jens Hudemann, Andreas Niess, André Messias, Eberhart Zrenner, Karl Ulrich Bartz-Schmidt, Florian Gekeler, Gabriel Willmann.   

Abstract

BACKGROUND: The current study aimed to investigate retinal function during exposure to normobaric hypoxia.
METHODS: Standard Ganzfeld ERG equipment (Diagnosys LLC, Cambridge, UK) using an extended ISCEV protocol was applied to explore intensity-response relationship in dark- and light- adapted conditions in 13 healthy volunteers (mean age 25 ± 3 years). Baseline examinations were performed under atmospheric air conditions at 341 meters above sea level (FIO2 of 21 %), and were compared to hypoxia (FIO2 of 13.2 %) by breathing a nitrogen-enriched gas mixture for 45 min. All subjects were monitored using infrared oximetry and blood gas analysis.
RESULTS: The levels of PaCO2 changed from 38.4 ± 2.7 mmHg to 36.4 ± 3.0 mmHg, PaO2 from 95.5 ± 1.9 mmHg to 83.7 ± 4.6 mmHg, and SpO2 from 100 ± 0 % to 87 ± 4 %, from baseline to hypoxia respectively. A significant decrease (p < 0.05) was found for saturation amplitude of the dark-adapted b-wave intensity-response function (Vmax), dark-adapted a- and b-wave amplitudes of combined rod and cone responses (3 and 10 cd.s/m(2)), light-adapted b-wave amplitudes of single flash (3 and 10 cd.s/m(2)), and flicker responses (5-45 Hz) during hypoxia compared to baseline, without changes in implicit times. The a-wave slope of combined rod and cone responses (3 and 10 cd.s/m(2)) and the oscillatory potentials were significantly lower during hypoxia (p < 0.05). A isolated light-adapted ON response (250 ms flash) showed a reduction of amplitudes at hypoxia (p < 0.05), but no changes were observed for the OFF response.
CONCLUSIONS: The results show significant impairment of retinal function during simulated normobaric short-term hypoxia affecting specific retinal cells of rod and cone pathways.

Entities:  

Mesh:

Year:  2013        PMID: 24193351     DOI: 10.1007/s00417-013-2504-3

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  36 in total

1.  The photopic negative response of the flash electroretinogram in retinal vein occlusion.

Authors:  Hongling Chen; Dezheng Wu; Shizhou Huang; Hong Yan
Journal:  Doc Ophthalmol       Date:  2006-08-30       Impact factor: 2.379

Review 2.  Functional loss in early age-related maculopathy: the ischaemia postreceptoral hypothesis.

Authors:  B Feigl; B Brown; J Lovie-Kitchin; P Swann
Journal:  Eye (Lond)       Date:  2006-05-05       Impact factor: 3.775

3.  Photopic 30 Hz flicker ERG as a predictor for rubeosis in central retinal vein occlusion.

Authors:  J Larsson; S Andréasson
Journal:  Br J Ophthalmol       Date:  2001-06       Impact factor: 4.638

4.  RGC sensitivity to mild systemic hypoxia.

Authors:  Hélène Kergoat; Marie-Eve Hérard; Marianne Lemay
Journal:  Invest Ophthalmol Vis Sci       Date:  2006-12       Impact factor: 4.799

5.  Assessment of "non-recordable" electroretinograms by 9 Hz flicker stimulation under scotopic conditions.

Authors:  Andreas Schatz; Robert Wilke; Torsten Strasser; Florian Gekeler; Andre Messias; Eberhart Zrenner
Journal:  Doc Ophthalmol       Date:  2011-12-18       Impact factor: 2.379

6.  Electrophysiological consequences of retinal hypoxia.

Authors:  R A Linsenmeier
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1990       Impact factor: 3.117

7.  Local neuroretinal function during acute hypoxia in healthy older people.

Authors:  Beatrix Feigl; Ian B Stewart; Brian Brown; Andrew J Zele
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-02       Impact factor: 4.799

8.  Neuroretinal function during mild systemic hypoxia.

Authors:  David Tinjust; Hélène Kergoat; John V Lovasik
Journal:  Aviat Space Environ Med       Date:  2002-12

9.  Improved electrode for electroretinography.

Authors:  W W Dawson; G L Trick; C A Litzkow
Journal:  Invest Ophthalmol Vis Sci       Date:  1979-09       Impact factor: 4.799

10.  Oxygen distribution and consumption in the cat retina during normoxia and hypoxemia.

Authors:  R A Linsenmeier; R D Braun
Journal:  J Gen Physiol       Date:  1992-02       Impact factor: 4.086

View more
  4 in total

1.  Cone implicit time as a predictor of visual outcome in macular hole surgery.

Authors:  Sten Andréasson; Fredrik Ghosh
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2014-05-02       Impact factor: 3.117

2.  ISCEV extended protocol for the stimulus-response series for the dark-adapted full-field ERG b-wave.

Authors:  Mary A Johnson; Brett G Jeffrey; André M V Messias; Anthony G Robson
Journal:  Doc Ophthalmol       Date:  2019-03-30       Impact factor: 2.379

3.  cGMP-Phosphodiesterase Inhibition Prevents Hypoxia-Induced Cell Death Activation in Porcine Retinal Explants.

Authors:  Lorena Olivares-González; Cristina Martínez-Fernández de la Cámara; David Hervás; María Pilar Marín; Agustin Lahoz; José María Millán; Regina Rodrigo
Journal:  PLoS One       Date:  2016-11-18       Impact factor: 3.240

4.  ISCEV extended protocol for the photopic On-Off ERG.

Authors:  Maja Sustar; Graham E Holder; Jan Kremers; Claire S Barnes; Bo Lei; Naheed W Khan; Anthony G Robson
Journal:  Doc Ophthalmol       Date:  2018-06-22       Impact factor: 2.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.