Literature DB >> 24188809

Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner.

Jiang Du1, Guolin Ma2, Shihong Li3, Michael Carl4, Nikolaus M Szeverenyi5, Scott VandenBerg6, Jody Corey-Bloom7, Graeme M Bydder5.   

Abstract

White matter of the brain contains a majority of long T2 components as well as a minority of short T2 components. These are not detectable using clinical magnetic resonance imaging (MRI) sequences with conventional echo times (TEs). In this study we used ultrashort echo time (UTE) sequences to investigate the ultrashort T2 components in white matter of the brain and quantify their T2*s and relative proton densities (RPDs) (relative to water with a proton density of 100%) using a clinical whole body 3T scanner. An adiabatic inversion recovery prepared dual echo UTE (IR-dUTE) sequence was used for morphological imaging of the ultrashort T2 components in white matter. IR-dUTE acquisitions at a constant TR of 1000 ms and a series of TIs were performed to determine the optimal TI which corresponded to the minimum signal to noise ratio (SNR) in white matter of the brain on the second echo image. T2*s of the ultrashort T2 components were quantified using mono-exponential decay fitting of the IR-dUTE signal at a series of TEs. RPD was quantified by comparing IR-dUTE signal of the ultrashort T2 components with that of a rubber phantom. Nine healthy volunteers were studied. The IR-dUTE sequence provided excellent image contrast for the ultrashort T2 components in white matter of the brain with a mean signal to noise ratio of 18.7 ± 3.7 and a contrast to noise ratio of 14.6 ± 2.4 between the ultrashort T2 white matter and gray matter in a 4.4 min scan time with a nominal voxel size of 1.25 × 1.25 × 5.0mm(3). On average a T2* value of 0.42 ± 0.08 ms and a RPD of 4.05 ± 0.88% were demonstrated for the ultrashort T2 components in white matter of the brain of healthy volunteers at 3T.
© 2013.

Entities:  

Keywords:  Adiabatic IR; Proton density; T2*; Ultrashort T2; Ultrashort echo time; White matter

Mesh:

Year:  2013        PMID: 24188809      PMCID: PMC4091919          DOI: 10.1016/j.neuroimage.2013.10.053

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  32 in total

1.  Characterizing white matter with magnetization transfer and T(2).

Authors:  G J Stanisz; A Kecojevic; M J Bronskill; R M Henkelman
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  Magnetization transfer in MRI: a review.

Authors:  R M Henkelman; G J Stanisz; S J Graham
Journal:  NMR Biomed       Date:  2001-04       Impact factor: 4.044

3.  Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

Authors:  Mark D Does; John C Gore
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

4.  A pathology-MRI study of the short-T2 component in formalin-fixed multiple sclerosis brain.

Authors:  G R Moore; E Leung; A L MacKay; I M Vavasour; K P Whittall; K S Cover; D K Li; S A Hashimoto; J Oger; T J Sprinkle; D W Paty
Journal:  Neurology       Date:  2000-11-28       Impact factor: 9.910

5.  MRI of the brain with ultra-short echo-time pulse sequences.

Authors:  A Waldman; J H Rees; C S Brock; M D Robson; P D Gatehouse; G M Bydder
Journal:  Neuroradiology       Date:  2003-09-24       Impact factor: 2.804

6.  Methodology for the measurement and analysis of relaxation times in proton imaging.

Authors:  J R MacFall; F W Wehrli; R K Breger; G A Johnson
Journal:  Magn Reson Imaging       Date:  1987       Impact factor: 2.546

7.  Detection of molecular motion in lyophilized myelin by nuclear magnetic resonance.

Authors:  H Lecar; G Ehrenstein; I Stillman
Journal:  Biophys J       Date:  1971-02       Impact factor: 4.033

8.  Three-pool model of white matter.

Authors:  Jack L Lancaster; Trevor Andrews; L Jean Hardies; Stephen Dodd; Peter T Fox
Journal:  J Magn Reson Imaging       Date:  2003-01       Impact factor: 4.813

9.  Another approach to protons with constricted mobility in white matter: pilot studies using wideline and high-resolution NMR spectroscopy.

Authors:  A Ramani; A E Aliev; G J Barker; P S Tofts
Journal:  Magn Reson Imaging       Date:  2003-11       Impact factor: 2.546

10.  Precise estimate of fundamental in-vivo MT parameters in human brain in clinically feasible times.

Authors:  A Ramani; C Dalton; D H Miller; P S Tofts; G J Barker
Journal:  Magn Reson Imaging       Date:  2002-12       Impact factor: 2.546

View more
  37 in total

1.  Inversion recovery ultrashort echo time imaging of ultrashort T2 tissue components in ovine brain at 3 T: a sequential D2 O exchange study.

Authors:  Shu-Juan Fan; Yajun Ma; Eric Y Chang; Graeme M Bydder; Jiang Du
Journal:  NMR Biomed       Date:  2017-07-21       Impact factor: 4.044

2.  Inversion recovery UTE based volumetric myelin imaging in human brain using interleaved hybrid encoding.

Authors:  Hyungseok Jang; Yajun Ma; Adam C Searleman; Michael Carl; Jody Corey-Bloom; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2019-09-18       Impact factor: 4.668

3.  Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: Bicomponent T2* analysis of native and deuterated ovine brain specimens.

Authors:  Shu-Juan Fan; Yajun Ma; Yanchun Zhu; Adam Searleman; Nikolaus M Szeverenyi; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

4.  Assessment of the myelin water fraction in rodent spinal cord using T2-prepared ultrashort echo time MRI.

Authors:  Tim Klasen; Cornelius Faber
Journal:  MAGMA       Date:  2016-07-09       Impact factor: 2.310

5.  Quantitative ultrashort echo time imaging for assessment of massive iron overload at 1.5 and 3 Tesla.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

6.  Direct magnitude and phase imaging of myelin using ultrashort echo time (UTE) pulse sequences: A feasibility study.

Authors:  Qun He; Yajun Ma; Shujuan Fan; Hongda Shao; Vipul Sheth; Graeme M Bydder; Jiang Du
Journal:  Magn Reson Imaging       Date:  2017-02-20       Impact factor: 2.546

7.  Formalin tissue fixation biases myelin-sensitive MRI.

Authors:  Alan C Seifert; Melissa Umphlett; Marco Hefti; Mary Fowkes; Junqian Xu
Journal:  Magn Reson Med       Date:  2019-05-24       Impact factor: 4.668

8.  Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI.

Authors:  Neville D Gai; Ashkan A Malayeri; David A Bluemke
Journal:  MAGMA       Date:  2017-03-10       Impact factor: 2.310

9.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

10.  Rapid measurement of brain macromolecular proton fraction with transient saturation transfer MRI.

Authors:  Peter van Gelderen; Xu Jiang; Jeff H Duyn
Journal:  Magn Reson Med       Date:  2016-06-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.