Shu-Juan Fan1, Yajun Ma1, Eric Y Chang1,2, Graeme M Bydder1, Jiang Du1.   

Abstract

Inversion recovery ultrashort echo time (IR-UTE) imaging holds the potential to directly characterize MR signals from ultrashort T2 tissue components (STCs), such as collagen in cartilage and myelin in brain. The application of IR-UTE for myelin imaging has been challenging because of the high water content in brain and the possibility that the ultrashort T2 * signals are contaminated by water protons, including those associated with myelin sheaths. This study investigated such a possibility in an ovine brain D2 O exchange model and explored the potential of IR-UTE imaging for the quantification of ultrashort T2 * signals in both white and gray matter at 3 T. Six specimens were examined before and after sequential immersion in 99.9% D2 O. Long T2 MR signals were measured using a clinical proton density-weighted fast spin echo (PD-FSE) sequence. IR-UTE images were first acquired with different inversion times to determine the optimal inversion time to null the long T2 signals (TInull ). Then, at this TInull , images with echo times (TEs) of 0.01-4 ms were acquired to measure the T2 * values of STCs. The PD-FSE signal dropped to near zero after 24 h of immersion in D2 O. A wide range of TInull values were used at different time points (240-330 ms for white matter and 320-350 ms for gray matter at TR = 1000 ms) because the T1 values of the long T2 tissue components changed significantly. The T2 * values of STCs were 200-300 μs in both white and gray matter (comparable with the values obtained from myelin powder and its mixture with D2 O or H2 O), and showed minimal changes after sequential immersion. The ultrashort T2 * signals seen on IR-UTE images are unlikely to be from water protons as they are exchangeable with deuterons in D2 O. The source is more likely to be myelin itself in white matter, and might also be associated with other membranous structures in gray matter.
Copyright © 2017 John Wiley & Sons, Ltd.

Entities:  

Keywords:  T2*; gray matter; inversion recovery ultrashort echo time imaging; inversion time; myelin; white matter

Mesh:

Substances:

Year:  2017        PMID: 28731616      PMCID: PMC5617132          DOI: 10.1002/nbm.3767

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  28 in total

1.  Compartmental study of T(1) and T(2) in rat brain and trigeminal nerve in vivo.

Authors:  Mark D Does; John C Gore
Journal:  Magn Reson Med       Date:  2002-02       Impact factor: 4.668

2.  Characterization of the NMR behavior of white matter in bovine brain.

Authors:  T A Bjarnason; I M Vavasour; C L L Chia; A L MacKay
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

3.  Half radiofrequency pulse excitation with a dedicated prescan to correct eddy current effect and gradient delay.

Authors:  Takayuki Abe
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

4.  Effects of inversion time on inversion recovery prepared ultrashort echo time (IR-UTE) imaging of bound and pore water in cortical bone.

Authors:  Shihong Li; Lanqing Ma; Eric Y Chang; Hongda Shao; Jun Chen; Christine B Chung; Graeme M Bydder; Jiang Du
Journal:  NMR Biomed       Date:  2014-10-28       Impact factor: 4.044

5.  Effects of magnetization transfer on T1 contrast in human brain white matter.

Authors:  Peter van Gelderen; Xu Jiang; Jeff H Duyn
Journal:  Neuroimage       Date:  2015-12-24       Impact factor: 6.556

6.  Insights into brain microstructure from the T2 distribution.

Authors:  Alex MacKay; Cornelia Laule; Irene Vavasour; Thorarin Bjarnason; Shannon Kolind; Burkhard Mädler
Journal:  Magn Reson Imaging       Date:  2006-03-20       Impact factor: 2.546

Review 7.  MRI in multiple sclerosis: current status and future prospects.

Authors:  Rohit Bakshi; Alan J Thompson; Maria A Rocca; Daniel Pelletier; Vincent Dousset; Frederik Barkhof; Matilde Inglese; Charles R G Guttmann; Mark A Horsfield; Massimo Filippi
Journal:  Lancet Neurol       Date:  2008-07       Impact factor: 44.182

8.  Gleaning multicomponent T1 and T2 information from steady-state imaging data.

Authors:  Sean C L Deoni; Brian K Rutt; Tarunya Arun; Carlo Pierpaoli; Derek K Jones
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

9.  Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner.

Authors:  Jiang Du; Guolin Ma; Shihong Li; Michael Carl; Nikolaus M Szeverenyi; Scott VandenBerg; Jody Corey-Bloom; Graeme M Bydder
Journal:  Neuroimage       Date:  2013-11-02       Impact factor: 6.556

10.  Quantitative magnetic resonance of postmortem multiple sclerosis brain before and after fixation.

Authors:  Klaus Schmierer; Claudia A M Wheeler-Kingshott; Daniel J Tozer; Phil A Boulby; Harold G Parkes; Tarek A Yousry; Francesco Scaravilli; Gareth J Barker; Paul S Tofts; David H Miller
Journal:  Magn Reson Med       Date:  2008-02       Impact factor: 4.668

View more
  7 in total

1.  Inversion recovery UTE based volumetric myelin imaging in human brain using interleaved hybrid encoding.

Authors:  Hyungseok Jang; Yajun Ma; Adam C Searleman; Michael Carl; Jody Corey-Bloom; Eric Y Chang; Jiang Du
Journal:  Magn Reson Med       Date:  2019-09-18       Impact factor: 4.668

2.  Ultrashort echo time (UTE) magnetic resonance imaging of myelin: technical developments and challenges.

Authors:  Ya-Jun Ma; Hyungseok Jang; Eric Y Chang; Annie Hiniker; Brian P Head; Roland R Lee; Jody Corey-Bloom; Graeme M Bydder; Jiang Du
Journal:  Quant Imaging Med Surg       Date:  2020-06

3.  Improved volumetric myelin imaging in human brain using 3D dual echo inversion recovery-prepared UTE with complex echo subtraction.

Authors:  Hyungseok Jang; Zhao Wei; Mei Wu; Ya-Jun Ma; Eric Y Chang; Jody Corey-Bloom; Jiang Du
Journal:  Magn Reson Med       Date:  2019-11-20       Impact factor: 4.668

4.  Myelin Imaging in Human Brain Using a Short Repetition Time Adiabatic Inversion Recovery Prepared Ultrashort Echo Time (STAIR-UTE) MRI Sequence in Multiple Sclerosis.

Authors:  Ya-Jun Ma; Hyungseok Jang; Zhao Wei; Zhenyu Cai; Yanping Xue; Roland R Lee; Eric Y Chang; Graeme M Bydder; Jody Corey-Bloom; Jiang Du
Journal:  Radiology       Date:  2020-08-11       Impact factor: 11.105

5.  Longitudinal evaluation of demyelinated lesions in a multiple sclerosis model using ultrashort echo time magnetization transfer (UTE-MT) imaging.

Authors:  Caroline Guglielmetti; Tanguy Boucneau; Peng Cao; Annemie Van der Linden; Peder E Z Larson; Myriam M Chaumeil
Journal:  Neuroimage       Date:  2019-12-04       Impact factor: 6.556

6.  Brain ultrashort T2 component imaging using a short TR adiabatic inversion recovery prepared dual-echo ultrashort TE sequence with complex echo subtraction (STAIR-dUTE-ES).

Authors:  Ya-Jun Ma; Hyungseok Jang; Zhao Wei; Mei Wu; Eric Y Chang; Jody Corey-Bloom; Graeme M Bydder; Jiang Du
Journal:  J Magn Reson       Date:  2020-12-28       Impact factor: 2.229

7.  Inversion recovery zero echo time (IR-ZTE) imaging for direct myelin detection in human brain: a feasibility study.

Authors:  Hyungseok Jang; Michael Carl; Yajun Ma; Adam C Searleman; Saeed Jerban; Eric Y Chang; Jody Corey-Bloom; Jiang Du
Journal:  Quant Imaging Med Surg       Date:  2020-05
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.