Literature DB >> 24179420

Does decreasing the frequency of changing intravenous administration sets (>24 h) increase the incidence of sepsis in neonates receiving total parenteral nutrition?

Nevart Chirinian1, Vibhuti Shah.   

Abstract

BACKGROUND: The optimal timing for changing intravenous (IV) administration sets that contain total parenteral nutrition (TPN), with and without lipids, in neonates remains unknown.
OBJECTIVE: To determine whether decreasing the frequency of changing IV administration sets (>24 h versus every 24 h) in neonates increases the incidence of sepsis within seven days of discontinuation of TPN and microbial contamination of the infusate.
METHODS: The databases searched to identify studies that evaluated the frequency of IV administration sets on sepsis and microbial contamination of the infusate included MEDLINE, EMBASE, CINAHL, Cochrane Library, Scopus and Web of Science. The Evidence Evaluation Worksheet adapted from the American Heart Association's International Liaison Committee on Resuscitation was used to evaluate eligible studies for quality, level of evidence and direction of support.
RESULTS: Two studies were reviewed; however, neither of the studies reported on the outcome of sepsis. One study reported that changing IV administration sets every 48 h did not increase the rate of infusate (amino acid or lipid) contamination compared with change every 24 h, while the other study reported an increase in the lipid infusate contamination rate when IV administration sets were changed every 72 h.
CONCLUSIONS: There is insufficient evidence to support or refute routinely changing IV administration sets every 48 h or that decreasing the frequency of set changes increases the incidence of sepsis.

Entities:  

Keywords:  IV administration sets; IV infusion; IV tubing; Infant-newborn; Sepsis

Year:  2012        PMID: 24179420      PMCID: PMC3496353     

Source DB:  PubMed          Journal:  Paediatr Child Health        ISSN: 1205-7088            Impact factor:   2.253


  23 in total

1.  New catheters decrease nosocomial infections.

Authors:  E A McConnell
Journal:  Nurs Manage       Date:  2000-06

Review 2.  Infection control issues in central venous catheter care.

Authors:  Chris Theaker
Journal:  Intensive Crit Care Nurs       Date:  2004-12-08       Impact factor: 3.072

Review 3.  Neonatal intravenous therapy.

Authors:  S Duck
Journal:  J Intraven Nurs       Date:  1997 May-Jun

Review 4.  Peripherally inserted central venous catheters.

Authors:  M A Ryder
Journal:  Nurs Clin North Am       Date:  1993-12       Impact factor: 1.208

5.  A randomized trial of 72- versus 24-hour intravenous tubing set changes in newborns receiving lipid therapy.

Authors:  A G Matlow; I Kitai; H Kirpalani; N H Chapman; M Corey; M Perlman; P Pencharz; S Jewell; C Phillips-Gordon; R Summerbell; E L Ford-Jones
Journal:  Infect Control Hosp Epidemiol       Date:  1999-07       Impact factor: 3.254

6.  Safety of prolonging peripheral cannula and i.v. tubing use from 72 hours to 96 hours.

Authors:  K K Lai
Journal:  Am J Infect Control       Date:  1998-02       Impact factor: 2.918

7.  Effect of 24-hour intravenous tubing set change on the sterility of repackaged fat emulsion in neonates.

Authors:  Pamela D Reiter; Janie Robles; Elaine B Dowell
Journal:  Ann Pharmacother       Date:  2004-08-24       Impact factor: 3.154

8.  Effect of plastic catheter material on bacterial adherence and viability.

Authors:  G Lopez-Lopez; A Pascual; E J Perea
Journal:  J Med Microbiol       Date:  1991-06       Impact factor: 2.472

9.  Nationwide epidemic of septicemia caused by contaminated intravenous products. I. Epidemiologic and clinical features.

Authors:  D G Maki; F S Rhame; D C Mackel; J V Bennett
Journal:  Am J Med       Date:  1976-04       Impact factor: 4.965

10.  Intravenous tubing containing burettes can be safely changed at 72 hour intervals.

Authors:  D R Snydman; M Donnelly-Reidy; L K Perry; W J Martin
Journal:  Infect Control       Date:  1987-03