Literature DB >> 1905357

Effect of plastic catheter material on bacterial adherence and viability.

G Lopez-Lopez1, A Pascual, E J Perea.   

Abstract

The kinetics of adherence of single isolates of Staphylococcus aureus, S. epidermidis, Pseudomonas aeruginosa and Escherichia coli to catheters made of polyvinyl chloride (PVC), Teflon, siliconised latex, polyurethane and Vialon was evaluated by a radiometric assay. Radiolabelled bacteria (10(8) cfu/ml) were incubated in vials containing 1-cm lengths of catheter for up to 3 days. The peak of maximal adherence to each biomaterial was reached after 24 h for P. aeruginosa and after 72 h for the other strains. Bacterial adherence to PVC and siliconised latex was significantly higher (2-6 times; p less than 0.05) than to the other biomaterials for all the strains. The lowest values of adherence were observed with polyurethane and Vialon for the staphylococci but with Teflon for E. coli and P. aeruginosa. Bacterial viability and growth was evaluated in eluates obtained from incubation of segments of each catheter in buffer for 24 h. None of the eluates affected the viability of the staphylococci. However, all of them, significantly increased the growth of E. coli and P. aeruginosa with the exception of the eluate from siliconised latex, in which the inoculum count was reduced to an undetectable level for E. coli. We conclude that bacterial adherence to catheters may depend in part on the nature of the biomaterial and that certain substances eluted from the catheters may affect the viability and growth of different micro-organisms.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1905357     DOI: 10.1099/00222615-34-6-349

Source DB:  PubMed          Journal:  J Med Microbiol        ISSN: 0022-2615            Impact factor:   2.472


  15 in total

Review 1.  Arterial Catheterization and Infection: Toll-like Receptors in Defense against Microorganisms and Therapeutic Implications.

Authors:  Zakary J Hambsch; Mitchell J Kerfeld; Daniel R Kirkpatrick; Dan M McEntire; Mark D Reisbig; Charles F Youngblood; Devendra K Agrawal
Journal:  Clin Transl Sci       Date:  2015-08-14       Impact factor: 4.689

Review 2.  Does decreasing the frequency of changing intravenous administration sets (>24 h) increase the incidence of sepsis in neonates receiving total parenteral nutrition?

Authors:  Nevart Chirinian; Vibhuti Shah
Journal:  Paediatr Child Health       Date:  2012-11       Impact factor: 2.253

3.  Activity of glycopeptides in combination with amikacin or rifampin against Staphylococcus epidermidis biofilms on plastic catheters.

Authors:  A Pascual; E Ramirez de Arellano; E J Perea
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-06       Impact factor: 3.267

4.  Sigma factor RpoN employs a dual transcriptional regulation for controlling twitching motility and biofilm formation in Lysobacter enzymogenes OH11.

Authors:  Sen Han; Danyu Shen; Yun Zhao; Dan Xu; Jing Liu; Shan-Ho Chou; Fengquan Liu; Guoliang Qian
Journal:  Curr Genet       Date:  2017-10-24       Impact factor: 3.886

5.  Plasmonic photoreactors-coated plastic tubing as combined-active-and-passive antimicrobial flow sterilizer.

Authors:  Xingda An; Ronghai Cheng; Pinghua Liu; Björn M Reinhard
Journal:  J Mater Chem B       Date:  2022-03-23       Impact factor: 7.571

6.  In vitro studies of pharmacodynamic properties of vancomycin against Staphylococcus aureus and Staphylococcus epidermidis.

Authors:  E Löwdin; I Odenholt; O Cars
Journal:  Antimicrob Agents Chemother       Date:  1998-10       Impact factor: 5.191

7.  The effect of electrical currents and tobramycin on Pseudomonas aeruginosa biofilms.

Authors:  J Jass; J W Costerton; H M Lappin-Scott
Journal:  J Ind Microbiol       Date:  1995-09

Review 8.  Ureteral stent technology: Drug-eluting stents and stent coatings.

Authors:  Luo Yang; Samantha Whiteside; Peter A Cadieux; John D Denstedt
Journal:  Asian J Urol       Date:  2015-09-21

9.  Biofilm formation on three different endotracheal tubes: a prospective clinical trial.

Authors:  Hulda R Thorarinsdottir; Thomas Kander; Anna Holmberg; Sarunas Petronis; Bengt Klarin
Journal:  Crit Care       Date:  2020-06-29       Impact factor: 9.097

Review 10.  Clinical review: complications and risk factors of peripheral arterial catheters used for haemodynamic monitoring in anaesthesia and intensive care medicine.

Authors:  Bernd Scheer; Azriel Perel; Ulrich J Pfeiffer
Journal:  Crit Care       Date:  2002-04-18       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.