Literature DB >> 24166577

Time-resolved angiography using inflow subtraction (TRAILS).

Daniel Kopeinigg1, Roland Bammer.   

Abstract

PURPOSE: A novel pseudo-continuous arterial spin labeling based angiographic method called Time-Resolved Angiography using InfLow Subtraction is introduced and used to acquire time-resolved whole-head angiographic data sets in healthy volunteers in a clinical feasible scan time of less than 5 min.
METHODS: Using this new method, in conjunction with a sliding window reconstruction, a temporal resolution of 7.2 ms with a low temporal footprint of 432 ms can be achieved.
RESULTS: Excellent vessel delineation compared to a time-of-flight MRA was demonstrated. Normal variations of the vascular system including the Circle of Willis (CoW) were identified using Time-Resolved Angiography Using Inflow Subtraction. Signal intensities were measured in various vascular segments to quantify the blood transit time.
CONCLUSION: In this feasibility study, we showed that Time-Resolved Angiography using InfLow Subtraction can be used to acquire hemodynamic information of the whole head in healthy volunteers with a high temporal and spatial resolution. Further studies in patients that suffer from vascular diseases to explore various flow patterns including longer transit time are needed.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  4D; MRA; SPGR; angiography; arterial spin labeling; noncontrast enhanced; noninvasive; time resolved

Mesh:

Substances:

Year:  2013        PMID: 24166577      PMCID: PMC4396866          DOI: 10.1002/mrm.24985

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  32 in total

1.  Vessel-encoded dynamic magnetic resonance angiography using arterial spin labeling.

Authors:  Thomas W Okell; Michael A Chappell; Mark W Woolrich; Matthias Günther; David A Feinberg; Peter Jezzard
Journal:  Magn Reson Med       Date:  2010-09       Impact factor: 4.668

2.  Array compression for MRI with large coil arrays.

Authors:  Martin Buehrer; Klaas P Pruessmann; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2007-06       Impact factor: 4.668

3.  Nonenhanced ECG-gated time-resolved 4D steady-state free precession (SSFP) MR angiography (MRA) for assessment of cerebral collateral flow: comparison with digital subtraction angiography (DSA).

Authors:  Rotem Shlomo Lanzman; Patric Kröpil; Peter Schmitt; Xiaoming Bi; Michael Gliem; Falk R Miese; Daniel Hänggi; Marcel Kamp; Axel Scherer; Bernd Turowski; Dirk Blondin
Journal:  Eur Radiol       Date:  2011-01-12       Impact factor: 5.315

4.  Projection angiograms of blood labeled by adiabatic fast passage.

Authors:  W T Dixon; L N Du; D D Faul; M Gado; S Rossnick
Journal:  Magn Reson Med       Date:  1986-06       Impact factor: 4.668

5.  Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography.

Authors:  R R Edelman; B Siewert; M Adamis; J Gaa; G Laub; P Wielopolski
Journal:  Magn Reson Med       Date:  1994-02       Impact factor: 4.668

6.  Noncontrast dynamic MRA in intracranial arteriovenous malformation (AVM), comparison with time of flight (TOF) and digital subtraction angiography (DSA).

Authors:  Songlin Yu; Lirong Yan; Yuqiang Yao; Shuo Wang; Mingqi Yang; Bo Wang; Yan Zhuo; Lin Ai; Xinyuan Miao; Jizong Zhao; Danny J J Wang
Journal:  Magn Reson Imaging       Date:  2012-04-20       Impact factor: 2.546

7.  Neurologic complications of cerebral angiography. A retrospective study of complication rate and patient risk factors.

Authors:  A M Leffers; A Wagner
Journal:  Acta Radiol       Date:  2000-05       Impact factor: 1.990

8.  Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography.

Authors:  Parmede Vakil; Sameer A Ansari; Michael C Hurley; Himanshu Bhat; H Hunt Batjer; Bernard R Bendok; Christopher S Eddleman; Timothy J Carroll
Journal:  J Magn Reson Imaging       Date:  2012-02-22       Impact factor: 4.813

9.  Intravenous digital subtraction angiography: an index of collateral cerebral blood flow in internal carotid artery occlusion.

Authors:  I Awad; J R Little; M T Modic; A J Furlan
Journal:  Stroke       Date:  1982 Jul-Aug       Impact factor: 7.914

Review 10.  Gadolinium-based contrast agents and nephrogenic systemic fibrosis: a systematic review and meta-analysis.

Authors:  Rajender Agarwal; Steven M Brunelli; Kendal Williams; Matthew D Mitchell; Harold I Feldman; Craig A Umscheid
Journal:  Nephrol Dial Transplant       Date:  2008-10-24       Impact factor: 5.992

View more
  11 in total

1.  Highly accelerated vessel-selective arterial spin labeling angiography using sparsity and smoothness constraints.

Authors:  S Sophie Schauman; Mark Chiew; Thomas W Okell
Journal:  Magn Reson Med       Date:  2019-09-19       Impact factor: 4.668

Review 2.  Arterial spin labeling for the measurement of cerebral perfusion and angiography.

Authors:  Peter Jezzard; Michael A Chappell; Thomas W Okell
Journal:  J Cereb Blood Flow Metab       Date:  2017-11-23       Impact factor: 6.200

3.  Whole-brain arteriography and venography: Using improved velocity-selective saturation pulse trains.

Authors:  Wenbo Li; Feng Xu; Michael Schär; Jing Liu; Taehoon Shin; Yansong Zhao; Peter C M van Zijl; Bruce A Wasserman; Ye Qiao; Qin Qin
Journal:  Magn Reson Med       Date:  2017-08-10       Impact factor: 4.668

4.  Vascular territorial segmentation and volumetric blood flow measurement using dynamic contrast enhanced magnetic resonance angiography of the brain.

Authors:  Oren Geri; Shelly I Shiran; Jonathan Roth; Moran Artzi; Liat Ben-Sira; Dafna Ben Bashat
Journal:  J Cereb Blood Flow Metab       Date:  2017-04-10       Impact factor: 6.200

5.  Combined angiography and perfusion using radial imaging and arterial spin labeling.

Authors:  Thomas W Okell
Journal:  Magn Reson Med       Date:  2018-07-19       Impact factor: 4.668

6.  Acceleration of vessel-selective dynamic MR Angiography by pseudocontinuous arterial spin labeling in combination with Acquisition of ConTRol and labEled images in the Same Shot (ACTRESS).

Authors:  Yuriko Suzuki; Thomas W Okell; Noriyuki Fujima; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2018-12-02       Impact factor: 4.668

7.  Off-resonance correction for pseudo-continuous arterial spin labeling using the optimized encoding scheme.

Authors:  Eleanor S K Berry; Peter Jezzard; Thomas W Okell
Journal:  Neuroimage       Date:  2019-05-31       Impact factor: 6.556

Review 8.  Intracranial 3D and 4D MR Angiography Using Arterial Spin Labeling: Technical Considerations.

Authors:  Yuriko Suzuki; Noriyuki Fujima; Matthias J P van Osch
Journal:  Magn Reson Med Sci       Date:  2019-11-22       Impact factor: 2.471

9.  Optimization of 4D vessel-selective arterial spin labeling angiography using balanced steady-state free precession and vessel-encoding.

Authors:  Thomas W Okell; Peter Schmitt; Xiaoming Bi; Michael A Chappell; Rob H N Tijssen; Fintan Sheerin; Karla L Miller; Peter Jezzard
Journal:  NMR Biomed       Date:  2016-04-13       Impact factor: 4.044

10.  Evaluation of Intracranial Vasculatures in Healthy Subjects with Arterial-Spin-Labeling-Based 4D-MR Angiography at 3T.

Authors:  Yasuhiko Iryo; Toshinori Hirai; Masanobu Nakamura; Machiko Tateishi; Eri Hayashida; Minako Azuma; Shinichiro Nishimura; Mika Kitajima; Yasuyuki Yamashita
Journal:  Magn Reson Med Sci       Date:  2015-12-22       Impact factor: 2.471

View more