Literature DB >> 19643220

The service life of implant-retained overdenture attachment systems.

Monica Nogueira Pigozzo1, Marcelo Ferraz Mesquita, Guilherme Elias Pessanha Henriques, Luis Geraldo Vaz.   

Abstract

STATEMENT OF PROBLEM: Implant-retained overdentures are a treatment option for patients who are not satisfied with conventional complete dentures. Although implant-retained overdentures are widely used, little data are available or provided by implant manufacturers about retentive strength and wear of attachments.
PURPOSE: The purpose of this study was to evaluate retentive strength and fatigue resistance of 4 overdenture bar-and-clip attachment systems.
MATERIAL AND METHODS: Forty bar-and-clip attachment system specimens were tested (n=10): Conexão Bar Clip (polymer clip), Sterngold Hader Bar (polymer clip), 3i Gold Hader Type Clip (metal clip), or SIN Clipo (metal clip). Specimens immersed in artificial saliva were tested to 5500 cycles at 0.8 Hz using a servohydraulic universal testing machine. Retention strength values (N) were recorded initially and after 1100, 2200, 3300, 4400, and 5500 insertion and removal cycles during the tensile test using a speed of 1 mm/min and a load cell of 1 kN. Data were submitted to a 2-way repeated-measures ANOVA and the Tukey A post hoc test (alpha = .05).
RESULTS: An increase in retention strength values was observed during the fatigue test after 5500 cycles of insertion and removal. No significant difference in retentive strength was observed in the groups using polymer clips (Conexão Bar Clip and Sterngold Hader Bar) (P=.729); the same occurred with metal clip systems (SIN Clipo and 3i Gold Hader Type Clip) (P=.068). The SIN Clipo system demonstrated the smallest retention strength values, which were significantly different from the other 2 attachment systems, the Sterngold Hader Bar (P<.01) and the Conexão Bar Clip (P<.01). Although the 3i Gold Hader Type Clip did not differ significantly, in terms of retentive strength, from the Sterngold Hader Bar (P=.258), its retentive strength was significantly lower than the retentive strength of the Conexão Bar Clip system (P=.030).
CONCLUSIONS: The systems evaluated demonstrated satisfactory retention for all time periods tested, as retention strengths from 5 to 7 N should be sufficient to stabilize overdentures. No component fracture or compromise in retention was found for any of the systems tested.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19643220     DOI: 10.1016/S0022-3913(09)60112-8

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  12 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Hader bar and clip attachment retained mandibular complete denture.

Authors:  Kunwarjeet Singh; Nidhi Gupta; Vikram Kapoor; Ridhimaa Gupta
Journal:  BMJ Case Rep       Date:  2013-10-21

Review 3.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

4.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

5.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

6.  Comparative Evaluation of Retentive Properties of Two Compatible Ball Attachments in Mandibular Implant-Retained Overdentures: An In Vitro Study.

Authors:  Maryam Memarian; Simindokht Zarrati; Sedigheh Karimi; Mehran Bahrami
Journal:  J Dent (Tehran)       Date:  2018-03

7.  In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System.

Authors:  Tae-Yun Kang; Jee-Hwan Kim; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Materials (Basel)       Date:  2019-11-16       Impact factor: 3.623

8.  How the initial retentive force of implant-supported overdentures can be affected with splinted and unsplinted attachments systems.

Authors:  Farahnaz Nejatidanesh; Omid Savabi; Ghazal Savabi; Mehdi Razavi
Journal:  Dent Res J (Isfahan)       Date:  2021-12-10

9.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

10.  In vitro retention capacity of two overdenture attachment systems: Locator® and Equator®.

Authors:  Nieves Mínguez-Tomás; Jorge Alonso-Pérez-Barquero; Lucía Fernández-Estevan; Ángel Vicente-Escuder; Eduardo J Selva-Otaolaurruchi
Journal:  J Clin Exp Dent       Date:  2018-07-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.