Literature DB >> 24142027

Radiolabelled leucocyte scintigraphy versus conventional radiological imaging for the management of late, low-grade vascular prosthesis infections.

P A Erba1, G Leo, M Sollini, C Tascini, R Boni, R N Berchiolli, F Menichetti, M Ferrari, E Lazzeri, G Mariani.   

Abstract

PURPOSE: In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods.
METHODS: All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months.
RESULTS: (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%).
CONCLUSION: (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive radiological findings. (99m)Tc-HMPAO-WBC SPECT/CT might be used to optimize patient management.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24142027     DOI: 10.1007/s00259-013-2582-9

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  37 in total

Review 1.  Treatment of infections associated with surgical implants.

Authors:  Rabih O Darouiche
Journal:  N Engl J Med       Date:  2004-04-01       Impact factor: 91.245

2.  A consensus protocol for white blood cells labelling with technetium-99m hexamethylpropylene amine oxime. International Society of Radiolabeled Blood Elements (ISORBE)

Authors:  M Roca; J Martín-Comín; W Becker; M Bernardo-Filho; B Gutfilen; A Moisan; M Peters; E Prats; M Rodrigues; C Sampson; A Signore; H Sinzinger; M Thakur
Journal:  Eur J Nucl Med       Date:  1998-07

3.  99mTc-WBC scintigraphy with SPECT/CT in the evaluation of arterial graft infection.

Authors:  Lawrence Lou; Karim N Alibhai; Gerrit B Winkelaar; Robert G Turnbull; Michael E Hoskinson; Robert Warshawski; Ho Jen; Jonathan T Abele
Journal:  Nucl Med Commun       Date:  2010-05       Impact factor: 1.690

4.  Aortoenteric fistula and perigraft infection: evaluation with CT.

Authors:  R N Low; S D Wall; R B Jeffrey; R A Sollitto; L M Reilly; L M Tierney
Journal:  Radiology       Date:  1990-04       Impact factor: 11.105

5.  Detection of aortic graft infection by fluorodeoxyglucose positron emission tomography: comparison with computed tomographic findings.

Authors:  Kazuki Fukuchi; Yoshio Ishida; Masahiro Higashi; Tomohiro Tsunekawa; Hitoshi Ogino; Kenji Minatoya; Keisuke Kiso; Hiroaki Naito
Journal:  J Vasc Surg       Date:  2005-11       Impact factor: 4.268

6.  In vivo detection of Staphylococcus aureus in biofilm on vascular prostheses using non-invasive biophotonic imaging.

Authors:  U Lorenz; T Schäfer; K Ohlsen; G C Tiurbe; C Bühler; C-T Germer; R Kellersmann
Journal:  Eur J Vasc Endovasc Surg       Date:  2010-10-12       Impact factor: 7.069

7.  Redo aortic grafting after treatment of aortic graft infection.

Authors:  P J DiMuzio; L M Reilly; R J Stoney
Journal:  J Vasc Surg       Date:  1996-09       Impact factor: 4.268

8.  FDG-PET for the detection of infected vascular grafts.

Authors:  Z Keidar; S Nitecki
Journal:  Q J Nucl Med Mol Imaging       Date:  2009-02       Impact factor: 2.346

9.  Natural history of periprosthetic air on computerized axial tomographic examination of the abdomen following abdominal aortic aneurysm repair.

Authors:  P J O'Hara; G P Borkowski; N R Hertzer; P B O'Donovan; S L Brigham; E G Beven
Journal:  J Vasc Surg       Date:  1984-05       Impact factor: 4.268

10.  Computerized tomographic assessment of graft incorporation after aortic reconstruction.

Authors:  P G Qvarfordt; L M Reilly; A S Mark; J Goldstone; S D Wall; W K Ehrenfeld; R J Stoney
Journal:  Am J Surg       Date:  1985-08       Impact factor: 2.565

View more
  14 in total

1.  How useful is 18F-FDG PET/CT in patients with suspected vascular graft infection?

Authors:  Jean-François Sarrazin; Mikaël Trottier; Michel Tessier
Journal:  J Nucl Cardiol       Date:  2018-07-25       Impact factor: 5.952

Review 2.  Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area.

Authors:  Takeshiro Fujii; Yoshinori Watanabe
Journal:  Ann Thorac Cardiovasc Surg       Date:  2015-09-08       Impact factor: 1.520

Review 3.  Small Molecule Sensors Targeting the Bacterial Cell Wall.

Authors:  Matthew F L Parker; Robert R Flavell; Justin M Luu; Oren S Rosenberg; Michael A Ohliger; David M Wilson
Journal:  ACS Infect Dis       Date:  2020-06-09       Impact factor: 5.084

Review 4.  Alternative Nuclear Imaging Tools for Infection Imaging.

Authors:  Paola Anna Erba; Francesco Bartoli; Martina Sollini; Berchiolli Raffaella; Roberta Zanca; Esposito Enrica; Elena Lazzeri
Journal:  Curr Cardiol Rep       Date:  2022-06-13       Impact factor: 3.955

5.  Diagnostic yield of 18F-FDG PET/CT in suspected diagnosis of vascular graft infection: A prospective cohort study.

Authors:  Hans Bowles; Juan Ambrosioni; Gaspar Mestres; Marta Hernández-Meneses; Nuria Sánchez; Jaime Llopis; Xavier Yugueros; Manel Almela; Asunción Moreno; Vicenç Riambau; David Fuster; Jose M Miró
Journal:  J Nucl Cardiol       Date:  2018-06-15       Impact factor: 5.952

6.  Added Value of Dual-Time-Point 18F-FDG PET/CT With Delayed Imaging for Detecting Aortic Graft Infection: An Observational Study.

Authors:  Chih-Yung Chang; Cheng-Pei Chang; Chun-Che Shih; Bang-Hung Yang; Cheng-Yi Cheng; Chi-Wei Chang; Lee-Shing Chu; Shyh-Jen Wang; Ren-Shyan Liu
Journal:  Medicine (Baltimore)       Date:  2015-07       Impact factor: 1.889

Review 7.  Current Applications for Nuclear Medicine Imaging in Pulmonary Disease.

Authors:  Joanna E Kusmirek; Josiah D Magnusson; Scott B Perlman
Journal:  Curr Pulmonol Rep       Date:  2020-07-22

Review 8.  Two decades of SPECT/CT - the coming of age of a technology: An updated review of literature evidence.

Authors:  Ora Israel; O Pellet; L Biassoni; D De Palma; E Estrada-Lobato; G Gnanasegaran; T Kuwert; C la Fougère; G Mariani; S Massalha; D Paez; F Giammarile
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-07-04       Impact factor: 9.236

9.  Prosthetic vascular graft infection: A systematic review and meta-analysis on diagnostic accuracy of 18FDG PET/CT.

Authors:  Zohre Mahmoodi; Morteza Salarzaei; Mahboobeh Sheikh
Journal:  Gen Thorac Cardiovasc Surg       Date:  2021-07-26

Review 10.  Preclinical studies and prospective clinical applications for bacteria-targeted imaging: the future is bright.

Authors:  Marjolein Heuker; Anna Gomes; Jan Maarten van Dijl; Gooitzen M van Dam; Alexander W Friedrich; Bhanu Sinha; Marleen van Oosten
Journal:  Clin Transl Imaging       Date:  2016-07-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.