PURPOSE: In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. METHODS: All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. RESULTS: (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%). CONCLUSION: (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive radiological findings. (99m)Tc-HMPAO-WBC SPECT/CT might be used to optimize patient management.
PURPOSE: In this study we evaluated the diagnostic performance of (99m)Tc-HMPAO-leucocyte ((99m)Tc-HMPAO-WBC) scintigraphy in a consecutive series of 55 patients (46 men and 9 women, mean age 71 ± 9 years, range 50 - 88 years) with a suspected late or a low-grade late vascular prosthesis infection (VPI), also comparing the diagnostic accuracy of WBC with that of other radiological imaging methods. METHODS: All patients suspected of having VPI underwent clinical examination, blood tests, microbiology, US and CT, and were classified according to the Fitzgerald criteria. A final diagnosis of VPI was established in 47 of the 55 patients, with microbiological confirmation after surgical removal of the prosthesis in 36 of the 47. In the 11 patients with major contraindications to surgery, the final diagnosis was based on microbiology and clinical follow-up of at least 18 months. RESULTS: (99m)Tc-HMPAO-WBC planar, SPECT and SPECT/CT imaging identified VPI in 43 of 47 patients (20 of these also showed infection at extra-prosthetic sites). In the remaining eight patients without VPI, different sites of infections were found. The use of SPECT/CT images led to a significant reduction in the number of false-positive findings in 37% of patients (sensitivity and specificity 100 %, versus 85.1% and 62.5% for stand-alone SPECT). Sensitivity and specificity were 34% and 75% for US, 48.9% and 83.3% for CT, and 68.1% and 62.5% for the FitzGerald classification. Perioperative mortality was 5.5%, mid-term mortality 12%, and long-term mortality 27%. Survival rates were similar in patients treated with surgery and antimicrobial therapy compared to patients treated with antimicrobial therapy alone (61% versus 63%, respectively), while infection eradication at 12 months was significantly higher following surgery (83.3% versus 45.5%). CONCLUSION: (99m)Tc-HMPAO-WBC SPECT/CT is useful for detecting, localizing and defining the extent of graft infection in patients with late and low-grade late VPI with inconclusive radiological findings. (99m)Tc-HMPAO-WBC SPECT/CT might be used to optimize patient management.
Authors: M Roca; J Martín-Comín; W Becker; M Bernardo-Filho; B Gutfilen; A Moisan; M Peters; E Prats; M Rodrigues; C Sampson; A Signore; H Sinzinger; M Thakur Journal: Eur J Nucl Med Date: 1998-07
Authors: Lawrence Lou; Karim N Alibhai; Gerrit B Winkelaar; Robert G Turnbull; Michael E Hoskinson; Robert Warshawski; Ho Jen; Jonathan T Abele Journal: Nucl Med Commun Date: 2010-05 Impact factor: 1.690
Authors: U Lorenz; T Schäfer; K Ohlsen; G C Tiurbe; C Bühler; C-T Germer; R Kellersmann Journal: Eur J Vasc Endovasc Surg Date: 2010-10-12 Impact factor: 7.069
Authors: Matthew F L Parker; Robert R Flavell; Justin M Luu; Oren S Rosenberg; Michael A Ohliger; David M Wilson Journal: ACS Infect Dis Date: 2020-06-09 Impact factor: 5.084
Authors: Paola Anna Erba; Francesco Bartoli; Martina Sollini; Berchiolli Raffaella; Roberta Zanca; Esposito Enrica; Elena Lazzeri Journal: Curr Cardiol Rep Date: 2022-06-13 Impact factor: 3.955
Authors: Ora Israel; O Pellet; L Biassoni; D De Palma; E Estrada-Lobato; G Gnanasegaran; T Kuwert; C la Fougère; G Mariani; S Massalha; D Paez; F Giammarile Journal: Eur J Nucl Med Mol Imaging Date: 2019-07-04 Impact factor: 9.236
Authors: Marjolein Heuker; Anna Gomes; Jan Maarten van Dijl; Gooitzen M van Dam; Alexander W Friedrich; Bhanu Sinha; Marleen van Oosten Journal: Clin Transl Imaging Date: 2016-07-16