Abstract

OBJECTIVE: Radionuclide imaging with fluorodeoxyglucose (FDG) and positron emission tomography (PET) has been proposed for the identification of vascular graft infection; however, its accuracy has not been determined. We performed this prospective study to compare the usefulness of FDG-PET in the assessment of vascular graft infection relative to computed tomography (CT).
METHODS: FDG-PET was performed for 33 consecutive patients with a suspected arterial prosthetic graft infection. The PET images were then assessed visually in terms of the density of uptake. In cases with positive uptake, the pattern of accumulation was also defined, such as focal or diffuse uptake. We compared the diagnostic efficiency of PET with contemporaneous CT in detection of infection of the arterial prosthetic graft.
RESULTS: On the basis of the surgical, microbiological, and clinical follow-up findings, the aortic grafts were considered infected in 11 patients and not infected in 22 patients. Although the sensitivity of PET (91%) was higher than that of CT (64%), its specificity (64%) was lower than that of CT (86%). When focal uptake was set as the positive criterion in FDG, the specificity and positive predictive value of PET for the diagnosis of aortic graft infection improved significantly to 95% (P < .05 for both).
CONCLUSIONS: Although both techniques are useful in evaluation of patients with suspected aortic graft infection, using the characteristic FDG uptake pattern described previously as a diagnostic criterion made the efficacy of FDG superior to that of CT in the diagnostic assessment of patients with suspected aortic graft infection.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16275448     DOI: 10.1016/j.jvs.2005.07.038

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  38 in total

1.  Inflammatory F-18 fluorodeoxyglucose uptake over arterial bypass prosthesis seen on positron emission tomography can predict acute vascular events.

Authors:  Michèle Duet; Jean Pierre Laissy; Benoit Paulmier; Patrick Rossignol; Frédéric Bernard; Nadia Ghazzar-Pierquet; Marc Faraggi
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

2.  Conservative management of Candida infection of prosthetic aortic graft by means of caspofungin and fluconazole alone.

Authors:  Lukas J Motloch; Dennis Rottlaender; Turak Darabi; Insa Joost; Erland Erdmann; Uta C Hoppe
Journal:  Tex Heart Inst J       Date:  2011

3.  Diagnostics of "non-acute" vascular prosthesis infection using 18F-FDG PET/CT: our experience with 96 prostheses.

Authors:  M Spacek; O Belohlavek; J Votrubova; P Sebesta; P Stadler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-12-24       Impact factor: 9.236

Review 4.  [Chronic abdominal aortic graft infection : Detection with 18F-FDG-PET/CT].

Authors:  K Kilk; A Hyhlik-Dürr; A Afshar-Oromieh; D Böckler
Journal:  Chirurg       Date:  2010-07       Impact factor: 0.955

5.  The role of FDG PET/CT in therapy control of aortic graft infection.

Authors:  Lars Husmann; Bruno Ledergerber; Alexia Anagnostopoulos; Paul Stolzmann; Bert-Ram Sah; Irene A Burger; Roxana Pop; Alberto Weber; Dieter Mayer; Zoran Rancic; Barbara Hasse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-06-11       Impact factor: 9.236

6.  Comparing diagnostic accuracy of 18F-FDG-PET/CT, contrast enhanced CT and combined imaging in patients with suspected vascular graft infections.

Authors:  Lars Husmann; Martin W Huellner; Bruno Ledergerber; Alexia Anagnostopoulos; Paul Stolzmann; Bert-Ram Sah; Irene A Burger; Zoran Rancic; Barbara Hasse
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-11-13       Impact factor: 9.236

7.  Textural features of 18F-fluorodeoxyglucose positron emission tomography scanning in diagnosing aortic prosthetic graft infection.

Authors:  Ben R Saleem; Roelof J Beukinga; Ronald Boellaard; Andor W J M Glaudemans; Michel M P J Reijnen; Clark J Zeebregts; Riemer H J A Slart
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-12-24       Impact factor: 9.236

8.  Diagnostic yield of 18F-FDG PET/CT in suspected diagnosis of vascular graft infection: A prospective cohort study.

Authors:  Hans Bowles; Juan Ambrosioni; Gaspar Mestres; Marta Hernández-Meneses; Nuria Sánchez; Jaime Llopis; Xavier Yugueros; Manel Almela; Asunción Moreno; Vicenç Riambau; David Fuster; Jose M Miró
Journal:  J Nucl Cardiol       Date:  2018-06-15       Impact factor: 5.952

Review 9.  Role of modern imaging techniques for diagnosis of infection in the era of 18F-fluorodeoxyglucose positron emission tomography.

Authors:  Rakesh Kumar; Sandip Basu; Drew Torigian; Vivek Anand; Hongming Zhuang; Abass Alavi
Journal:  Clin Microbiol Rev       Date:  2008-01       Impact factor: 26.132

10.  [Endovascular aortic surgery: management of secondary aortobronchial and aorto-enteral fistulas].

Authors:  A Hyhlik-Dürr; P Geisbüsch; M Hakimi; T F Weber; A Schaible; D Böckler
Journal:  Chirurg       Date:  2009-10       Impact factor: 0.955