Literature DB >> 15519345

A new method for estimating joint parameters from motion data.

Michael H Schwartz1, Adam Rozumalski.   

Abstract

Joint centers and axes of rotation (joint parameters) are central to all branches of movement analysis. In gait analysis, the standard protocol used to determine hip and knee joint parameters is prone to errors arising from palpation, anthropometric regression equations, and misplaced alignment devices. Several alternative methods have been proposed, but to date none have been shown to be accurate and reliable enough for use in the clinical setting. This article describes a new method for joint parameter estimation. The new method can be summarized as follows: (i) the motions of two adjacent segments spanning a single joint are tracked, (ii) the axis of rotation between every pair of observed segment configurations is computed, (iii) the most likely intersection of all axes (effective joint center) and most likely orientation of the axes (effective joint axis) is found. Initial validation of the method was conducted on a hinged mechanical analog and a single healthy adult subject. For the analog, the center was found to be within 3.8 mm of the geometric center and 2.0 degrees of the geometric axis (standard deviation). For the adult subject, hip centers varied on the order of 1-3 mm, knee centers by 3-9 mm, and knee axes by 2.0 degrees. The results suggest that the new method is an objective, precise, and practical alternative to the standard clinical approach.

Mesh:

Year:  2005        PMID: 15519345     DOI: 10.1016/j.jbiomech.2004.03.009

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  73 in total

1.  Proximal and distal kinematics in female runners with patellofemoral pain.

Authors:  Brian Noehren; Michael B Pohl; Zack Sanchez; Tom Cunningham; Christian Lattermann
Journal:  Clin Biomech (Bristol, Avon)       Date:  2011-11-08       Impact factor: 2.063

2.  Subject-Specific Axes of Rotation Based on Talar Morphology Do Not Improve Predictions of Tibiotalar and Subtalar Joint Kinematics.

Authors:  Jennifer A Nichols; Koren E Roach; Niccolo M Fiorentino; Andrew E Anderson
Journal:  Ann Biomed Eng       Date:  2017-06-21       Impact factor: 3.934

3.  3D inverse dynamics in non-orthonormal segment coordinate system.

Authors:  R Dumas; L Chèze
Journal:  Med Biol Eng Comput       Date:  2007-01-25       Impact factor: 2.602

4.  Effects of step length, age, and fall history on hip and knee kinetics and knee co-contraction during the maximum step length test.

Authors:  Brian W Schulz; Manutchanok Jongprasithporn; Stephanie J Hart-Hughes; Tatjana Bulat
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-08-08       Impact factor: 2.063

5.  Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination.

Authors:  I Parel; A G Cutti; A Kraszewski; G Verni; H Hillstrom; A Kontaxis
Journal:  Med Biol Eng Comput       Date:  2013-10-18       Impact factor: 2.602

6.  Muscular coordination of knee motion during the terminal-swing phase of normal gait.

Authors:  Allison S Arnold; Darryl G Thelen; Michael H Schwartz; Frank C Anderson; Scott L Delp
Journal:  J Biomech       Date:  2007-06-18       Impact factor: 2.712

7.  Relationship between physical impairments and movement patterns during gait in patients with end-stage hip osteoarthritis.

Authors:  Joseph Zeni; Federico Pozzi; Sumayah Abujaber; Laura Miller
Journal:  J Orthop Res       Date:  2014-12-09       Impact factor: 3.494

8.  Knee kinematics is altered post-fatigue while performing a crossover task.

Authors:  Nelson Cortes; Eric Greska; Jatin P Ambegaonkar; Roger O Kollock; Shane V Caswell; James A Onate
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-09-18       Impact factor: 4.342

9.  In-vivo quantification of dynamic hip joint center errors and soft tissue artifact.

Authors:  Niccolo M Fiorentino; Penny R Atkins; Michael J Kutschke; K Bo Foreman; Andrew E Anderson
Journal:  Gait Posture       Date:  2016-09-11       Impact factor: 2.840

10.  Do novice runners have weak hips and bad running form?

Authors:  Anne Schmitz; Kelsey Russo; Lauren Edwards; Brian Noehren
Journal:  Gait Posture       Date:  2014-03-04       Impact factor: 2.840

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.