Clinical evaluation of a multifocal aspheric diffractive intraocular lens.

Stefanie Schmickler1, Carlos Palomino Bautista, Frank Goes, Sunil Shah, James S Wolffsohn.   

Abstract

AIM: To evaluate the performance of an aspheric diffractive multifocal acrylic intraocular lens (IOL), ZMB00 1-Piece Tecnis.
SETTING: Five sites across Europe.
METHODS: Fifty-two patients with cataracts (average age 68.5±10.5 years, 35 female) were bilaterally implanted with the aspheric diffractive multifocal IOL after completing a questionnaire regarding their optical visual symptoms, use of visual correction and their visual satisfaction. The questionnaire was completed again 4-6 months after surgery along with measures of uncorrected and best-corrected distance and near visual acuity, under photopic and mesopic lighting, reading ability, defocus curve testing and ocular examination for adverse events.
RESULTS: The residual refractive error was 0.01±0.47D with 56% of eyes within ±0.25D and 97% within ±1.0D. Uncorrected visual acuity was 0.02±0.10logMAR at distance and 0.15±0.30 logMAR at near, only reducing to 0.07±0.10logMAR at distance and 0.21±0.25logMAR at near in mesopic conditions.The defocus curve showed a near addition between 2.5-3.0 D allowing a reading acuity of 0.08±0.13 logMAR, with a range of clear vision <0.3 logMAR of ∼4.0 D. The average reading speed was 121.4±30.8 words per minute. Spectacle independence was 100% for distance and 88% for near, with high levels of satisfaction reported. Overall rating of vision without glasses could be explained (r=0.760) by preoperative best-corrected distance acuity, postoperative reading acuity and postoperative uncorrected distance acuity in photopic conditions (p<0.001). Only two minor adverse events occurred.
CONCLUSIONS: The ZMB00 1-Piece Tecnis multifocal IOL provides a good visual outcome at distance and near with minimal adverse effects.

Entities:  

Keywords:  Lens and zonules; Optics and Refraction; Treatment Surgery

Mesh:

Year:  2013        PMID: 24123903     DOI: 10.1136/bjophthalmol-2013-304010

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  18 in total

1.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

Review 2.  Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review.

Authors:  Wei Du; Wei Lou; Qiang Wu
Journal:  Int J Ophthalmol       Date:  2019-11-18       Impact factor: 1.779

3.  Clinical outcomes of a new diffractive multifocal intraocular lens.

Authors:  Baha Toygar; Ozge Yabas Kiziloglu; Okan Toygar; Ali Murat Hacimustafaoglu
Journal:  Int J Ophthalmol       Date:  2017-12-18       Impact factor: 1.779

4.  Visual outcomes of multifocal intraocular lens implantation in patients with cataract and high hyperopia and patient selection.

Authors:  Servet Cetinkaya; Zeynep Dadaci; Nursen Oncel Acir; Yasemin Fatma Cetinkaya; Halil Ibrahim Yener; Muammer Ozcimen
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

5.  Bilateral Implantation of a New Refractive Multi-Segmented Multifocal Intraocular Lens in Cataract or Refractive Lens Exchange Patients.

Authors:  Mike P Holzer; Rudy M M A Nuijts; Soraya M R Jonker; Erik L J G Mertens; Asim Bozkurt Sener; Jorge A O Cazal; Antoni Salvador Playa; Ramon Ruiz Mesa; Bettina C Thomas
Journal:  Clin Ophthalmol       Date:  2021-05-21

6.  Visual outcomes and patient satisfaction after refractive lens exchange with a single-piece diffractive multifocal intraocular lens.

Authors:  John S M Chang; Jack C M Ng; Vincent K C Chan; Antony K P Law
Journal:  J Ophthalmol       Date:  2014-11-23       Impact factor: 1.909

7.  Visual Outcomes, Patient Satisfaction and Spectacle Independence with a Trifocal Diffractive Intraocular Lens.

Authors:  Florian Tobias Alwin Kretz; Chul Young Choi; Matthias Müller; Matthias Gerl; Ralf Helmar Gerl; Gerd Uwe Auffarth
Journal:  Korean J Ophthalmol       Date:  2016-05-18

8.  Visual acuity and patient satisfaction at varied distances and lighting conditions after implantation of an aspheric diffractive multifocal one-piece intraocular lens.

Authors:  Daniel H Chang
Journal:  Clin Ophthalmol       Date:  2016-08-03

9.  Usefulness of Implantation of Diffractive Multifocal Intraocular Lens in Eyes with Long Axial Lengths.

Authors:  Tomoichiro Ogawa; Takuya Shiba; Hiroshi Tsuneoka
Journal:  J Ophthalmol       Date:  2015-11-01       Impact factor: 1.909

10.  Evaluation of Different Power of Near Addition in Two Different Multifocal Intraocular Lenses.

Authors:  Ugur Unsal; Gonen Baser
Journal:  J Ophthalmol       Date:  2016-06-01       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.