Literature DB >> 24119249

Release of contaminants from a heterogeneously fractured low permeability unit underlying a DNAPL source zone.

R A Dearden1, D J Noy, M R Lelliott, R Wilson, G P Wealthall.   

Abstract

The invasion of DNAPL into fractured low permeability deposits results in the formation of secondary source zones that represent a long-term source of VOCs to adjacent aquifers. We present data from a site underlain by a fractured mudstone contaminated with TCE DNAPL that was poised for release following remediation of the overlying aquifer. Observations of contaminant distributions and fracture networks from the site and a nearby mudstone exposure respectively, enabled prediction of the imminent aquifer recontamination. The fractures, likely formed by gypsum dissolution, were characterised by fracture apertures and spacings that ranged from 0.01 to 49 mm and 0.047 to 3.37 m (10th and 90th percentile values) respectively. Numerical model results show that prediction of outward mass flux in the first year was highly variable (8 to 32 g/m²/d for an initial constant concentration with depth profile) and dependent on both the fracture spacing and aperture and the contaminant distribution. However after 1 year, assuming a heterogeneous distribution of fractures, mass flux was predictable within a narrow range of values (at 20 years; 0.04-0.08 g/m²/d). Similar results were obtained from more typical fracture networks with spacings of 0.1 to 0.5 m and apertures of 10 to 100 μm. These results suggest that when considering potential recontamination in a bounding aquifer, fracture characterisation may not be necessary and instead the focus should be on determining the surface area contributing contaminant mass to an aquifer, the contaminant concentration depth profiles, the hydraulic properties of the receiving aquifer and the elapsed time since aquifer remediation.
Copyright © 2011 NERC. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Back diffusion; DNAPL; Fracture; Non-NAPL source zone; Secondary source zone

Mesh:

Substances:

Year:  2011        PMID: 24119249     DOI: 10.1016/j.jconhyd.2011.05.006

Source DB:  PubMed          Journal:  J Contam Hydrol        ISSN: 0169-7722            Impact factor:   3.188


  4 in total

1.  Reactive Transport Simulation of Fracture Channelization and Transmissivity Evolution.

Authors:  Hang Deng; Catherine A Peters
Journal:  Environ Eng Sci       Date:  2019-01-18       Impact factor: 1.907

2.  The impact of well-field configuration and permeability heterogeneity on contaminant mass removal and plume persistence.

Authors:  Zhilin Guo; Mark L Brusseau
Journal:  J Hazard Mater       Date:  2017-03-08       Impact factor: 10.588

3.  Modeling groundwater contaminant transport in the presence of large heterogeneity: A case study comparing MT3D and RWhet.

Authors:  Zhilin Guo; Graham E Fogg; Mark L Brusseau; Eric M LaBolle; Jose Lopez
Journal:  Hydrogeol J       Date:  2019-02-15       Impact factor: 3.178

4.  The Impact of Well-Field Configuration on Contaminant Mass Removal and Plume Persistence for Homogeneous versus Layered Systems.

Authors:  Zhilin Guo; Mark L Brusseau
Journal:  Hydrol Process       Date:  2017-11-07       Impact factor: 3.565

  4 in total