Literature DB >> 24114112

A measure for characterizing sliding on lung boundaries.

Ryan E Amelon1, Kunlin Cao, Joseph M Reinhardt, Gary E Christensen, Madhavan L Raghavan.   

Abstract

The lobes of the lung slide relative to each other during breathing. Quantifying lobar sliding can aid in better understanding lung function, better modeling of lung dynamics, and for studying phenomenon such as pleural adhesion. We propose a novel measure to characterize lobe sliding in the lung based on the displacement field obtained from image registration of CT scans. When two sliding lobes are modeled as a continuum, the discontinuity in the displacement field at the fissure will manifest as elevated maximum shear--the proposed measure--which is capable of capturing both the level and orientation of sliding. Six human lungs were analyzed using scans spanning functional residual capacity to total lung capacity. The lung lobes were segmented and registered on a lobe-by-lobe basis to obtain the displacement field from which the proposed sliding measure was calculated. The sliding measure was found to be insignificant in the parenchyma, as relatively little tissue shear occurs here. On the other hand, it was elevated along the fissures. Thus, a map of the proposed sliding measure of the entire lung clearly delineates and quantifies sliding between lung lobes. Sliding is a key aspect of lung deformation during breathing. The proposed measure may help resolve artifacts introduced by sliding in deformation analysis techniques used for radiotherapy.

Entities:  

Mesh:

Year:  2013        PMID: 24114112      PMCID: PMC3943475          DOI: 10.1007/s10439-013-0920-5

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  12 in total

1.  Direct measurement of lung motion using hyperpolarized helium-3 MR tagging.

Authors:  Jing Cai; G Wilson Miller; Talissa A Altes; Paul W Read; Stanley H Benedict; Eduard E de Lange; Gordon D Cates; James R Brookeman; John P Mugler; Ke Sheng
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-04-18       Impact factor: 7.038

2.  Mass preserving nonrigid registration of CT lung images using cubic B-spline.

Authors:  Youbing Yin; Eric A Hoffman; Ching-Long Lin
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

3.  Results of a multi-institution deformable registration accuracy study (MIDRAS).

Authors:  Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-11-10       Impact factor: 7.038

4.  Regional ventilation during spontaneous breathing and mechanical ventilation in dogs.

Authors:  R D Hubmayr; J R Rodarte; B J Walters; F M Tonelli
Journal:  J Appl Physiol (1985)       Date:  1987-12

5.  Evaluation of lobar biomechanics during respiration using image registration.

Authors:  Kai Ding; Youbing Yin; Kunlin Cao; Gary E Christensen; Ching-Long Lin; Eric A Hoffman; Joseph M Reinhardt
Journal:  Med Image Comput Comput Assist Interv       Date:  2009

6.  Three-dimensional characterization of regional lung deformation.

Authors:  Ryan Amelon; Kunlin Cao; Kai Ding; Gary E Christensen; Joseph M Reinhardt; Madhavan L Raghavan
Journal:  J Biomech       Date:  2011-07-28       Impact factor: 2.712

7.  Anatomy-guided lung lobe segmentation in X-ray CT images.

Authors:  Soumik Ukil; Joseph M Reinhardt
Journal:  IEEE Trans Med Imaging       Date:  2009-02       Impact factor: 10.048

8.  Dynamic MRI of grid-tagged hyperpolarized helium-3 for the assessment of lung motion during breathing.

Authors:  Jing Cai; Ke Sheng; Stanley H Benedict; Paul W Read; James M Larner; John P Mugler; Eduard E de Lange; Gordon D Cates; G Wilson Miller
Journal:  Int J Radiat Oncol Biol Phys       Date:  2009-06-18       Impact factor: 7.038

9.  Patient-specific finite element modeling of respiratory lung motion using 4D CT image data.

Authors:  René Werner; Jan Ehrhardt; Rainer Schmidt; Heinz Handels
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

10.  Regional lung strain in dogs during deflation from total lung capacity.

Authors:  J R Rodarte; R D Hubmayr; D Stamenovic; B J Walters
Journal:  J Appl Physiol (1985)       Date:  1985-01
View more
  4 in total

1.  Discontinuity Preserving Liver MR Registration with 3D Active Contour Motion Segmentation.

Authors:  Dongxiao Li; Wenxiong Zhong; Kofi M Deh; Thanh Nguyen; Martin R Prince; Yi Wang; Pascal Spincemaille
Journal:  IEEE Trans Biomed Eng       Date:  2018-11-12       Impact factor: 4.538

2.  Supervoxels for Graph Cuts-Based Deformable Image Registration Using Guided Image Filtering.

Authors:  Adam Szmul; Bartłomiej W Papież; Andre Hallack; Vicente Grau; Julia A Schnabel
Journal:  J Electron Imaging       Date:  2017-10-04       Impact factor: 0.945

3.  The Intrapleural Bridge Connection is One of the Reasons for Unknown Localized Pleural Adhesion.

Authors:  Qihua Gu; Xinhao Deng; Zhao Li; Jing Wang; Chengping Hu; Shuhua Lei; Xiaoling Cai
Journal:  Int J Gen Med       Date:  2021-04-20

4.  Geodesic density regression for correcting 4DCT pulmonary respiratory motion artifacts.

Authors:  Wei Shao; Yue Pan; Oguz C Durumeric; Joseph M Reinhardt; John E Bayouth; Mirabela Rusu; Gary E Christensen
Journal:  Med Image Anal       Date:  2021-06-21       Impact factor: 13.828

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.