During low-flow manually-controlled anaesthesia (MCA) the anaesthetist needs constantly adjust end-tidal oxygen (EtO2) and anaesthetic concentrations (EtAA) to assure an adequate and safe anaesthesia. Recently introduced anaesthetic machines can automatically maintain those variables at target values, avoiding the burden on the anaesthetist. End-tidal-controlled anaesthesia (EtCA) and MCA provided by the same anaesthetic machine under the same fresh gas flow were compared. Eighty patients were prospectively observed: in MCA group (n = 40) target end-tidal sevoflurane (1%) and EtO2 concentrations (≥ 35%) were manually controlled by the anaesthetist. In EtCA group (n = 40) the same anaesthetic machine with an additional end-tidal control feature was used to reach the same targets, rendering automatic the achievement and maintenance of those targets. Anaesthetic machine characteristics, amount of consumed gases, oxygen and sevoflurane efficiencies, and the amount of interventions by the anaesthetist were recorded. In EtCA group EtAA was achieved later (145 s) than in MCA (71 s) and remained controlled thereafter. Even though the target expired gas fractions were achieved faster in MCA, manual adjustments were required throughout anaesthesia for both oxygen and sevoflurane. In MCA patients the number of manual adjustments to stabilize EtAA and EtO2 were 137 and 107, respectively; no adjustment was required in EtCA. Low-flow anaesthesia delivered with an anaesthetic machine able to automatically control EtAA and EtO2 provided the same clinical stability and avoided the continuous manual adjustment of delivered sevoflurane and oxygen concentrations. Hence, the anaesthetist could dedicate more time to the patient and operating room activities.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24114079     DOI: 10.1007/s10877-013-9516-8

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Tutorial: context-sensitive decrement times for inhaled anesthetics.

Authors:  Edmond I Eger; Steven L Shafer
Journal:  Anesth Analg       Date:  2005-09       Impact factor: 5.108

2.  Changing patterns in anesthetic fresh gas flow rates over 5 years in a teaching hospital.

Authors:  R Ross Kennedy; Richard A French
Journal:  Anesth Analg       Date:  2008-05       Impact factor: 5.108

3.  Low and minimal flow inhalational anaesthesia.

Authors:  A D Baxter
Journal:  Can J Anaesth       Date:  1997-06       Impact factor: 5.063

4.  Context-sensitive half-times and other decrement times of inhaled anesthetics.

Authors:  J M Bailey
Journal:  Anesth Analg       Date:  1997-09       Impact factor: 5.108

5.  Financial and environmental costs of manual versus automated control of end-tidal gas concentrations.

Authors:  S Tay; L Weinberg; P Peyton; D Story; J Briedis
Journal:  Anaesth Intensive Care       Date:  2013-01       Impact factor: 1.669

Review 6.  Low flow and economics of inhalational anaesthesia.

Authors:  I Odin; P Feiss
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2005-09

7.  Model-based automatic feedback control versus human control of end-tidal isoflurane concentration using low-flow anaesthesia.

Authors:  T J Sieber; C W Frei; M Derighetti; P Feigenwinter; D Leibundgut; A M Zbinden
Journal:  Br J Anaesth       Date:  2000-12       Impact factor: 9.166

8.  The effects of fentanyl on sevoflurane requirements for loss of consciousness and skin incision.

Authors:  T Katoh; K Ikeda
Journal:  Anesthesiology       Date:  1998-01       Impact factor: 7.892

9.  Sevoflurane requirements for tracheal intubation with and without fentanyl.

Authors:  T Katoh; Y Nakajima; G Moriwaki; S Kobayashi; A Suzuki; T Iwamoto; H Bito; K Ikeda
Journal:  Br J Anaesth       Date:  1999-04       Impact factor: 9.166

10.  Assessing the clinical or pharmaco-economical benefit of target controlled desflurane delivery in surgical patients using the Zeus anaesthesia machine.

Authors:  B Lortat-Jacob; V Billard; W Buschke; F Servin
Journal:  Anaesthesia       Date:  2009-11       Impact factor: 6.955

View more
  2 in total

1.  New technology in anaesthesia: friend or foe?

Authors:  R Ross Kennedy
Journal:  J Clin Monit Comput       Date:  2014-04       Impact factor: 2.502

2.  Target-Controlled Inhalational Anesthesia-Isoflurane Consumption with Adequacy of Anesthesia Monitoring in Conventional and Multimodal Analgesia - A Comparative Study.

Authors:  Reshma Vithayathil; Keelara Shivalingaiah Savitha; Nischala Dixit; Litty John
Journal:  Anesth Essays Res       Date:  2022-07-18
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.