Literature DB >> 24113852

Effect of defibrillation threshold testing-induced ventricular fibrillation on renal function.

John H Shin1, Chotikorn Khunnawat, Jose Baez-Escudero, Bradley P Knight, John F Beshai.   

Abstract

INTRODUCTION: The effect of defibrillation threshold (DFT) testing with induction of ventricular fibrillation (VF) on renal function is currently unknown. This study examined the acute effect of DFT testing on renal function in patients undergoing implantable cardioverter defibrillator (ICD) implantation. METHODS AND
RESULTS: We performed a prospective cohort study of 148 consecutive patients who underwent ICD implantation from January 1, 2007 to May 30, 2008. Patients were assigned to one of two cohorts: a DFT group who underwent DFT testing at device implantation and a no-DFT group that was not tested. Baseline and 24-h postprocedure renal function were assessed with measurements of serum creatinine and estimated glomerular filtration rate (GFR) by the Modified Diet in Renal Disease equation. Changes in serum creatinine and estimated GFR were compared between cohorts. Ninety-eight patients (66%) underwent DFT testing (average VF induction count, 1.5 ± 0.9; mean VF duration, 10 ± 4 s). Fifty patients (34%) were not tested. Patients in the no-DFT group had lower mean left ventricular ejection fraction, higher New York Heart Association class, higher atrial fibrillation incidence, and greater intravenous contrast utilization at device implant. Baseline and postprocedure serum creatinine values were similar between groups (baseline, 1.25 ± 0.45 mg/dL; post-ICD, 1.26 ± 0.5 mg/dL). Baseline GFR was lower in the DFT cohort (55.2 ± 18.8 mL/min/BSA vs 63.7 ± 22.7 mL/min/BSA, p = 0.023). No significant differences between groups were observed in the mean change in serum creatinine or estimated GFR.
CONCLUSIONS: DFT testing at the time of ICD implantation is not associated with acute adverse effects on renal function.

Entities:  

Mesh:

Year:  2013        PMID: 24113852     DOI: 10.1007/s10840-013-9840-4

Source DB:  PubMed          Journal:  J Interv Card Electrophysiol        ISSN: 1383-875X            Impact factor:   1.900


  24 in total

1.  Is defibrillation testing safe?

Authors:  I Singer; J van der Laken; H L Edmonds; A D Slater; E Austin; C B Shields; J Kupersmith
Journal:  Pacing Clin Electrophysiol       Date:  1991-11       Impact factor: 1.976

2.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

Review 3.  Acute renal failure after cardiac surgery for carcinoid heart disease: incidence, risk factors, and prognosis.

Authors:  Kevin R Regner; Heidi M Connolly; Hartzell V Schaff; Robert C Albright
Journal:  Am J Kidney Dis       Date:  2005-05       Impact factor: 8.860

4.  Defibrillation threshold testing: is it really necessary at the time of implantable cardioverter-defibrillator insertion?

Authors:  Andrea M Russo; William Sauer; Edward P Gerstenfeld; Henry H Hsia; David Lin; Joshua M Cooper; Sanjay Dixit; Ralph J Verdino; Hemal M Nayak; David J Callans; Vickas Patel; Francis E Marchlinski
Journal:  Heart Rhythm       Date:  2005-05       Impact factor: 6.343

5.  A comparison of prediction equations for estimating glomerular filtration rate in adults without kidney disease.

Authors:  Julie Lin; Eric L Knight; Mary Lou Hogan; Ajay K Singh
Journal:  J Am Soc Nephrol       Date:  2003-10       Impact factor: 10.121

6.  Mild nephrotoxicity associated with vancomycin use.

Authors:  N J Downs; R E Neihart; J M Dolezal; G R Hodges
Journal:  Arch Intern Med       Date:  1989-08

7.  Troponin T elevation after implanted defibrillator discharge predicts survival.

Authors:  D Blendea; M Blendea; J Banker; C A McPherson
Journal:  Heart       Date:  2009-04-13       Impact factor: 5.994

8.  Kidney function is related to cerebral small vessel disease.

Authors:  M Arfan Ikram; Meike W Vernooij; Albert Hofman; Wiro J Niessen; Aad van der Lugt; Monique M B Breteler
Journal:  Stroke       Date:  2007-11-29       Impact factor: 7.914

9.  Validation of the Modification of Diet in Renal Disease formula for estimating GFR with special emphasis on calibration of the serum creatinine assay.

Authors:  Stein Hallan; Arne Asberg; Morten Lindberg; Harald Johnsen
Journal:  Am J Kidney Dis       Date:  2004-07       Impact factor: 8.860

10.  Intraoperative defibrillation threshold testing during implantable cardioverter-defibrillator insertion: do we really need it?

Authors:  Valeria Calvi; Daniela Dugo; Davide Capodanno; Rocco Arancio; Angelo Di Grazia; Claudio Liotta; Euglena Puzzangara; Antonio Ragusa; Alberto Arestia; Corrado Tamburino
Journal:  Am Heart J       Date:  2010-01       Impact factor: 4.749