Literature DB >> 1721196

Is defibrillation testing safe?

I Singer1, J van der Laken, H L Edmonds, A D Slater, E Austin, C B Shields, J Kupersmith.   

Abstract

Determination of defibrillation thresholds (DFTs) and implantable cardioverter defibrillator (ICD) testing requires repeated inductions of ventricular fibrillation (VF) and defibrillation attempts using known energy outputs. Little is known about the individual and cumulative effects of repetitive brief episodes of VF and hypoperfusion on cerebral function. The potential clinical utility of quantitative electroencephalographic (QEEG) monitoring during intraoperative ICD testing, by using processed 19-channel EEG (0.5-35 Hz bandwidth), was examined in ten anesthetized patients, five males and five females (mean age 62 +/- 10 years), who underwent ICD implantation and testing. Ischemic QEEG patterns were defined as those with a 3 standard deviation increase (P less than 0.01) in absolute delta (1.5-3.5 Hz) power persisting for greater than or equal to 2.5 minutes. The majority (80%) of the VF episodes (70) were accompanied by QEEG "slowing" (doubling of the pre-VF low frequency delta waves amplitude). All the patients (5/5) experiencing greater than 6 VF episodes showed a statistically significant increase in the low frequency amplitude. In contrast, this EEG abnormality was apparent in only one of five patients experiencing less than 6 VF episodes. These results suggest a cumulative QEEG depression associated with ICD testing. QEEG may provide an objective means for establishing an individualized upper safe limit of DFT testing and the total number of induced VF episodes.

Entities:  

Mesh:

Year:  1991        PMID: 1721196     DOI: 10.1111/j.1540-8159.1991.tb02787.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  5 in total

1.  Effectiveness of VF induction with DC fibber versus conventional induction methods in patients on chronic amiodarone therapy.

Authors:  Jason C Rubenstein; Manish S Gupta; Michael H Kim
Journal:  J Interv Card Electrophysiol       Date:  2013-09-08       Impact factor: 1.900

2.  Effect of defibrillation threshold testing-induced ventricular fibrillation on renal function.

Authors:  John H Shin; Chotikorn Khunnawat; Jose Baez-Escudero; Bradley P Knight; John F Beshai
Journal:  J Interv Card Electrophysiol       Date:  2013-10-11       Impact factor: 1.900

3.  ICD implantation without intraoperative testing does not increase the rate of system modifications and does not impair defibrillation efficacy tested in follow-up.

Authors:  Dirk Bastian; Stefan Kracker; Matthias Pauschinger; Konrad Göhl
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-06-07

4.  Experience of cardioverter-defibrillators inserted without thoracotomy: evaluation of transvenously inserted intracardiac leads alone or with a subcutaneous axillary patch.

Authors:  L Jordaens; J W Trouerbach; P Vertongen; L Herregods; J Poelaert; G Van Nooten
Journal:  Br Heart J       Date:  1993-01

Review 5.  Sex Differences in Cardiovascular Disease and Cognitive Impairment: Another Health Disparity for Women?

Authors:  Annabelle Santos Volgman; C Noel Bairey Merz; Neelum T Aggarwal; Vera Bittner; T Jared Bunch; Philip B Gorelick; Pauline Maki; Hena N Patel; Athena Poppas; Jeremy Ruskin; Andrea M Russo; Shari R Waldstein; Nanette K Wenger; Kristine Yaffe; Carl J Pepine
Journal:  J Am Heart Assoc       Date:  2019-09-24       Impact factor: 5.501

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.