Literature DB >> 24111028

Design of 3-DOF force sensing micro-forceps for robot assisted vitreoretinal surgery.

Berk Gonenc, James Handa, Peter Gehlbach, Russell H Taylor, Iulian Iordachita.   

Abstract

Vitreoretinal surgery is associated with serious complications that can easily stem from excessive tissue manipulation forces while the forces required for such surgery are routinely well below human tactile sensation. Despite the critical need in this area, there is still no practical vitreoretinal instrument that can sense both the axial and transverse tool-to-tissue interaction forces with sub-mN accuracy. In this study, we present the conceptual design and optimization of a 3 degrees-of-freedom (DOF) force sensing micro-forceps as the next generation of our force sensing instruments. 4 fiber Bragg grating (FBG) strain sensors are integrated in the design to measure tool tip forces.

Entities:  

Mesh:

Year:  2013        PMID: 24111028      PMCID: PMC3971918          DOI: 10.1109/EMBC.2013.6610841

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  8 in total

1.  Sub-retinal hemorrhage during internal limiting membrane peeling for a macular hole.

Authors:  Ko Nakata; Masahito Ohji; Yasushi Ikuno; Shunji Kusaka; Fumi Gomi; Yasuo Tano
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-05-09       Impact factor: 3.117

2.  Applied force during vitreoretinal microsurgery with handheld instruments.

Authors:  Anirudha S Jagtap; Cameron N Riviere
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

3.  Micro-force sensing in robot assisted membrane peeling for vitreoretinal surgery.

Authors:  Marcin Balicki; Ali Uneri; Iulian Iordachita; James Handa; Peter Gehlbach; Russell Taylor
Journal:  Med Image Comput Comput Assist Interv       Date:  2010

4.  Iatrogenic retinal breaks complicating pars plana vitrectomy.

Authors:  J B Carter; R G Michels; B M Glaser; S De Bustros
Journal:  Ophthalmology       Date:  1990-07       Impact factor: 12.079

5.  Epiretinal membrane removal in diabetic eyes: comparison of viscodissection with conventional methods of membrane peeling.

Authors:  R A Grigorian; A Castellarin; R Fegan; C Seery; L V Del Priore; S Von Hagen; M A Zarbin
Journal:  Br J Ophthalmol       Date:  2003-06       Impact factor: 4.638

6.  Distribution of iatrogenic retinal breaks in macular hole surgery.

Authors:  R N Sjaarda; B M Glaser; J T Thompson; R P Murphy; A Hanham
Journal:  Ophthalmology       Date:  1995-09       Impact factor: 12.079

7.  Force sensing micro-forceps for robot assisted retinal surgery.

Authors:  Ismail Kuru; Berk Gonenc; Marcin Balicki; James Handa; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2012

8.  A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery.

Authors:  Iulian Iordachita; Zhenglong Sun; Marcin Balicki; Jin U Kang; Soo Jay Phee; James Handa; Peter Gehlbach; Russell Taylor
Journal:  Int J Comput Assist Radiol Surg       Date:  2009-04-15       Impact factor: 2.924

  8 in total
  7 in total

1.  Accurate real-time depth control for CP-SSOCT distal sensor based handheld microsurgery tools.

Authors:  Gyeong Woo Cheon; Yong Huang; Jaepyeng Cha; Peter L Gehlbach; Jin U Kang
Journal:  Biomed Opt Express       Date:  2015-04-30       Impact factor: 3.732

2.  Towards Robot-Assisted Vitreoretinal Surgery: Force-Sensing Micro-Forceps Integrated with a Handheld Micromanipulator.

Authors:  Berk Gonenc; Ellen Feldman; Peter Gehlbach; James Handa; Russell H Taylor; Iulian Iordachita
Journal:  IEEE Int Conf Robot Autom       Date:  2014-05

3.  3-DOF Force-Sensing Micro-Forceps for Robot-Assisted Membrane Peeling: Intrinsic Actuation Force Modeling.

Authors:  Anzhu Gao; Berk Gonenc; Jiangzhen Guo; Hao Liu; Peter Gehlbach; Iulian Iordachita
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2016-07-28

4.  Development of A Miniaturized 3-DOF Force Sensing Instrument for Robotically Assisted Retinal Microsurgery and Preliminary Results.

Authors:  Xingchi He; Peter Gehlbach; James Handa; Russell Taylor; Iulian Iordachita
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2014-08

5.  Human eye phantom for developing computer and robot-assisted epiretinal membrane peeling.

Authors:  Amrita Gupta; Berk Gonenc; Marcin Balicki; Kevin Olds; James Handa; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

6.  Force-Based Puncture Detection and Active Position Holding for Assisted Retinal Vein Cannulation.

Authors:  Berk Gonenc; Nhat Tran; Cameron N Riviere; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  IEEE SICE RSJ Int Conf Multisens Fusion Integr Intell Syst       Date:  2015-09

7.  Robot-assisted vitreoretinal surgery: current perspectives.

Authors:  Marina Roizenblatt; Thomas L Edwards; Peter L Gehlbach
Journal:  Robot Surg       Date:  2018-02-23
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.