Literature DB >> 2381696

Iatrogenic retinal breaks complicating pars plana vitrectomy.

J B Carter1, R G Michels, B M Glaser, S De Bustros.   

Abstract

To determine the current incidence and outcome of iatrogenic retinal breaks occurring during pars plana vitrectomy, the authors reviewed 404 consecutive operations done on eyes without preexisting retinal breaks. Thirteen eyes had 14 iatrogenic peripheral retinal breaks. Three other eyes had both peripheral breaks and posterior breaks. Twenty-five eyes had 43 posterior breaks. The incidence of peripheral breaks was 4% and of posterior breaks was 6%. Patients with proliferative diabetic retinopathy had a higher incidence of iatrogenic retinal breaks than those with other diagnoses. Peripheral breaks occurred most commonly just posterior to the site of insertion of the vitrectomy probe. Although six eyes required reoperation, 33 of 38 eyes had a successful anatomic outcome.

Entities:  

Mesh:

Year:  1990        PMID: 2381696     DOI: 10.1016/s0161-6420(90)32492-2

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  16 in total

1.  [Incidence and prophylaxis of retinal detachment following pars plana vitrectomy].

Authors:  M Rauber; U Mester
Journal:  Ophthalmologe       Date:  2006-08       Impact factor: 1.059

2.  Design of 3-DOF force sensing micro-forceps for robot assisted vitreoretinal surgery.

Authors:  Berk Gonenc; James Handa; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

3.  The incidence and the risk factors for iatrogenic retinal breaks during pars plana vitrectomy.

Authors:  M Dogramaci; E J K Lee; T H Williamson
Journal:  Eye (Lond)       Date:  2012-02-17       Impact factor: 3.775

4.  3-DOF Force-Sensing Micro-Forceps for Robot-Assisted Membrane Peeling: Intrinsic Actuation Force Modeling.

Authors:  Anzhu Gao; Berk Gonenc; Jiangzhen Guo; Hao Liu; Peter Gehlbach; Iulian Iordachita
Journal:  Proc IEEE RAS EMBS Int Conf Biomed Robot Biomechatron       Date:  2016-07-28

5.  Phacovitrectomy without prone posture for full thickness macular holes.

Authors:  P R Simcock; S Scalia
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

6.  Risk factors for iatrogenic retinal breaks induced by separation of posterior hyaloid face during 23-gauge pars plana vitrectomy.

Authors:  R Rahman; C D Murray; J Stephenson
Journal:  Eye (Lond)       Date:  2013-03-01       Impact factor: 3.775

7.  Evaluation of a Micro-Force Sensing Handheld Robot for Vitreoretinal Surgery.

Authors:  Berk Gonenc; Marcin A Balicki; James Handa; Peter Gehlbach; Cameron N Riviere; Russell H Taylor; Iulian Iordachita
Journal:  Rep U S       Date:  2012-12-20

Review 8.  Iatrogenic retinal traumas in ophthalmic surgery.

Authors:  Daniele Tognetto; Maria Teresa di Lauro; Daniela Fanni; Adelia Zagidullina; Luca Michelone; Giuseppe Ravalico
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-07-05       Impact factor: 3.117

9.  A Comparative Study for Robot Assisted Vitreoretinal Surgery: Micron vs. the Steady-Hand Robot.

Authors:  Berk Gonenc; James Handa; Peter Gehlbach; Russell H Taylor; Iulian Iordachita
Journal:  IEEE Int Conf Robot Autom       Date:  2013

10.  Comparison of retinal breaks observed during 23 gauge transconjunctival vitrectomy versus conventional 20 gauge surgery for proliferative diabetic retinopathy.

Authors:  Sharif A Issa; Alan Connor; Maged Habib; David Hw Steel
Journal:  Clin Ophthalmol       Date:  2011-01-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.