Literature DB >> 24089914

Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT.

Jing Wang1, Xuejun Gu.   

Abstract

PURPOSE: Image reconstruction and motion model estimation in four-dimensional cone-beam CT (4D-CBCT) are conventionally handled as two sequential steps. Due to the limited number of projections at each phase, the image quality of 4D-CBCT is degraded by view aliasing artifacts, and the accuracy of subsequent motion modeling is decreased by the inferior 4D-CBCT. The objective of this work is to enhance both the image quality of 4D-CBCT and the accuracy of motion model estimation with a novel strategy enabling simultaneous motion estimation and image reconstruction (SMEIR).
METHODS: The proposed SMEIR algorithm consists of two alternating steps: (1) model-based iterative image reconstruction to obtain a motion-compensated primary CBCT (m-pCBCT) and (2) motion model estimation to obtain an optimal set of deformation vector fields (DVFs) between the m-pCBCT and other 4D-CBCT phases. The motion-compensated image reconstruction is based on the simultaneous algebraic reconstruction technique (SART) coupled with total variation minimization. During the forward- and backprojection of SART, measured projections from an entire set of 4D-CBCT are used for reconstruction of the m-pCBCT by utilizing the updated DVF. The DVF is estimated by matching the forward projection of the deformed m-pCBCT and measured projections of other phases of 4D-CBCT. The performance of the SMEIR algorithm is quantitatively evaluated on a 4D NCAT phantom. The quality of reconstructed 4D images and the accuracy of tumor motion trajectory are assessed by comparing with those resulting from conventional sequential 4D-CBCT reconstructions (FDK and total variation minimization) and motion estimation (demons algorithm). The performance of the SMEIR algorithm is further evaluated by reconstructing a lung cancer patient 4D-CBCT.
RESULTS: Image quality of 4D-CBCT is greatly improved by the SMEIR algorithm in both phantom and patient studies. When all projections are used to reconstruct a 3D-CBCT by FDK, motion-blurring artifacts are present, leading to a 24.4% relative reconstruction error in the NACT phantom. View aliasing artifacts are present in 4D-CBCT reconstructed by FDK from 20 projections, with a relative error of 32.1%. When total variation minimization is used to reconstruct 4D-CBCT, the relative error is 18.9%. Image quality of 4D-CBCT is substantially improved by using the SMEIR algorithm and relative error is reduced to 7.6%. The maximum error (MaxE) of tumor motion determined from the DVF obtained by demons registration on a FDK-reconstructed 4D-CBCT is 3.0, 2.3, and 7.1 mm along left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. From the DVF obtained by demons registration on 4D-CBCT reconstructed by total variation minimization, the MaxE of tumor motion is reduced to 1.5, 0.5, and 5.5 mm along L-R, A-P, and S-I directions. From the DVF estimated by SMEIR algorithm, the MaxE of tumor motion is further reduced to 0.8, 0.4, and 1.5 mm along L-R, A-P, and S-I directions, respectively.
CONCLUSIONS: The proposed SMEIR algorithm is able to estimate a motion model and reconstruct motion-compensated 4D-CBCT. The SMEIR algorithm improves image reconstruction accuracy of 4D-CBCT and tumor motion trajectory estimation accuracy as compared to conventional sequential 4D-CBCT reconstruction and motion estimation.

Entities:  

Mesh:

Year:  2013        PMID: 24089914     DOI: 10.1118/1.4821099

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  26 in total

1.  4D cone-beam CT reconstruction using multi-organ meshes for sliding motion modeling.

Authors:  Zichun Zhong; Xuejun Gu; Weihua Mao; Jing Wang
Journal:  Phys Med Biol       Date:  2016-01-13       Impact factor: 3.609

2.  Principal component reconstruction (PCR) for cine CBCT with motion learning from 2D fluoroscopy.

Authors:  Hao Gao; Yawei Zhang; Lei Ren; Fang-Fang Yin
Journal:  Med Phys       Date:  2017-12-11       Impact factor: 4.071

3.  Augmentation of CBCT Reconstructed From Under-Sampled Projections Using Deep Learning.

Authors:  Zhuoran Jiang; Yingxuan Chen; Yawei Zhang; Yun Ge; Fang-Fang Yin; Lei Ren
Journal:  IEEE Trans Med Imaging       Date:  2019-04-23       Impact factor: 10.048

4.  A biomechanical modeling-guided simultaneous motion estimation and image reconstruction technique (SMEIR-Bio) for 4D-CBCT reconstruction.

Authors:  Xiaokun Huang; You Zhang; Jing Wang
Journal:  Phys Med Biol       Date:  2018-02-08       Impact factor: 3.609

5.  Real-time out-of-plane artifact subtraction tomosynthesis imaging using prior CT for scanning beam digital x-ray system.

Authors:  Meng Wu; Rebecca Fahrig
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

6.  A Biomechanical Modeling Guided CBCT Estimation Technique.

Authors:  You Zhang; Joubin Nasehi Tehrani; Jing Wang
Journal:  IEEE Trans Med Imaging       Date:  2016-11-01       Impact factor: 10.048

7.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609

8.  4D liver tumor localization using cone-beam projections and a biomechanical model.

Authors:  You Zhang; Michael R Folkert; Bin Li; Xiaokun Huang; Jeffrey J Meyer; Tsuicheng Chiu; Pam Lee; Joubin Nasehi Tehrani; Jing Cai; David Parsons; Xun Jia; Jing Wang
Journal:  Radiother Oncol       Date:  2018-11-14       Impact factor: 6.280

9.  A new scheme for real-time high-contrast imaging in lung cancer radiotherapy: a proof-of-concept study.

Authors:  Hao Yan; Zhen Tian; Yiping Shao; Steve B Jiang; Xun Jia
Journal:  Phys Med Biol       Date:  2016-03-04       Impact factor: 3.609

10.  Dosimetric verification of lung cancer treatment using the CBCTs estimated from limited-angle on-board projections.

Authors:  You Zhang; Fang-Fang Yin; Lei Ren
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.