Literature DB >> 2408197

Detection of middle cerebral artery emboli during carotid endarterectomy using transcranial Doppler ultrasonography.

M P Spencer1, G I Thomas, S C Nicholls, L R Sauvage.   

Abstract

The purpose of our study was to define the signal characteristics and clinical circumstances associated with emboli detected in the middle cerebral artery using 2-MHz pulsed transcranial Doppler ultrasound in patients undergoing carotid endarterectomy. Signals designating emboli were transients displaying harmonic qualities the signatures of which were clearly different from those of mechanical and electronic artifacts. We reviewed the audio/video tape recordings from 91 patients for signals of air bubble emboli occurring upon release of common carotid artery crossclamps; recordings from 35 patients (38%) demonstrated air bubble emboli. Transients with signatures identical to those of air bubble emboli were also discovered when bubbles in the bloodstream were improbable; we defined these transients as representing formed-element emboli. Such signals were found in recordings from 24 patients (26%), and they occurred before (both spontaneously and upon common carotid artery compression), during, and after surgical dissection. Signals indicating formed-element emboli were associated with intraluminal platelet thrombus, with ulcerations in the carotid artery, and with transient ischemic attacks or stroke. Most postoperative formed-element emboli did not cause symptoms but, when persisting for hours, they were associated with strokes and cerebral infarction. This Doppler ultrasound method of detecting emboli will be useful in the study of stroke mechanisms and as a clinical test to guide the medical and surgical treatment of patients at risk of stroke.

Entities:  

Mesh:

Year:  1990        PMID: 2408197     DOI: 10.1161/01.str.21.3.415

Source DB:  PubMed          Journal:  Stroke        ISSN: 0039-2499            Impact factor:   7.914


  27 in total

1.  Effects of myocardial contractility on microemboli production by mechanical heart valves in a bovine model.

Authors:  G Deklunder; J L Lecroart; J L Conger; D Lapeyre; I Gregoric; H Rose; D Tamez; O H Frazier
Journal:  Tex Heart Inst J       Date:  2000

Review 2.  [Proximal protection systems using carotid artery stent].

Authors:  I Q Grunwald; U Dorenbeck; C Axmann; C Roth; T Struffert; W Reith
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

3.  Transcranial Doppler ultrasonography in the detection of venous to arterial shunting in acute stroke and transient ischaemic attacks.

Authors:  M Yeung; K A Khan; A Shuaib
Journal:  J Neurol Neurosurg Psychiatry       Date:  1996-11       Impact factor: 10.154

Review 4.  Perioperative stroke. Part I: General surgery, carotid artery disease, and carotid endarterectomy.

Authors:  D H Wong
Journal:  Can J Anaesth       Date:  1991-04       Impact factor: 5.063

Review 5.  Prevalence and prognostic impact of microembolic signals in arterial sources of embolism. A systematic review of the literature.

Authors:  Martin A Ritter; Ralf Dittrich; Niels Thoenissen; E Bernd Ringelstein; Darius G Nabavi
Journal:  J Neurol       Date:  2008-05-06       Impact factor: 4.849

Review 6.  Role of transcranial Doppler ultrasonography in evaluation of patients with cerebrovascular disease.

Authors:  Vijay K Sharma; Georgios Tsivgoulis; Annabelle Y Lao; Andrei V Alexandrov
Journal:  Curr Neurol Neurosci Rep       Date:  2007-01       Impact factor: 5.081

7.  Turbulence and circulating cerebral emboli detectable at Doppler ultrasonography: a differentiation study in a stenotic middle cerebral artery model.

Authors:  Yi Yang; Donald G Grosset; Qiu Li; Ashfaq Shuaib; Kennedy R Lees
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

8.  Denoising performance of modified dual-tree complex wavelet transform for processing quadrature embolic Doppler signals.

Authors:  Gorkem Serbes; Nizamettin Aydin
Journal:  Med Biol Eng Comput       Date:  2013-09-19       Impact factor: 2.602

9.  Estimation of the size of air emboli detectable by electrical impedance measurement.

Authors:  S Nebuya; M Noshiro; B H Brown; R H Smallwood; P Milnes
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

Review 10.  Modulating thrombotic potential in catheter-based percutaneous coronary and peripheral vascular interventions.

Authors:  James L Orford; Peter B Berger
Journal:  J Thromb Thrombolysis       Date:  2004-02       Impact factor: 2.300

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.