Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients.

M Parker1, S Cawley, V Palial.   

Abstract

A consecutive series of 320 patients with an intracapsular fracture of the hip treated with a dynamic locking plate (Targon Femoral Neck (TFN)) were reviewed. All surviving patients were followed for a minimum of two years. During the follow-up period 109 patients died. There were 112 undisplaced fractures, of which three (2.7%) developed nonunion or re-displacement and five (4.5%) developed avascular necrosis of the femoral head. Revision to an arthroplasty was required for five patients (4.5%). A further six patients (5.4%) had elective removal of the plate and screws. There were 208 displaced fractures, of which 32 (15.4%) developed nonunion or re-displacement and 23 (11.1%) developed avascular necrosis. A further four patients (1.9%) developed a secondary fracture around the TFN. Revision to a hip replacement was required for 43 patients (20.7%) patients and a further seven (3.3%) had elective removal of the plate and screws. It is suggested that the stronger distal fixation combined with rotational stability may lead to a reduced incidence of complications related to the healing of the fracture when compared with other contemporary fixation devices but this needs to be confirmed in further studies.

Entities:  

Keywords:  Dynamic locking plate; Hip; Hip fracture; Internal fixation; Intracapsular hip fracture; Trauma

Mesh:

Year:  2013        PMID: 24078540     DOI: 10.1302/0301-620X.95B10.31511

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  21 in total

1.  The Targon FN system for the management of intracapsular neck of femur fractures: minimum 2-year experience and outcome in an independent hospital.

Authors:  Donald Osarumwense; Elizabeth Tissingh; Kakra Wartenberg; Saurabh Aggarwal; Fikry Ismail; Sam Orakwe; Farid Khan
Journal:  Clin Orthop Surg       Date:  2015-02-10

2.  [Femoral neck fracture].

Authors:  P Gierer; T Mittlmeier
Journal:  Unfallchirurg       Date:  2015-03       Impact factor: 1.000

Review 3.  Surgical treatment options for femoral neck fractures in the elderly.

Authors:  Boris A Zelle; Luis M Salazar; Shain L Howard; Kisan Parikh; Hans-Christoph Pape
Journal:  Int Orthop       Date:  2022-02-21       Impact factor: 3.075

Review 4.  Avascular Necrosis of Femoral Head-Overview and Current State of the Art.

Authors:  Wojciech Konarski; Tomasz Poboży; Andrzej Śliwczyński; Ireneusz Kotela; Jan Krakowiak; Martyna Hordowicz; Andrzej Kotela
Journal:  Int J Environ Res Public Health       Date:  2022-06-15       Impact factor: 4.614

5.  The provision of total hip replacement for displaced intracapsular hip fractures.

Authors: 
Journal:  Ann R Coll Surg Engl       Date:  2016-01-07       Impact factor: 1.891

6.  [Joint-preserving treatment of medial femoral neck fractures with an angular stable implant].

Authors:  M Saß; T Mittlmeier
Journal:  Oper Orthop Traumatol       Date:  2016-05-03       Impact factor: 1.154

7.  The Telescoping Hip Plate for Treatment of Femoral Neck Fracture: Design Rationale, Surgical Technique and Early Results.

Authors:  Michael Willey; Matthew L Welsh; Travis S Roth; Kenneth J Koval; James V Nepola
Journal:  Iowa Orthop J       Date:  2018

8.  Outcomes of internal fixation of intracapsular hip fractures using dynamic locking plate system (Targon® FN).

Authors:  Hosam E Matar; Prakash Chandran
Journal:  J Orthop       Date:  2018-08-16

9.  Dynamic locking plate vs. cannulated cancellous screw for displaced intracapsular hip fracture: A comparative study.

Authors:  Yaniv Warschawski; Tal Frenkel Rutenberg; Shai Factor; Adirian Tudor; Zachary Sharfman; Samuel Morgan; Adi Lichtenstein; Nimrod Snir
Journal:  J Orthop       Date:  2021-02-12

10.  Outcomes after fixation for undisplaced femoral neck fracture compared to hemiarthroplasty for displaced femoral neck fracture among the elderly.

Authors:  Jeff Chien-Fu Lin; Wen-Miin Liang
Journal:  BMC Musculoskelet Disord       Date:  2015-08-19       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.