Literature DB >> 25729515

The Targon FN system for the management of intracapsular neck of femur fractures: minimum 2-year experience and outcome in an independent hospital.

Donald Osarumwense1, Elizabeth Tissingh1, Kakra Wartenberg1, Saurabh Aggarwal1, Fikry Ismail1, Sam Orakwe1, Farid Khan1.   

Abstract

BACKGROUND: The Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture complications. We wished to see if these results can be reproduced in an independent institution.
METHODS: The records of consecutive patients, treated with this implant between 2008 and 2011 at Queen Elizabeth Hospital, were identified and collected for this study. Operations were performed by all grades of surgeons under supervision as appropriate. These patients went on to have both clinical and radiological assessment for fracture healing and function.
RESULTS: Fifty-one patients were identified with 43 patients available for final follow-up. The average age was 66 years with a minimum follow-up of 24 months. A non-union rate of 0% in the undisplaced fracture group and 1 in 12 (8%) in the displaced fracture group was observed. An avascular necrosis rate of 6% and 8% was observed for undisplaced and displaced fracture types, respectively. No significant change in premorbid to postoperative ambulation was observed and there was no wound complication.
CONCLUSIONS: Our study shows similar results with those of the design centre and which are superior to those currently found in the literature for the more traditional fixation methods. It also shows that the promising results with this new implant as seen from the design institutions can be reproduced by all cadres of surgeons in non-specialist practice.

Entities:  

Keywords:  Bone nails; Fracture fixation; Neck femur

Mesh:

Year:  2015        PMID: 25729515      PMCID: PMC4329529          DOI: 10.4055/cios.2015.7.1.22

Source DB:  PubMed          Journal:  Clin Orthop Surg        ISSN: 2005-291X


  8 in total

1.  Biomechanical analysis of the sliding hip screw, cannulated screws and Targon1 FN in intracapsular hip fractures in cadaver femora.

Authors:  Erwin Brandt; Nico Verdonschot
Journal:  Injury       Date:  2011-02       Impact factor: 2.586

2.  Clinical experience, primary results and pitfalls in the treatment of intracapsular hip fractures with the Targon® FN locking plate.

Authors:  Rob J P Körver; Arvid W J Wieland; Sjoerd Kaarsemaker; Jeroen J Nieuwenhuis; Heinrich M J Janzing
Journal:  Injury       Date:  2013-06-13       Impact factor: 2.586

3.  Fixation of displaced femoral neck fractures. A comparison between sliding screw plate and four cancellous bone screws.

Authors:  F Madsen; F Linde; E Andersen; H Birke; I Hvass; T D Poulsen
Journal:  Acta Orthop Scand       Date:  1987-06

Review 4.  Internal fixation implants for intracapsular proximal femoral fractures in adults.

Authors:  M J Parker; G Stockton
Journal:  Cochrane Database Syst Rev       Date:  2001

5.  Outcomes after displaced fractures of the femoral neck. A meta-analysis of one hundred and six published reports.

Authors:  G L Lu-Yao; R B Keller; B Littenberg; J E Wennberg
Journal:  J Bone Joint Surg Am       Date:  1994-01       Impact factor: 5.284

6.  Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients.

Authors:  M Parker; S Cawley; V Palial
Journal:  Bone Joint J       Date:  2013-10       Impact factor: 5.082

7.  Internal fixation of intracapsular hip fractures with a dynamic locking plate: initial experience and results for 83 patients treated with a new implant.

Authors:  Martyn J Parker; Hans-Werner Stedtfeld
Journal:  Injury       Date:  2009-10-09       Impact factor: 2.586

Review 8.  Undisplaced intracapsular hip fractures: results of internal fixation in 375 patients.

Authors:  Kevin S Conn; Martyn J Parker
Journal:  Clin Orthop Relat Res       Date:  2004-04       Impact factor: 4.176

  8 in total
  7 in total

Review 1.  Avascular Necrosis of Femoral Head-Overview and Current State of the Art.

Authors:  Wojciech Konarski; Tomasz Poboży; Andrzej Śliwczyński; Ireneusz Kotela; Jan Krakowiak; Martyna Hordowicz; Andrzej Kotela
Journal:  Int J Environ Res Public Health       Date:  2022-06-15       Impact factor: 4.614

2.  [Joint-preserving treatment of medial femoral neck fractures with an angular stable implant].

Authors:  M Saß; T Mittlmeier
Journal:  Oper Orthop Traumatol       Date:  2016-05-03       Impact factor: 1.154

3.  Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study.

Authors:  Yunfeng Tang; Zhen Zhang; Limin Wang; Wei Xiong; Qian Fang; Guanglin Wang
Journal:  J Orthop Surg Res       Date:  2021-08-16       Impact factor: 2.359

4.  The clinical application of a novel method of internal fixation for femoral neck fractures-dynamic locking compression system.

Authors:  Ya-Ping Xiao; Dong-Ping Shu; Ming-Jian Bei; Tao Ji; Wu-Sheng Kan; Shao-Gang Li
Journal:  J Orthop Surg Res       Date:  2018-05-31       Impact factor: 2.359

5.  Clinical Results of Dual SC Screw: A Mini-Sliding Hip Screw with an Anti-rotating Screw for Femoral Neck Fractures.

Authors:  Takafumi Hiranaka; Toshikazu Tanaka; Kenjiro Okumura; Takaaki Fujishiro; Rika Shigemoto; Shotaro Araki; Ryo Okada; Ryohei Nako; Koji Okamoto
Journal:  Clin Orthop Surg       Date:  2021-08-17

Review 6.  The Risk of Avascular Necrosis Following the Stabilization of Femoral Neck Fractures: A Systematic Review and Meta-Analysis.

Authors:  Wojciech Konarski; Tomasz Poboży; Andrzej Kotela; Andrzej Śliwczyński; Ireneusz Kotela; Martyna Hordowicz; Jan Krakowiak
Journal:  Int J Environ Res Public Health       Date:  2022-08-15       Impact factor: 4.614

7.  Dynamic locking plate vs. cannulated cancellous screw for displaced intracapsular hip fracture: A comparative study.

Authors:  Yaniv Warschawski; Tal Frenkel Rutenberg; Shai Factor; Adirian Tudor; Zachary Sharfman; Samuel Morgan; Adi Lichtenstein; Nimrod Snir
Journal:  J Orthop       Date:  2021-02-12
  7 in total