A retrospective study was conducted to investigate the changes in metal ion levels in a consecutive series of Birmingham Hip Resurfacings (BHRs) at a minimum ten-year follow-up. We reviewed 250 BHRs implanted in 232 patients between 1998 and 2001. Implant survival, clinical outcome (Harris hip score), radiographs and serum chromium (Cr) and cobalt (Co) ion levels were assessed. Of 232 patients, 18 were dead (five bilateral BHRs), 15 lost to follow-up and ten had been revised. The remaining 202 BHRs in 190 patients (136 men and 54 women; mean age at surgery 50.5 years (17 to 76)) were evaluated at a minimum follow-up of ten years (mean 10.8 years (10 to 13.6)). The overall implant survival at 13.2 years was 92.4% (95% confidence interval 90.8 to 94.0). The mean Harris hip score was 97.7 (median 100; 65 to 100). Median and mean ion levels were low for unilateral resurfacings (Cr: median 1.3 µg/l, mean 1.95 µg/l (< 0.5 to 16.2); Co: median 1.0 µg/l, mean 1.62 µg/l (< 0.5 to 17.3)) and bilateral resurfacings (Cr: median 3.2 µg/l, mean 3.46 µg/l (< 0.5 to 10.0); Co: median 2.3 µg/l, mean 2.66 µg/l (< 0.5 to 9.5)). In 80 unilateral BHRs with sequential ion measurements, Cr and Co levels were found to decrease significantly (p < 0.001) from the initial assessment at a median of six years (4 to 8) to the last assessment at a median of 11 years (9 to 13), with a mean reduction of 1.24 µg/l for Cr and 0.88 µg/l for Co. Three female patients had a > 2.5 µg/l increase of Co ions, associated with head sizes ≤ 50 mm, clinical symptoms and osteolysis. Overall, there was no significant difference in change of ion levels between genders (Cr, p = 0.845; Co, p = 0.310) or component sizes (Cr, p = 0.505; Co, p = 0.370). Higher acetabular component inclination angles correlated with greater change in ion levels (Cr, p = 0.013; Co, p = 0.002). Patients with increased ion levels had lower Harris hip scores (p = 0.038). In conclusion, in well-functioning BHRs the metal ion levels decreased significantly at ten years. An increase > 2.5 µg/l was associated with poor function.

Entities:  

Keywords:  Hip resurfacing; Metal ions; Metal-on-metal; Survivorship

Mesh:

Substances:

Year:  2013        PMID: 24078528     DOI: 10.1302/0301-620X.95B10.32022

Source DB:  PubMed          Journal:  Bone Joint J        ISSN: 2049-4394            Impact factor:   5.082


  17 in total

1.  Follow-up guidance for metal-on-metal hip replacement patients should be updated.

Authors:  Gulraj S Matharu; Stephen J Mellon; David W Murray; Hemant G Pandit
Journal:  Int Orthop       Date:  2015-01-21       Impact factor: 3.075

2.  Potential presence of metals in patients treated with metal-metal coupling prostheses for hip arthroplasty at 7 and 10 years of follow-up.

Authors:  Giuseppe Sessa; Gianluca Testa; Salvatore Gioitta Iachino; Luciano Costarella; Calogero Puma Pagliarello; Margherita Ferrante; Alfina Grasso; Vito Pavone
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-01-22

Review 3.  The future role of metal-on-metal hip resurfacing.

Authors:  Gulraj S Matharu; Hemant G Pandit; David W Murray; Ronan B C Treacy
Journal:  Int Orthop       Date:  2015-02-24       Impact factor: 3.075

4.  Design Considerations for the Next Generation Hip Resurfacing Implant: Commentary.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2016-12-19

5.  Long-term results of Birmingham hip resurfacing arthroplasty in Asian patients.

Authors:  Keisuke Uemura; Masaki Takao; Hidetoshi Hamada; Takashi Sakai; Kenji Ohzono; Nobuhiko Sugano
Journal:  J Artif Organs       Date:  2017-08-30       Impact factor: 1.731

6.  Current indications for hip resurfacing arthroplasty in 2016.

Authors:  Robert Sershon; Rishi Balkissoon; Craig J Della Valle
Journal:  Curr Rev Musculoskelet Med       Date:  2016-03

7.  How much does a Medical and Healthcare Products Regulatory Agency medical device alert for metal-on-metal hip arthroplasty patients really cost?

Authors:  Rajpal S Nandra; Usman Ahmed; Fiona Berryman; Lesley Brash; David J Dunlop; Gulraj S Matharu
Journal:  Hip Int       Date:  2021-01-14       Impact factor: 1.756

8.  How do metal ion levels change over time in hip resurfacing patients? A cohort study.

Authors:  Lucia Savarino; Matteo Cadossi; Eugenio Chiarello; Caterina Fotia; Michelina Greco; Nicola Baldini; Sandro Giannini
Journal:  ScientificWorldJournal       Date:  2014-12-14

9.  Blood metal ions after hybrid metal-on-polyethylene Exeter-Trident total hip replacement.

Authors:  Rohit Singh; Gopikanthan Manoharan; Pete Craig; Simon Collier; Phillip Shaylor; Ashok Sinha
Journal:  J Orthop Traumatol       Date:  2015-07-24

10.  Metal-on-metal hip resurfacing arthroplasty provides excellent long-term survivorship and function in patients with a good-sized femoral head : results of a single, non-designer surgeon's cohort.

Authors:  M Haseeb Gani; Ubaid Zahoor; Sammy A Hanna; Gareth Scott
Journal:  Bone Jt Open       Date:  2022-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.