OBJECTIVES: To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS: An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS: Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS: Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.
OBJECTIVES: To find the best pairing of first and second reader at highest sensitivity for detecting lung nodules with CT at various dose levels. MATERIALS AND METHODS: An anthropomorphic lung phantom and artificial lung nodules were used to simulate screening CT-examination at standard dose (100 mAs, 120 kVp) and 8 different low dose levels, using 120, 100 and 80 kVp combined with 100, 50 and 25 mAs. At each dose level 40 phantoms were randomly filled with 75 solid and 25 ground glass nodules (5-12 mm). Two radiologists and 3 different computer aided detection softwares (CAD) were paired to find the highest sensitivity. RESULTS: Sensitivities at standard dose were 92%, 90%, 84%, 79% and 73% for reader 1, 2, CAD1, CAD2, CAD3, respectively. Combined sensitivity for human readers 1 and 2 improved to 97%, (p1=0.063, p2=0.016). Highest sensitivities--between 97% and 99.0%--were achieved by combining any radiologist with any CAD at any dose level. Combining any two CADs, sensitivities between 85% and 88% were significantly lower than for radiologists combined with CAD (p<0.03). CONCLUSIONS: Combination of a human observer with any of the tested CAD systems provide optimal sensitivity for lung nodule detection even at reduced dose at 25 mAs/80 kVp.
Authors: Marjolein A Heuvelmans; Matthijs Oudkerk; Pim A de Jong; Willem P Mali; Harry J M Groen; Rozemarijn Vliegenthart Journal: Eur Radiol Date: 2014-11-04 Impact factor: 5.315
Authors: Adrian Huber; Julia Landau; Lukas Ebner; Yanik Bütikofer; Lars Leidolt; Barbara Brela; Michelle May; Johannes Heverhagen; Andreas Christe Journal: Eur Radiol Date: 2016-01-26 Impact factor: 5.315
Authors: Matthijs Oudkerk; ShiYuan Liu; Marjolein A Heuvelmans; Joan E Walter; John K Field Journal: Nat Rev Clin Oncol Date: 2020-10-12 Impact factor: 66.675
Authors: Stefano Young; Pechin Lo; Grace Kim; Matthew Brown; John Hoffman; William Hsu; Wasil Wahi-Anwar; Carlos Flores; Grace Lee; Frederic Noo; Jonathan Goldin; Michael McNitt-Gray Journal: Med Phys Date: 2017-03-14 Impact factor: 4.071
Authors: Alan A Peters; Adrian T Huber; Verena C Obmann; Johannes T Heverhagen; Andreas Christe; Lukas Ebner Journal: Eur Radiol Date: 2022-01-21 Impact factor: 5.315