Literature DB >> 24049695

Real-time optical pH measurement in a standard microfluidic cell culture system.

Einar B Magnusson1, Skarphedinn Halldorsson, Ronan M T Fleming, Kristjan Leosson.   

Abstract

The rapid growth of microfluidic cell culturing in biological and biomedical research and industry calls for fast, non-invasive and reliable methods of evaluating conditions such as pH inside a microfluidic system. We show that by careful calibration it is possible to measure pH within microfluidic chambers with high accuracy and precision, using a direct single-pass measurement of light absorption in a commercially available phenol-red-containing cell culture medium. The measurement is carried out using a standard laboratory microscope and, contrary to previously reported methods, requires no modification of the microfluidic device design. We demonstrate the validity of this method by measuring absorption of light transmitted through 30-micrometer thick microfluidic chambers, using an inverted microscope fitted with a scientific-grade digital camera and two bandpass filters. In the pH range of 7-8, our measurements have a standard deviation and absolute error below 0.05 for a measurement volume smaller than 4 nL.

Entities:  

Keywords:  (120.0120) Instrumentation, measurement, and metrology; (120.3940) Metrology; (120.7000) Transmission; (170.1420) Biology; (300.1030) Absorption

Year:  2013        PMID: 24049695      PMCID: PMC3771845          DOI: 10.1364/BOE.4.001749

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  12 in total

Review 1.  Miniaturized immunoassays: moving beyond the microplate.

Authors:  Thorsten Verch; Ray Bakhtiar
Journal:  Bioanalysis       Date:  2012-01       Impact factor: 2.681

2.  Expanding the available assays: adapting and validating In-Cell Westerns in microfluidic devices for cell-based assays.

Authors:  Amy L Paguirigan; John P Puccinelli; Xiaojing Su; David J Beebe
Journal:  Assay Drug Dev Technol       Date:  2010-07-26       Impact factor: 1.738

Review 3.  Microfluidic cell culture systems for drug research.

Authors:  Min-Hsien Wu; Song-Bin Huang; Gwo-Bin Lee
Journal:  Lab Chip       Date:  2010-01-21       Impact factor: 6.799

Review 4.  Microfluidic devices for bioapplications.

Authors:  Leslie Y Yeo; Hsueh-Chia Chang; Peggy P Y Chan; James R Friend
Journal:  Small       Date:  2011-01-03       Impact factor: 13.281

5.  A high-throughput microfluidic real-time gene expression living cell array.

Authors:  Kevin R King; Sihong Wang; Daniel Irimia; Arul Jayaraman; Mehmet Toner; Martin L Yarmush
Journal:  Lab Chip       Date:  2006-09-29       Impact factor: 6.799

6.  High-throughput analysis of single hematopoietic stem cell proliferation in microfluidic cell culture arrays.

Authors:  Véronique Lecault; Michael Vaninsberghe; Sanja Sekulovic; David J H F Knapp; Stefan Wohrer; William Bowden; Francis Viel; Thomas McLaughlin; Asefeh Jarandehei; Michelle Miller; Didier Falconnet; Adam K White; David G Kent; Michael R Copley; Fariborz Taghipour; Connie J Eaves; R Keith Humphries; James M Piret; Carl L Hansen
Journal:  Nat Methods       Date:  2011-05-22       Impact factor: 28.547

Review 7.  Cells in microfluidics.

Authors:  Chi Zhang; Danny van Noort
Journal:  Top Curr Chem       Date:  2011

8.  Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices.

Authors:  Chen-Fu Lin; Gwo-Bin Lee; Chih-Hao Wang; Huei-Huang Lee; Wei-Yin Liao; Tse-Chuan Chou
Journal:  Biosens Bioelectron       Date:  2005-08-11       Impact factor: 10.618

9.  Beyond PDMS: off-stoichiometry thiol-ene (OSTE) based soft lithography for rapid prototyping of microfluidic devices.

Authors:  Carl Fredrik Carlborg; Tommy Haraldsson; Kim Öberg; Michael Malkoch; Wouter van der Wijngaart
Journal:  Lab Chip       Date:  2011-08-01       Impact factor: 6.799

10.  Single-cell NF-kappaB dynamics reveal digital activation and analogue information processing.

Authors:  Savaş Tay; Jacob J Hughey; Timothy K Lee; Tomasz Lipniacki; Stephen R Quake; Markus W Covert
Journal:  Nature       Date:  2010-06-27       Impact factor: 49.962

View more
  7 in total

1.  A microfluidic optical platform for real-time monitoring of pH and oxygen in microfluidic bioreactors and organ-on-chip devices.

Authors:  Seyed Ali Mousavi Shaegh; Fabio De Ferrari; Yu Shrike Zhang; Mahboubeh Nabavinia; Niema Binth Mohammad; John Ryan; Adel Pourmand; Eleanor Laukaitis; Ramin Banan Sadeghian; Akhtar Nadhman; Su Ryon Shin; Amir Sanati Nezhad; Ali Khademhosseini; Mehmet Remzi Dokmeci
Journal:  Biomicrofluidics       Date:  2016-08-26       Impact factor: 2.800

2.  Defect Density-Dependent pH Response of Graphene Derivatives: Towards the Development of pH-Sensitive Graphene Oxide Devices.

Authors:  Shayan Angizi; Xianxuan Huang; Lea Hong; Md Ali Akbar; P Ravi Selvaganapathy; Peter Kruse
Journal:  Nanomaterials (Basel)       Date:  2022-05-25       Impact factor: 5.719

3.  Genetically Encoded Ratiometric pH Sensors for the Measurement of Intra- and Extracellular pH and Internalization Rates.

Authors:  Lennard Karsten; Lukas Goett-Zink; Julian Schmitz; Raimund Hoffrogge; Alexander Grünberger; Tilman Kottke; Kristian M Müller
Journal:  Biosensors (Basel)       Date:  2022-04-25

4.  PHAIR: a biosensor for pH measurement in air-liquid interface cell culture.

Authors:  Mohammadhossein Dabaghi; Neda Saraei; Gang Xu; Abiram Chandiramohan; Jonas Yeung; Jenny P Nguyen; Milica Vukmirovic; Ponnambalam Ravi Selvaganapathy; Jeremy A Hirota
Journal:  Sci Rep       Date:  2021-02-10       Impact factor: 4.379

Review 5.  Microfluidic Organoids-on-a-Chip: Quantum Leap in Cancer Research.

Authors:  Fahriye Duzagac; Gloria Saorin; Lorenzo Memeo; Vincenzo Canzonieri; Flavio Rizzolio
Journal:  Cancers (Basel)       Date:  2021-02-10       Impact factor: 6.639

6.  A Portable 'Plug-and-Play' Fibre Optic Sensor for In-Situ Measurements of pH Values for Microfluidic Applications.

Authors:  Rahul Kumar; Hien Nguyen; Bruno Rente; Christabel Tan; Tong Sun; Kenneth T V Grattan
Journal:  Micromachines (Basel)       Date:  2022-07-30       Impact factor: 3.523

7.  Monitoring microbial metabolites using an inductively coupled resonance circuit.

Authors:  Daniil Karnaushenko; Larysa Baraban; Dan Ye; Ilke Uguz; Rafael G Mendes; Mark H Rümmeli; J Arjan G M de Visser; Oliver G Schmidt; Gianaurelio Cuniberti; Denys Makarov
Journal:  Sci Rep       Date:  2015-08-12       Impact factor: 4.379

  7 in total