Literature DB >> 16099154

Microfluidic pH-sensing chips integrated with pneumatic fluid-control devices.

Chen-Fu Lin1, Gwo-Bin Lee, Chih-Hao Wang, Huei-Huang Lee, Wei-Yin Liao, Tse-Chuan Chou.   

Abstract

This paper presents a microfluidic chip capable of performing precise continuous pH measurements in an automatic mode. The chip is fabricated using micro-electro-mechanical-systems (MEMS)-based techniques and incorporates polydimethylsiloxane (PDMS) microstructures, pH-sensing electrodes and pneumatic fluid-control devices. Through its enhanced microchannel design and use of pneumatic fluid-control devices, the microfluidic chip reduces the dead volume of the sample and increases the pumping rate. The maximum pumping rate of the developed micro-pump is 28 microL/min at an air pressure of 10 psi and a driving frequency of 10 Hz. The total sample volume consumed in each sensing operation is just 0.515 microL. As a result, the developed chip reduces the sample volume compared to conventional large-scale pH-sensing systems. The microfluidic chip employs the electrochemical sensing method to conduct precise pH level measurements. The sensing electrodes are fabricated by sputtering a layer of SiO(2)-LiO(2)-BaO-TiO(2)-La(2)O(3) (SLBTLO) onto platinum (Pt) electrodes and the pH value of the sample is evaluated by measuring the potential difference between the sensing electrodes and a reference electrode. Additionally, the integration of the microfluidic chip with a pneumatic fluid-control device facilitates automatic sample injection and a continuous sensing operation. The developed system provides a valuable tool with which to examine pH values in a wide range of biomedical and industrial applications.

Entities:  

Mesh:

Year:  2005        PMID: 16099154     DOI: 10.1016/j.bios.2005.06.005

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

1.  Real-time optical pH measurement in a standard microfluidic cell culture system.

Authors:  Einar B Magnusson; Skarphedinn Halldorsson; Ronan M T Fleming; Kristjan Leosson
Journal:  Biomed Opt Express       Date:  2013-08-27       Impact factor: 3.732

2.  Genetically Encoded Ratiometric pH Sensors for the Measurement of Intra- and Extracellular pH and Internalization Rates.

Authors:  Lennard Karsten; Lukas Goett-Zink; Julian Schmitz; Raimund Hoffrogge; Alexander Grünberger; Tilman Kottke; Kristian M Müller
Journal:  Biosensors (Basel)       Date:  2022-04-25

3.  A photoinduced nanoparticle separation in microchannels via pH-sensitive surface traps.

Authors:  Mitsuhiro Ebara; John M Hoffman; Allan S Hoffman; Patrick S Stayton; James J Lai
Journal:  Langmuir       Date:  2013-04-24       Impact factor: 3.882

Review 4.  Recent Progress toward Microfluidic Quality Control Testing of Radiopharmaceuticals.

Authors:  Noel S Ha; Saman Sadeghi; R Michael van Dam
Journal:  Micromachines (Basel)       Date:  2017-11-21       Impact factor: 2.891

Review 5.  Biosensors to Monitor Cell Activity in 3D Hydrogel-Based Tissue Models.

Authors:  Arianna Fedi; Chiara Vitale; Paolo Giannoni; Guido Caluori; Alessandra Marrella
Journal:  Sensors (Basel)       Date:  2022-02-15       Impact factor: 3.576

  5 in total