Literature DB >> 24045545

New fluorescent method (PLT-F) on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting.

Margreet Schoorl1, Marianne Schoorl, Jeanette Oomes, Johannes van Pelt.   

Abstract

OBJECTIVES: In thrombocytopenia, high accuracy and precision of low platelet count is essential for appropriate decisions. The recently introduced Sysmex XN2000 analyzer (Sysmex, Kobe, Japan) offers 3 methods for platelet counting: impedance (PLT-I), optical (PLT-O), and a new fluorescence method (PLT-F). The precision of the PLT-F method in blood samples with platelet counts less than 50 × 10(3)/μL (50 × 10(9)/L) was investigated and compared with the ICSH CD61-ImmunoPLT reference method. For comparison, PLT-I and PLT-O were determined on the Sysmex XN2000 and Sysmex XE2100 analyzer.
METHODS: Blood samples with platelet counts less than 50 × 10(3)/μL (50 × 10(9)/L) (n = 37) were analyzed on the Sysmex XN2000 and XE2100 analyzers. The CD61-ImmunoPLT method was performed on a Beckman Coulter FC-500 flow cytometer (Miami, FL).
RESULTS: At a platelet count of 20 × 10(3)/μL (20 × 10(9)/L), reproducibility for PLT-I, PLT-O, and PLT-F on the XN2000 demonstrated coefficients of variation of 9.3%, 8.5%, and 3.0%, respectively. Correlation between PLT-O on the XN2000 and XE2100 yielded an r value of more than 0.977. Linear regression analysis between the PLT-F and CD61-ImmunoPLT methods resulted in a PLT-F of 0.71*CD61 - 0.8 (r = 0.988). Linear regression between PLT-F and PLT-O on the XN2000 resulted in a PLT-F of 1.05*PLT-O - 2 (r = 0.975), and using the transfusion threshold of 20 × 10(9)/L platelets resulted in a PLT-F of 0.90*PLT-O - 0.4 (r = 0.956).
CONCLUSIONS: The new PLT-F method demonstrated excellent results for reproducibility in samples with platelet counts less than 50 × 10(9)/L. PLT-F could be helpful in making better decisions for platelet transfusions.

Entities:  

Keywords:  PLT-F; PLT-O; Platelet counting; Sysmex XN2000 hematology analyzer; Transfusion platelet threshold

Mesh:

Year:  2013        PMID: 24045545     DOI: 10.1309/AJCPUAGGB4URL5XO

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  12 in total

1.  A Comparison of Mindray BC-6800, Sysmex XN-2000, and Beckman Coulter LH750 Automated Hematology Analyzers: A Pediatric Study.

Authors:  Olga Ciepiela; Iwona Kotuła; Szymon Kierat; Sandra Sieczkowska; Anna Podsiadłowska; Anna Jenczelewska; Karolina Księżarczyk; Urszula Demkow
Journal:  J Clin Lab Anal       Date:  2016-05-17       Impact factor: 2.352

2.  The Sysmex XN-2000 hematology autoanalyzer provides a highly accurate platelet count than the former Sysmex XE-2100 system based on comparison with the CD41/CD61 immunoplatelet reference method of flow cytometry.

Authors:  Sang Hyuk Park; Chan-Jeoung Park; Mi-Jeong Kim; Min-Young Han; Bo-Ra Lee; Young-Uk Cho; Seongsoo Jang
Journal:  Ann Lab Med       Date:  2014-10-28       Impact factor: 3.464

3.  Changes of hematological references depends on storage period and temperature conditions in rats and dogs.

Authors:  Jung-Min Lee; Jin Seok Kang
Journal:  Lab Anim Res       Date:  2016-12-23

4.  Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.

Authors:  Teruko Fukuda; Eri Asou; Kimiko Nogi; Kazuo Goto
Journal:  J Vet Med Sci       Date:  2017-08-27       Impact factor: 1.267

5.  Comments re article on comparison of performance and abnormal cell flagging of two automated hematology analyzers: Sysmex XN 3000 and Beckman Coulter DxH 800.

Authors:  Elena Sukhacheva
Journal:  Int J Lab Hematol       Date:  2019-11-26       Impact factor: 2.877

6.  Compare the accuracy and precision of Coulter LH780, Mindray BC-6000 Plus, and Sysmex XN-9000 with the international reference flow cytometric method in platelet counting.

Authors:  Yi Sun; Zuojian Hu; Zhili Huang; Huaping Chen; Shanzi Qin; Zhong Jianing; Siyuan Chen; Xue Qin; Yi Ye; Chengbin Wang
Journal:  PLoS One       Date:  2019-05-24       Impact factor: 3.240

Review 7.  Pseudothrombocytopenia-A Review on Causes, Occurrence and Clinical Implications.

Authors:  Benjamin Lardinois; Julien Favresse; Bernard Chatelain; Giuseppe Lippi; François Mullier
Journal:  J Clin Med       Date:  2021-02-04       Impact factor: 4.241

8.  Use of Middleware Data to Dissect and Optimize Hematology Autoverification.

Authors:  Rachel D Starks; Anna E Merrill; Scott R Davis; Dena R Voss; Pamela J Goldsmith; Bonnie S Brown; Jeff Kulhavy; Matthew D Krasowski
Journal:  J Pathol Inform       Date:  2021-04-07

9.  Accuracy of a New Platelet Count System (PLT-F) Depends on the Staining Property of Its Reagents.

Authors:  Atsushi Wada; Yuri Takagi; Mari Kono; Takashi Morikawa
Journal:  PLoS One       Date:  2015-10-23       Impact factor: 3.240

Review 10.  Platelet Counting: Ugly Traps and Good Advice. Proposals from the French-Speaking Cellular Hematology Group (GFHC).

Authors:  Véronique Baccini; Franck Geneviève; Hugues Jacqmin; Bernard Chatelain; Sandrine Girard; Soraya Wuilleme; Aurélie Vedrenne; Eric Guiheneuf; Marie Toussaint-Hacquard; Fanny Everaere; Michel Soulard; Jean-François Lesesve; Valérie Bardet
Journal:  J Clin Med       Date:  2020-03-16       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.