Literature DB >> 24043616

MRI of the foetal brain using a rapid 3D steady-state sequence.

P D Griffiths1, D Jarvis, H McQuillan, F Williams, M Paley, P Armitage.   

Abstract

OBJECTIVE: To evaluate the capacity of a rapid T2 weighted three-dimensional (3D) sequence to diagnose foetal brain abnormalities by comparing the results with current two-dimensional (2D) methods. We have also made assessments of the estimates of energy deposition using those methods.
METHODS: 50 pregnant females were included in this study under the guidance of the institutional review board. All their foetuses had suspected brain abnormalities on antenatal ultrasonography or were at increased risk of a brain malformation based on the results of an earlier pregnancy. All the foetuses had a routine MR protocol that includes three orthogonal plane single-shot fast-spin echoes and 2D steady-state sequences. In addition, a 3D rapid steady-state sequence of the foetal brain was performed (acquisition time approximately 40 s), and the standard and 3D sequences were reported independently and the results were compared. The specific absorption rate (SAR) predicted by the scanner was recorded in 12 cases in order to estimate the energy deposited by the three sequences.
RESULTS: The 3D rapid steady-state sequences produced diagnostic-quality images in 41/50 (82%) cases. All the failures were in second trimester foetuses (9/26-35% failure rate). There was a discrepancy between the standard report and findings using the 3D sequence in 2/41 of the foetuses with good-quality 3D imaging. The predicted SAR deposition of the 3D steady-state sequences was comparable with the single-shot fast-spin echo sequence.
CONCLUSION: Our initial assessments of a 3D rapid steady-state sequence to image the foetus are encouraging in terms of diagnostic information and acceptable energy deposition values. The high failure rate in second trimester foetuses probably relates to the greater mobility of the smaller foetuses, and improvements in the 3D sequence are required in terms of reduced acquisition time and higher resolution. ADVANCES IN KNOWLEDGE: We have shown that 3D T2 weighted images of the foetal brain can be acquired in a clinical setting and produce diagnostic-quality imaging in a high proportion of cases. The success rate in acquiring diagnostic-quality images is related to gestational age. Good-quality images were obtained in all third trimester foetuses but only in approximately two-thirds of second trimester foetuses. This probably reflects the problem of the greater mobility of second trimester foetuses. 3D T2 weighted acquisitions have great potential for improving the antenatal diagnosis of foetal brain abnormalities and may reduce the time that a pregnant female needs to spend on the MR scanner.

Entities:  

Mesh:

Year:  2013        PMID: 24043616      PMCID: PMC3798328          DOI: 10.1259/bjr.20130168

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  11 in total

1.  Reconstruction of scattered data in fetal diffusion MRI.

Authors:  Estanislao Oubel; Mériam Koob; Colin Studholme; Jean-Louis Dietemann; François Rousseau
Journal:  Med Image Anal       Date:  2011-04-27       Impact factor: 8.545

Review 2.  Fetal imaging of central nervous system abnormalities.

Authors:  Anna M Golja; Judy A Estroff; Richard L Robertson
Journal:  Neuroimaging Clin N Am       Date:  2004-05       Impact factor: 2.264

3.  Fetal central nervous system anomalies: MR imaging augments sonographic diagnosis.

Authors:  D Levine; P D Barnes; J R Madsen; W Li; R R Edelman
Journal:  Radiology       Date:  1997-09       Impact factor: 11.105

4.  Fast MR imaging of fetal CNS anomalies in utero.

Authors:  E M Simon; R B Goldstein; F V Coakley; R A Filly; K C Broderick; T J Musci; A J Barkovich
Journal:  AJNR Am J Neuroradiol       Date:  2000-10       Impact factor: 3.825

5.  [Cerebral fetal MRI and ventriculomegaly].

Authors:  S Launay; Y Robert; A S Valat; D Thomas; L Devisme; N Rocourt; P Vaast
Journal:  J Radiol       Date:  2002-06

6.  Comparison of ultrasound and magnetic resonance imaging in 100 singleton pregnancies with suspected brain abnormalities.

Authors:  E H Whitby; M N J Paley; A Sprigg; S Rutter; N P Davies; I D Wilkinson; P D Griffiths
Journal:  BJOG       Date:  2004-08       Impact factor: 6.531

7.  Two-dimensional fast imaging employing steady-state acquisition (FIESTA) cine acquisition of fetal non-central nervous system abnormalities.

Authors:  Shu-Huei Shen; Wan-Yuo Guo; Jeng-Hsiu Hung
Journal:  J Magn Reson Imaging       Date:  2007-09       Impact factor: 4.813

8.  Real-time fetal magnetic resonance imaging for the dynamic visualization of the pouch in esophageal atresia.

Authors:  L J Salomon; P Sonigo; P Ou; Y Ville; F Brunelle
Journal:  Ultrasound Obstet Gynecol       Date:  2009-10       Impact factor: 7.299

9.  Intersection based motion correction of multislice MRI for 3-D in utero fetal brain image formation.

Authors:  Kio Kim; Piotr A Habas; Francois Rousseau; Orit A Glenn; Anthony J Barkovich; Colin Studholme
Journal:  IEEE Trans Med Imaging       Date:  2009-09-09       Impact factor: 10.048

10.  A prospective study of fetuses with isolated ventriculomegaly investigated by antenatal sonography and in utero MR imaging.

Authors:  P D Griffiths; M J Reeves; J E Morris; G Mason; S A Russell; M N J Paley; E H Whitby
Journal:  AJNR Am J Neuroradiol       Date:  2009-09-17       Impact factor: 4.966

View more
  5 in total

Review 1.  Quantitative magnetic resonance imaging of the fetal brain in utero: Methods and applications.

Authors:  Anat Biegon; Chen Hoffmann
Journal:  World J Radiol       Date:  2014-08-28

2.  In Utero MR Imaging of Fetal Holoprosencephaly: A Structured Approach to Diagnosis and Classification.

Authors:  P D Griffiths; D Jarvis
Journal:  AJNR Am J Neuroradiol       Date:  2015-11-12       Impact factor: 3.825

3.  Gestational age and neonatal brain microstructure in term born infants: a birth cohort study.

Authors:  Birit F P Broekman; Changqing Wang; Yue Li; Anne Rifkin-Graboi; Seang Mei Saw; Yap-Seng Chong; Kenneth Kwek; Peter D Gluckman; Marielle V Fortier; Michael J Meaney; Anqi Qiu
Journal:  PLoS One       Date:  2014-12-23       Impact factor: 3.240

4.  Schizencephaly revisited.

Authors:  Paul D Griffiths
Journal:  Neuroradiology       Date:  2018-07-19       Impact factor: 2.804

5.  An integrated in utero MR method for assessing structural brain abnormalities and measuring intracranial volumes in fetuses with congenital heart disease: results of a prospective case-control feasibility study.

Authors:  Paul D Griffiths; Hatem A Mousa; Chloe Finney; Cara Mooney; Laura Mandefield; Timothy J A Chico; Deborah Jarvis
Journal:  Neuroradiology       Date:  2019-02-22       Impact factor: 2.804

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.