Literature DB >> 24030583

Development of metal/metal hip resurfacing.

D J W McMinn1.   

Abstract

This author's development of metal/metal hip resurfacing began in 1989, with the first patient implantation in February 1991. In the first three years a pilot study identified optimum fixation as hydroxyapatite coated uncemented cups and cemented femoral components. From March 1994 hybrid fixed components have been used. These implants have generally been satisfactory with respect to fixation but high wear of the bearing, metallosis and osteolysis have been seen with some components inserted during 1996, a period during which the metal microstructure was altered by the heat processes, hot isostatic pressing and solution heat treatment. The Birmingham Hip Resurfacing was developed taking account of experience with earlier resurfacing designs. This implant employs hybrid fixation with a porous ingrowth acetabular component and has an as-cast metal microstructure having had no post casting heat treatments. During the past 4 years the author has performed over 1,000 Birmingham Hip Resurfacingís with a total failure rate of less than 1.0%.

Entities:  

Year:  2003        PMID: 24030583     DOI: 10.1177/112070000301302s09

Source DB:  PubMed          Journal:  Hip Int        ISSN: 1120-7000            Impact factor:   1.756


  9 in total

1.  [Hip resurfacing arthroplasty].

Authors:  W-C Witzleb; A Knecht; T Beichler; T Köhler; K-P Günther
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

2.  [Durom™ hip resurfacing. Short- to midterm clinical and radiological outcome].

Authors:  J Goronzy; M Stiehler; S Kirschner; K-P Günther
Journal:  Orthopade       Date:  2010-09       Impact factor: 1.087

Review 3.  [Resurfacing arthroplasty of the hip].

Authors:  A Knecht; W-C Witzleb; K-P Günther
Journal:  Orthopade       Date:  2005-01       Impact factor: 1.087

Review 4.  [Blood flow to the femoral head and hip resurfacing arthroplasty].

Authors:  P E Beaulé; R Ganz; M Leunig
Journal:  Orthopade       Date:  2008-07       Impact factor: 1.087

5.  What should I expect from my recalled Adept Hip Resurfacing?

Authors:  Matteo Cadossi; Silvio Terrando; Andrea Sambri; Giuseppe Tedesco; Antonio Mazzotti; Barbara Bordini; Dalila De Pasquale; Cesare Faldini
Journal:  Musculoskelet Surg       Date:  2017-04-27

6.  [Surgical principles and clinical experiences with the DUROM hip resurfacing system using a lateral approach].

Authors:  Sascha Gravius; Torsten Mumme; Oliver Weber; Philipp Berdel; Dieter Christian Wirtz
Journal:  Oper Orthop Traumatol       Date:  2009-12       Impact factor: 1.154

Review 7.  [Uncemented arthroplasty of the hip].

Authors:  C von Schulze Pellengahr; A Fottner; S Utzschneider; M Schmitt-Sody; W Teske; T Lichtinger; S A Esenwein
Journal:  Orthopade       Date:  2009-05       Impact factor: 1.087

8.  Resurfacing total hip replacement--a therapeutical approach in postmenopausal women with osteoporosis and hip arthrosis.

Authors:  D Popescu; R Ene; C Cirstoiu
Journal:  J Med Life       Date:  2011-05-25

9.  The correlation between activity level, serum-ion concentrations and pseudotumours in patients with metal-on-metal hip articulations and metal-on-polyethylene total hip articulations.

Authors:  Mette Holm Hjorth; Inger Mechlenburg; Kjeld Soballe; Lone Roemer; Maiken Stilling
Journal:  J Orthop Translat       Date:  2018-12-17       Impact factor: 5.191

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.