Literature DB >> 2401413

Effect of luminance and contrast on stereoscopic acuity.

T Geib1, C Baumann.   

Abstract

The threshold of binocular depth perception was measured in 11 healthy volunteers. A three-rod arrangement was employed in which both the luminance of the rods and that of the adapting field could be adjusted independently. This allowed fixing the contrast when the effect of luminance was studied or fixing the luminance when the effect of contrast was investigated. The observation distance was 400 mm. Thresholds were expressed as angular disparities and were based on 75% correct responses. Points of subjective equality were also determined. Lowest thresholds (2.85 +/- 0.67 s of arc) were found for a moderate contrast of 0.5 whereas low (0.05) and high (0.95) contrast both produced significantly higher thresholds (luminance 250 cd/m2). Altering the field luminance (50, 250, 1600 cd/m2) under constant contrast conditions (0.95) did not measurably influence stereoscopic acuity.

Mesh:

Year:  1990        PMID: 2401413     DOI: 10.1007/bf00920053

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  10 in total

1.  Variation of stereoscopic acuity with observation distance.

Authors:  G AMIGO
Journal:  J Opt Soc Am       Date:  1963-05

2.  Stereoscopic vision and the duration of the stimulus.

Authors:  K N OGLE; M P WEIL
Journal:  AMA Arch Ophthalmol       Date:  1958-01

3.  Stereoscopic Acuity for Various Levels of Illumination.

Authors:  C G Mueller; V V Lloyd
Journal:  Proc Natl Acad Sci U S A       Date:  1948-05       Impact factor: 11.205

4.  THE METHOD OF PROBITS.

Authors:  C I Bliss
Journal:  Science       Date:  1934-01-12       Impact factor: 47.728

5.  Size-detecting mechanisms in human vision.

Authors:  A Pantle; R Sekuler
Journal:  Science       Date:  1968-12-06       Impact factor: 47.728

6.  On the existence of neurones in the human visual system selectively sensitive to the orientation and size of retinal images.

Authors:  C Blakemore; F W Campbell
Journal:  J Physiol       Date:  1969-07       Impact factor: 5.182

7.  Blurred visual stimuli. II. The effect of blurred visual stimuli on vernier and stereo acuity.

Authors:  G Stigmar
Journal:  Acta Ophthalmol (Copenh)       Date:  1971

8.  Limit of single vision in stereopsis depends on contour sharpness.

Authors:  J J Kulikowski
Journal:  Nature       Date:  1978-09-14       Impact factor: 49.962

9.  Cooperative neural processes involved in stereoscopic acuity.

Authors:  G Westheimer
Journal:  Exp Brain Res       Date:  1979-08-01       Impact factor: 1.972

10.  Spatiotemporal modulation transfer in the human eye.

Authors:  F L van Nes; J J Koenderink; H Nas; M A Bouman
Journal:  J Opt Soc Am       Date:  1967-09
  10 in total
  3 in total

1.  Pitfalls in the Use of Stereoacuity in the Diagnosis of Nonorganic Visual Loss.

Authors:  Kevin R Sitko; Jason H Peragallo; Samuel Bidot; Valerie Biousse; Nancy J Newman; Beau B Bruce
Journal:  Ophthalmology       Date:  2015-10-16       Impact factor: 12.079

2.  A novel clinical dynamic stereopsis assessment based on autostereoscopic display system.

Authors:  Yiyao Wang; Jing Zhong; Mengyi Cheng; Jijing Li; Ke Ma; Xiaoqing Hu; Naiyang Li; Haowen Liang; Zhengyuan Zhu; Jianying Zhou; Jin Yuan
Journal:  Ann Transl Med       Date:  2022-06

3.  Impact on stereo-acuity of two presbyopia correction approaches: monovision and small aperture inlay.

Authors:  Enrique J Fernández; Christina Schwarz; Pedro M Prieto; Silvestre Manzanera; Pablo Artal
Journal:  Biomed Opt Express       Date:  2013-05-08       Impact factor: 3.732

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.