Literature DB >> 24000996

Stopping Criteria for Log-Domain Diffeomorphic Demons Registration: An Experimental Survey for Radiotherapy Application.

M Peroni1, P Golland2, G C Sharp3, G Baroni4.   

Abstract

A crucial issue in deformable image registration is achieving a robust registration algorithm at a reasonable computational cost. Given the iterative nature of the optimization procedure an algorithm must automatically detect convergence, and stop the iterative process when most appropriate. This paper ranks the performances of three stopping criteria and six stopping value computation strategies for a Log-Domain Demons Deformable registration method simulating both a coarse and a fine registration. The analyzed stopping criteria are: (a) velocity field update magnitude, (b) mean squared error, and (c) harmonic energy. Each stoping condition is formulated so that the user defines a threshold ∊, which quantifies the residual error that is acceptable for the particular problem and calculation strategy. In this work, we did not aim at assigning a value to e, but to give insights in how to evaluate and to set the threshold on a given exit strategy in a very popular registration scheme. Experiments on phantom and patient data demonstrate that comparing the optimization metric minimum over the most recent three iterations with the minimum over the fourth to sixth most recent iterations can be an appropriate algorithm stopping strategy. The harmonic energy was found to provide best trade-off between robustness and speed of convergence for the analyzed registration method at coarse registration, but was outperformed by mean squared error when all the original pixel information is used. This suggests the need of developing mathematically sound new convergence criteria in which both image and vector field information could be used to detect the actual convergence, which could be especially useful when considering multi-resolution registrations. Further work should be also dedicated to study same strategies performances in other deformable registration methods and body districts.
© The Author(s) 2014.

Entities:  

Keywords:  Deformable registration; Demons; Optimization; Stopping criteria.

Mesh:

Year:  2014        PMID: 24000996      PMCID: PMC5027647          DOI: 10.7785/tcrtexpress.2013.600269

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  16 in total

1.  Evaluation of multiple-atlas-based strategies for segmentation of the thyroid gland in head and neck CT images for IMRT.

Authors:  A Chen; K J Niermann; M A Deeley; B M Dawant
Journal:  Phys Med Biol       Date:  2011-11-29       Impact factor: 3.609

2.  Ranking of stopping criteria for log domain diffeomorphic demons application in clinical radiation therapy.

Authors:  M Peroni; P Golland; G C Sharp; G Baroni
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

3.  Contributions to 3D diffeomorphic atlas estimation: application to brain images.

Authors:  Matias Bossa; Monica Hernandez; Salvador Olmos
Journal:  Med Image Comput Comput Assist Interv       Date:  2007

Review 4.  A review of geometric transformations for nonrigid body registration.

Authors:  M Holden
Journal:  IEEE Trans Med Imaging       Date:  2008-01       Impact factor: 10.048

5.  Diffeomorphic demons: efficient non-parametric image registration.

Authors:  Tom Vercauteren; Xavier Pennec; Aymeric Perchant; Nicholas Ayache
Journal:  Neuroimage       Date:  2008-11-07       Impact factor: 6.556

6.  Image matching as a diffusion process: an analogy with Maxwell's demons.

Authors:  J P Thirion
Journal:  Med Image Anal       Date:  1998-09       Impact factor: 8.545

7.  Evaluation of registration methods on thoracic CT: the EMPIRE10 challenge.

Authors:  Keelin Murphy; Bram van Ginneken; Joseph M Reinhardt; Sven Kabus; Kai Ding; Xiang Deng; Kunlin Cao; Kaifang Du; Gary E Christensen; Vincent Garcia; Tom Vercauteren; Nicholas Ayache; Olivier Commowick; Grégoire Malandain; Ben Glocker; Nikos Paragios; Nassir Navab; Vladlena Gorbunova; Jon Sporring; Marleen de Bruijne; Xiao Han; Mattias P Heinrich; Julia A Schnabel; Mark Jenkinson; Cristian Lorenz; Marc Modat; Jamie R McClelland; Sébastien Ourselin; Sascha E A Muenzing; Max A Viergever; Dante De Nigris; D Louis Collins; Tal Arbel; Marta Peroni; Rui Li; Gregory C Sharp; Alexander Schmidt-Richberg; Jan Ehrhardt; René Werner; Dirk Smeets; Dirk Loeckx; Gang Song; Nicholas Tustison; Brian Avants; James C Gee; Marius Staring; Stefan Klein; Berend C Stoel; Martin Urschler; Manuel Werlberger; Jef Vandemeulebroucke; Simon Rit; David Sarrut; Josien P W Pluim
Journal:  IEEE Trans Med Imaging       Date:  2011-05-31       Impact factor: 10.048

8.  A fast inverse consistent deformable image registration method based on symmetric optical flow computation.

Authors:  Deshan Yang; Hua Li; Daniel A Low; Joseph O Deasy; Issam El Naqa
Journal:  Phys Med Biol       Date:  2008-10-14       Impact factor: 3.609

9.  Demons deformable registration for CBCT-guided procedures in the head and neck: convergence and accuracy.

Authors:  S Nithiananthan; K K Brock; M J Daly; H Chan; J C Irish; J H Siewerdsen
Journal:  Med Phys       Date:  2009-10       Impact factor: 4.071

Review 10.  Imaging in radiation oncology: a perspective.

Authors:  Laura A Dawson; Cynthia Ménard
Journal:  Oncologist       Date:  2010
View more
  1 in total

1.  Multimodal image registration for liver radioembolization planning and patient assessment.

Authors:  Nadine Spahr; Smita Thoduka; Nasreddin Abolmaali; Ron Kikinis; Andrea Schenk
Journal:  Int J Comput Assist Radiol Surg       Date:  2018-10-22       Impact factor: 2.924

  1 in total