Literature DB >> 23992999

A clinical evaluation of the ProNOVA XR polymer-free sirolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions (EURONOVA XR I study).

Jacek Legutko1, Wojciech Zasada, Grzegorz L Kałuża, Grzegorz Heba, Lukasz Rzeszutko, Jacek Jakala, Jacek Dragan, Artur Klecha, Dawid Giszterowicz, Wojciech Dobrowolski, Lukasz Partyka, Swaminathan Jayaraman, Dariusz Dudek.   

Abstract

AIMS: Evaluation of safety and efficacy of ProNOVA XR, a new generation of polymer-free sirolimus eluting stents (SES), utilizing a pharmaceutical excipient for timed release of sirolimus from the XR platform. METHODS AND
RESULTS: Safety and efficacy of ProNOVA XR coronary stent system was examined in EURONOVA prospective, single arm, multi-center registry of 50 patients with de novo native coronary lesions up to 28 mm in length in arteries between 2.25 and 4 mm. At 6-month, in-stent late lumen loss by QCA was 0.45 ± 0.41 mm and in-stent neointimal volume obstruction in the IVUS sub-study was 14 ± 11%. One-year clinical follow-up revealed a favorable safety profile, with 2% of in-hospital MACE and 6.4% of MACE from hospital discharge up to 12 months (including 1 cardiac death >30 days after stent implantation and 2 TLRs). According to the ARC definition, there was no definite or probable stent thrombosis and 1 possible stent thrombosis (2%) up to 12 months of clinical follow-up.
CONCLUSIONS: In this preliminary evaluation, ProNOVA XR polymer-free sirolimus eluting stent system appeared safe with an early promise of adequate effectiveness in the treatment of de novo coronary lesions in up to 12 months of clinical, angiographic and IVUS follow-up.
Copyright © 2013 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  DES; EEM; IVUS; PF; QCA; external elastic membrane; polymer-free

Mesh:

Substances:

Year:  2013        PMID: 23992999      PMCID: PMC3860607          DOI: 10.1016/j.ihj.2013.06.026

Source DB:  PubMed          Journal:  Indian Heart J        ISSN: 0019-4832


  20 in total

Review 1.  American College of Cardiology Clinical Expert Consensus Document on Standards for Acquisition, Measurement and Reporting of Intravascular Ultrasound Studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents.

Authors:  G S Mintz; S E Nissen; W D Anderson; S R Bailey; R Erbel; P J Fitzgerald; F J Pinto; K Rosenfield; R J Siegel; E M Tuzcu; P G Yock
Journal:  J Am Coll Cardiol       Date:  2001-04       Impact factor: 24.094

Review 2.  Very late thrombosis after drug-eluting stents.

Authors:  Fausto Feres; J Ribamar Costa; Alexandre Abizaid
Journal:  Catheter Cardiovasc Interv       Date:  2006-07       Impact factor: 2.692

3.  Late and very late drug-eluting stent malapposition: serial 2-year quantitative IVUS analysis.

Authors:  Soo-Jin Kang; Gary S Mintz; Duk-Woo Park; Seung-Whan Lee; Young-Hak Kim; Cheol Whan Lee; Ki-Hoon Han; Jae-Joong Kim; Seong-Wook Park; Seung-Jung Park
Journal:  Circ Cardiovasc Interv       Date:  2010-07-06       Impact factor: 6.546

4.  The outcome of bifurcation lesion stenting using a biolimus-eluting stent with a bio-degradable polymer compared to a sirolimus-eluting stent with a durable polymer.

Authors:  Scot Garg; Joanna Wykrzykowska; Patrick W Serruys; Ton de Vries; Pawel Buszman; Stanislaw Trznadel; Axel Linke; Karsten Lenk; Thomas Ischinger; Volker Klauss; Franz Eberli; Roberto Corti; William Wijns; Marie-Claude Morice; Carlo di Mario; Pawel Tyczynski; Robert Jan van Geuns; Pedro Eerdmans; Gerrit-Anne van Es; Bernhard Meier; Peter Jüni; Stephan Windecker
Journal:  EuroIntervention       Date:  2011-03       Impact factor: 6.534

5.  Safety and efficacy of sirolimus- and paclitaxel-eluting coronary stents.

Authors:  Gregg W Stone; Jeffrey W Moses; Stephen G Ellis; Joachim Schofer; Keith D Dawkins; Marie-Claude Morice; Antonio Colombo; Erick Schampaert; Eberhard Grube; Ajay J Kirtane; Donald E Cutlip; Martin Fahy; Stuart J Pocock; Roxana Mehran; Martin B Leon
Journal:  N Engl J Med       Date:  2007-02-12       Impact factor: 91.245

6.  Analysis of 1-year clinical outcomes in the SIRIUS trial: a randomized trial of a sirolimus-eluting stent versus a standard stent in patients at high risk for coronary restenosis.

Authors:  David R Holmes; Martin B Leon; Jeffrey W Moses; Jeffrey J Popma; Donald Cutlip; Peter J Fitzgerald; Charles Brown; Tim Fischell; Shing Chiu Wong; Mark Midei; David Snead; Richard E Kuntz
Journal:  Circulation       Date:  2004-02-10       Impact factor: 29.690

7.  Randomised comparison of Nobori, biolimus A9-eluting coronary stent with a Taxus(R), paclitaxel-eluting coronary stent in patients with stenosis in native coronary arteries: the Nobori 1 trial.

Authors:  Bernard Chevalier; Patrick W Serruys; Sigmund Silber; Eulogio Garcia; Harry Suryapranata; Karl Hauptmann; William Wijns; Gerhard Schuler; Farzin Fath-Ordoubadi; Stephen Worthley; Leif Thuesen; Ian Meredith; Marco Bressers; Hirofumi Nagai; Dragica Paunovic
Journal:  EuroIntervention       Date:  2007-02       Impact factor: 6.534

8.  A polymer-free dual drug-eluting stent in patients with coronary artery disease: a randomized trial vs. polymer-based drug-eluting stents.

Authors:  Robert A Byrne; Julinda Mehilli; Raisuke Iijima; Stefanie Schulz; Jürgen Pache; Melchior Seyfarth; Albert Schömig; Adnan Kastrati
Journal:  Eur Heart J       Date:  2009-02-24       Impact factor: 29.983

Review 9.  Outcomes associated with drug-eluting and bare-metal stents: a collaborative network meta-analysis.

Authors:  Christoph Stettler; Simon Wandel; Sabin Allemann; Adnan Kastrati; Marie Claude Morice; Albert Schömig; Matthias E Pfisterer; Gregg W Stone; Martin B Leon; José Suarez de Lezo; Jean-Jacques Goy; Seung-Jung Park; Manel Sabaté; Maarten J Suttorp; Henning Kelbaek; Christian Spaulding; Maurizio Menichelli; Paul Vermeersch; Maurits T Dirksen; Pavel Cervinka; Anna Sonia Petronio; Alain J Nordmann; Peter Diem; Bernhard Meier; Marcel Zwahlen; Stephan Reichenbach; Sven Trelle; Stephan Windecker; Peter Jüni
Journal:  Lancet       Date:  2007-09-15       Impact factor: 79.321

10.  1-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single de novo coronary lesions: the VESTASYNC I trial.

Authors:  J Ribamar Costa; Alexandre Abizaid; Ricardo Costa; Fausto Feres; Luiz Fernando Tanajura; Andréa Abizaid; Galo Maldonado; Rodolfo Staico; Dimytri Siqueira; Amanda G M R Sousa; Raoul Bonan; J Eduardo Sousa
Journal:  JACC Cardiovasc Interv       Date:  2009-05       Impact factor: 11.195

View more
  3 in total

Review 1.  Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

Authors:  Shuji Otsuki; Manel Sabaté
Journal:  World J Cardiol       Date:  2014-09-26

Review 2.  Non-polymer drug-eluting coronary stents.

Authors:  Nagavendra Kommineni; Raju Saka; Wahid Khan; Abraham J Domb
Journal:  Drug Deliv Transl Res       Date:  2018-08       Impact factor: 4.617

3.  Longitudinal Stent Deformation at Aneurysm Site: Flexibility at the Expense of Longitudinal Integrity.

Authors:  Bhupesh R Shah
Journal:  J Clin Diagn Res       Date:  2017-07-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.