Literature DB >> 19463465

1-year results of the hydroxyapatite polymer-free sirolimus-eluting stent for the treatment of single de novo coronary lesions: the VESTASYNC I trial.

J Ribamar Costa1, Alexandre Abizaid, Ricardo Costa, Fausto Feres, Luiz Fernando Tanajura, Andréa Abizaid, Galo Maldonado, Rodolfo Staico, Dimytri Siqueira, Amanda G M R Sousa, Raoul Bonan, J Eduardo Sousa.   

Abstract

OBJECTIVES: We sought to assess the safety and efficacy of the novel VESTAsync-eluting stent (MIV Therapeutics, Atlanta, Georgia) combining a stainless steel platform with a nanothin-microporous hydroxyapatite surface coating impregnated with a polymer-free low-dose of sirolimus (55 microg).
BACKGROUND: Durable polymers in first-generation drug-eluting stents (DES) have been linked to local inflammatory reaction leading to a positive vessel remodeling, late incomplete stent apposition, and in some cases, stent thrombosis. The removal of the polymer from the DES system could increase the safety profile of this novel technology.
METHODS: A total of 15 patients with single de novo lesions in native coronary arteries with 3.0- to 3.5-mm diameter and <or=14-mm length were enrolled in this first-in-man study. Primary end point was in-stent late lumen loss (LL) at 4 and 9 months.
RESULTS: Baseline characteristics included mean age of 63 years and 33% of diabetics. Reference vessel diameter and lesion length were 2.7 +/- 0.3 mm and 10 +/- 2.0 mm, respectively. Procedure success was obtained in all cases. Lifelong aspirin and 5-month clopidogrel treatment were prescribed to all patients. At 4 months, in-stent LL and percentage of neointimal hyperplasia were 0.3 +/- 0.25 mm and 2.6 +/- 2.2%, respectively, with a nonsignificant increase at 9 months (0.36 +/- 0.23 mm and 4.0 +/- 2.2%, respectively). Serial intravascular ultrasound did not show late incomplete stent apposition. There were no major adverse cardiac events within 1 year of follow-up.
CONCLUSIONS: The novel VESTAsync-eluting stent was effective in reducing LL and neointimal hyperplasia at 4 and 9 months, with no evidence of late catch-up by quantitative coronary angiography or intravascular ultrasound.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19463465     DOI: 10.1016/j.jcin.2009.02.009

Source DB:  PubMed          Journal:  JACC Cardiovasc Interv        ISSN: 1936-8798            Impact factor:   11.195


  24 in total

1.  Low-dose sirolimus-eluting hydroxyapatite coating on stents does not increase platelet activation and adhesion ex vivo.

Authors:  Carlos L Alviar; Armando Tellez; Michael Wang; Pamela Potts; Doug Smith; Manus Tsui; Wladyslaw Budzynski; Albert E Raizner; Neal S Kleiman; Eli I Lev; Juan F Granada; Greg L Kaluza
Journal:  J Thromb Thrombolysis       Date:  2012-07       Impact factor: 2.300

2.  A clinical evaluation of the ProNOVA XR polymer-free sirolimus eluting coronary stent system in the treatment of patients with de novo coronary artery lesions (EURONOVA XR I study).

Authors:  Jacek Legutko; Wojciech Zasada; Grzegorz L Kałuża; Grzegorz Heba; Lukasz Rzeszutko; Jacek Jakala; Jacek Dragan; Artur Klecha; Dawid Giszterowicz; Wojciech Dobrowolski; Lukasz Partyka; Swaminathan Jayaraman; Dariusz Dudek
Journal:  Indian Heart J       Date:  2013-07-21

Review 3.  Nanotechnology in diagnosis and treatment of coronary artery disease.

Authors:  Mahdi Karimi; Hossein Zare; Amirala Bakhshian Nik; Narges Yazdani; Mohammad Hamrang; Elmira Mohamed; Parham Sahandi Zangabad; Seyed Masoud Moosavi Basri; Leila Bakhtiari; Michael R Hamblin
Journal:  Nanomedicine (Lond)       Date:  2016-02-23       Impact factor: 5.307

Review 4.  New drug-eluting stent concepts.

Authors:  Rainer Wessely
Journal:  Nat Rev Cardiol       Date:  2010-03-02       Impact factor: 32.419

5.  A new polymer-free drug-eluting stent with nanocarriers eluting sirolimus from stent-plus-balloon compared with bare-metal stent and with biolimus A9 eluting stent in porcine coronary arteries.

Authors:  Celso K Takimura; Micheli Z Galon; Paulo S Gutierrez; Prakash Sojitra; Ashwin Vyas; Manish Doshi; Pedro A Lemos
Journal:  Cardiovasc Diagn Ther       Date:  2015-04

Review 6.  Drug-eluting stents and acute myocardial infarction: A lethal combination or friends?

Authors:  Shuji Otsuki; Manel Sabaté
Journal:  World J Cardiol       Date:  2014-09-26

Review 7.  Microfabrication and nanotechnology in stent design.

Authors:  Adam W Martinez; Elliot L Chaikof
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2011-01-31

Review 8.  New-Generation Coronary Stents: Current Data and Future Directions.

Authors:  Ankur Kalra; Hasan Rehman; Sahil Khera; Braghadheeswar Thyagarajan; Deepak L Bhatt; Neal S Kleiman; Robert W Yeh
Journal:  Curr Atheroscler Rep       Date:  2017-03       Impact factor: 5.113

9.  [New developments in drug-eluting stents].

Authors:  M Kollum; C Bode
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 10.  Drug-eluting stents in percutaneous coronary intervention: a benefit-risk assessment.

Authors:  Robert A Byrne; Nikolaus Sarafoff; Adnan Kastrati; Albert Schömig
Journal:  Drug Saf       Date:  2009       Impact factor: 5.606

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.