Literature DB >> 23991281

Traditional elastic ligatures versus slide ligation system. A morphological evaluation.

R Condò1, A Casaglia, E Armellin, S G Condò, L Cerroni.   

Abstract

OBJECTIVE: Elastomeric materials play an important role in the orthodontic practice, including the retraction force to move teeth into extraction sites, closing diastemas, selective shifting of the midline and generalized space closure. Frictional resistance and ligating strength of archwire-bracket-ligature complex occurs during utilization of elastomeric and metallic ligatures when orthodontic forces are applicated. The aim of this study was to analyze elastic deformation of three types of elastomeric ligatures, after clinical use.
MATERIAL AND METHODS: ELASTOMERIC LIGATURES: ring-shape, transparent, latex ligatures (Leone® S.p.A.), ring-shape, grey, polyurethane ligatures (Micerium® S.p.A.) and grey, polyurethane, Slide low-friction ligatures (Leone® S.p.A.). A total of 9 orthodontic patients undergoing fixed orthodontic therapy were selected. Three specimens were applied, one for each types of ligature, inside the oral cavity of each subject. Samples were kept in the oral cavity for 28 days, ligating 0.16 X 0.22 inches stainless steel archwires to stainless steel premolars brackets (Leone® S.p.A., Sesto Fiorentino, FI, Italy) for Bidimensional technique. After the pre-established time, the systems of ligature were removed and washed. Control group consisted of 9 unused specimens of each ligation type. Each elastomeric ligature was observed under the scanning electron microscope (SEM) to determine variations in size. The archwire-bracket-ligature complex was also analyzed.
RESULTS: Transparent O-ring ligatures showed significant volumetric and structural changes. The external rounded shape was rather maintained, while the internal shape tended to appear square. Both external and internal diameter significantly increased (p<0.005 and p<0.0001 respectively) while the thickness decreased ( p<0,005) when analyzed with t-test. Polyurethane ring-shape ligatures retained the initial ring design. Both external and internal diameter increased (p<0.0001), while the thickness remained almost unchanged. The internal border was more squared, and showed jagged edges with continuous and irregular extroversions. Grey, polyurethane Slide low-friction ligatures showed a reduced dimensional change. There was a slight increase in two dimensions, length and width, (14-16%) (p<0.05 and p<0.001) while there was a not significant decrease in thickness (10%).
CONCLUSION: From SEM analysis of ligature morphology it emerges that latex and polyurethane O-ring ligatures endure significant volumetric and structural changes, after clinical use, index of a greater degree of friction and early loss in functionality. Grey, polyurethane Slide low-friction ligatures presented limited variation in size after clinical use.

Entities:  

Keywords:  SEM; deformation; orthodontic ligature

Year:  2013        PMID: 23991281      PMCID: PMC3755808     

Source DB:  PubMed          Journal:  Oral Implantol (Rome)        ISSN: 1974-5648


  24 in total

1.  Structural conformation of in vitro and in vivo aged orthodontic elastomeric modules.

Authors:  T Eliades; G Eliades; D C Watts
Journal:  Eur J Orthod       Date:  1999-12       Impact factor: 3.075

2.  The effect of ligation method on friction in sliding mechanics.

Authors:  Max Hain; Ashish Dhopatkar; Peter Rock
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-04       Impact factor: 2.650

3.  Tensile properties of orthodontic elastomeric chains.

Authors:  T Eliades; G Eliades; N Silikas; D C Watts
Journal:  Eur J Orthod       Date:  2004-04       Impact factor: 3.075

4.  Tensile properties of orthodontic elastomeric ligatures.

Authors:  F Ahrari; T Jalaly; M Zebarjad
Journal:  Indian J Dent Res       Date:  2010 Jan-Mar

5.  Effects of prestretching on force degradation of synthetic elastomeric chains.

Authors:  Kyung-Ho Kim; Chun-Hsi Chung; Kwnagchul Choy; Jeong-Sub Lee; Robert L Vanarsdall
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-10       Impact factor: 2.650

6.  In vitro frictional forces generated by three different ligation methods.

Authors:  Paola Gandini; Linda Orsi; Chiara Bertoncini; Sarah Massironi; Lorenzo Franchi
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

7.  [Elastomeric materials].

Authors:  Aurélie Pic
Journal:  Orthod Fr       Date:  2009-03-28

8.  Frictional resistance between orthodontic brackets and archwires in the buccal segments.

Authors:  N G Taylor; K Ison
Journal:  Angle Orthod       Date:  1996       Impact factor: 2.079

9.  Debris, roughness and friction of stainless steel archwires following clinical use.

Authors:  Isabella Silva Vieira Marques; Adriana M Araújo; Júlio A Gurgel; David Normando
Journal:  Angle Orthod       Date:  2010-05       Impact factor: 2.079

10.  Physical properties of conventional and Super Slick elastomeric ligatures after intraoral use.

Authors:  Nicola Louise Crawford; Caroline McCarthy; Tanya C Murphy; Philip Edward Benson
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

View more
  4 in total

1.  Friction behavior of self-ligating and conventional brackets with different ligature systems.

Authors:  Alexandra Szczupakowski; Susanne Reimann; Cornelius Dirk; Ludger Keilig; Anna Weber; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-05-24       Impact factor: 1.938

2.  Contamination of Low Frictional Elastomeric Ligatures by Streptococcus mutans: A Prospective RT-PCR and AFM Study.

Authors:  Caglar Dagdeviren; Aysegul Gulec; Fahriye Eksi; Mustafa Saglam; Mehmet Kahraman
Journal:  Turk J Orthod       Date:  2021-09

3.  Metals and Metalloids Release from Orthodontic Elastomeric and Stainless Steel Ligatures: In Vitro Risk Assessment of Human Exposure.

Authors:  Aneta Olszewska; Anetta Hanć; Danuta Barałkiewicz; Piotr Rzymski
Journal:  Biol Trace Elem Res       Date:  2019-11-04       Impact factor: 3.738

4.  Comparison of frictional resistance between passive self-ligating brackets and slide-type low-friction ligature brackets during the alignment and leveling stage.

Authors:  Sandra-Liliana Gómez-Gómez; Junes-Abdul Villarraga-Ossa; Juan-Gustavo Diosa-Peña; Juan-Fernando Ortiz-Restrepo; Robinson-Andrés Castrillón-Marín; Carlos M Ardila
Journal:  J Clin Exp Dent       Date:  2019-07-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.