Literature DB >> 12695769

The effect of ligation method on friction in sliding mechanics.

Max Hain1, Ashish Dhopatkar, Peter Rock.   

Abstract

During orthodontic tooth movement with the preadjusted edgewise system, friction generated at the bracket/archwire interface tends to impede the desired movement. The method of ligation is an important contributor to this frictional force. This in vitro study investigated the effect of ligation method on friction and evaluated the efficacy of the new slick elastomeric modules from TP Orthodontics (La Porte, Ind), which are claimed to reduce friction at the module/wire interface. Slick modules were compared with regular nonslick modules, stainless steel ligatures, and the SPEED self-ligating bracket system (Strite Industries, Cambridge, Ontario, Canada). The effect of using slick modules with metal-reinforced ceramic (Clarity, 3M Unitek, Monrovia, Calif) and miniature brackets (Minitwin, 3M Unitek) was also examined. Results showed that, when considering tooth movement along a 0.019 x 0.025-in stainless steel archwire, saliva-lubricated slick modules can reduce static friction at the module/archwire interface by up to 60%, regardless of the bracket system. The SPEED brackets produced the lowest friction compared with the 3 other tested bracket systems when regular modules were used. The use of slick modules, however, with all of the ligated bracket types tested significantly reduced friction to below the values recorded in the SPEED groups. Loosely tied stainless steel ligatures were found to generate the least friction.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12695769     DOI: 10.1067/mod.2003.14

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  42 in total

1.  Comparative evaluation of anchorage loss between self-ligating appliance and Conventional pre-adjusted edgewise appliance using sliding mechanics - A retrospective study.

Authors:  Pankaj Juneja; G Shivaprakash; S S Chopra; P B Kambalyal
Journal:  Med J Armed Forces India       Date:  2014-04-03

2.  Traditional elastic ligatures versus slide ligation system. A morphological evaluation.

Authors:  R Condò; A Casaglia; E Armellin; S G Condò; L Cerroni
Journal:  Oral Implantol (Rome)       Date:  2013-07-15

3.  Tooth movement rate and anchorage lost during canine retraction: A maxillary and mandibular comparison.

Authors:  Andre da C Monini; Luiz G Gandini; Alexandre P Vianna; Renato P Martins; Helder B Jacob
Journal:  Angle Orthod       Date:  2019-02-11       Impact factor: 2.079

4.  Friction in a hybrid system. An in vitro study.

Authors:  M Rozzi; M Mucedero; L Franchi; P Cozza
Journal:  Oral Implantol (Rome)       Date:  2011-01-23

5.  A comparison of lower canine retraction and loss of anchorage between conventional and self-ligating brackets: a single-center randomized split-mouth controlled trial.

Authors:  André da Costa Monini; Luiz Gonzaga Gandini Júnior; Alexandre Protásio Vianna; Renato Parsekian Martins
Journal:  Clin Oral Investig       Date:  2016-05-31       Impact factor: 3.573

6.  Evaluation of friction in orthodontics using various brackets and archwire combinations-an in vitro study.

Authors:  Sujeet Kumar; Shamsher Singh; Rani Hamsa P R; Sameer Ahmed; Apoorva Bhatnagar; Manreet Sidhu; Pramod Shetty
Journal:  J Clin Diagn Res       Date:  2014-05-15

7.  Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

Authors:  Vanessa Vieira Leite; Murilo Baena Lopes; Alcides Gonini Júnior; Marcio Rodrigues de Almeida; Sandra Kiss Moura; Renato Rodrigues de Almeida
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

8.  A comparative study to evaluate the effects of ligation methods on friction in sliding mechanics using 0.022" slot brackets in dry state: An In-vitro study.

Authors:  K Vinay; M J Venkatesh; Rabindra S Nayak; Azam Pasha; M Rajesh; Pradeep Kumar
Journal:  J Int Oral Health       Date:  2014-04-26

9.  Friction between Archwire of Different Sizes, Cross Section, Alloy and Brackets Ligated with Different Brands of Low Friction Elastic Ligatures- An Invitro Study.

Authors:  Bhushan Patil; Neeraj Suresh Patil; Veerendra Virupaxappa Kerudi; Shrikant Shrinivas Chitko; Amit Ratanlal Maheshwari; Harshal Ashok Patil; Nikhita Popatrao Pekhale; Pawankumar Dnyandeo Tekale
Journal:  J Clin Diagn Res       Date:  2016-04-01

10.  The Effects of In-Office Reconditioning on the Slot Dimensions and Static Frictional Resistance of Stainless Steel Brackets.

Authors:  Rohini Iluru; Chaitanya Nellore; Praveen Kumar Reddy Karnati; Ashok Kumar Thalapaneni; Vijay Bhaskar Myla; Konda Ramyasree; Mandava Prasad
Journal:  J Clin Diagn Res       Date:  2016-01-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.