Literature DB >> 23974630

Bench test assessment of mainstream capnography during high frequency oscillatory ventilation.

Caroline M Hartdorff1, Marc van Heerde, Dick G Markhorst.   

Abstract

To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into an artificial lung and the output of the CO2 sensor assessed under varying ventilator settings. Influence of oxygen content, pressures, heat and moisture were recorded. A linear relationship between CO2 flow rate and PETCO2 was found. Varying ventilator settings influenced the measurements, but the results for PETCO2 remained within a range of 1.5 mmHg above or under then mean measurement value. Measurements remained stable despite humidification, heat, pressure amplitudes or mean airway pressure changes. From this bench test, we conclude it is feasible to measure PETCO2 using a main stream capnograph during high frequency oscillatory conditions, these measurements were stable during the experiment. Changes in CO2 production or output can be detected. The system may prove to be of clinical value, but further in vivo measurements are warranted.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23974630     DOI: 10.1007/s10877-013-9495-9

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  10 in total

1.  Attenuation of pressure swings along the endotracheal tube is indicative of optimal distending pressure during high-frequency oscillatory ventilation in a model of acute lung injury.

Authors:  Huibert R van Genderingen; Adrianus J van Vught; Elisabeth L I M Duval; Dick G Markhorst; Jos R C Jansen
Journal:  Pediatr Pulmonol       Date:  2002-06

2.  Breath-to-breath analysis of abdominal and rib cage motion in surfactant-depleted piglets during high-frequency oscillatory ventilation.

Authors:  Dick G Markhorst; Jos R C Jansen; Adrianus J van Vught; Huibert R van Genderingen
Journal:  Intensive Care Med       Date:  2005-01-20       Impact factor: 17.440

Review 3.  High-frequency oscillatory ventilation: mechanisms of gas exchange and lung mechanics.

Authors:  J Jane Pillow
Journal:  Crit Care Med       Date:  2005-03       Impact factor: 7.598

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

Review 5.  Monitoring of standard hemodynamic parameters: heart rate, systemic blood pressure, atrial pressure, pulse oximetry, and end-tidal CO2.

Authors:  V Ben Sivarajan; Desmond Bohn
Journal:  Pediatr Crit Care Med       Date:  2011-07       Impact factor: 3.624

6.  Capnometry during high-frequency oscillatory ventilation.

Authors:  M Nishimura; H Imanaka; C Tashiro; N Taenaka; I Yoshiya
Journal:  Chest       Date:  1992-06       Impact factor: 9.410

7.  Continuous integrated distal capnography in infants ventilated with high frequency ventilation.

Authors:  Amir Kugelman; Arieh Riskin; Irit Shoris; Michal Ronen; Iris Shalev Stein; David Bader
Journal:  Pediatr Pulmonol       Date:  2012-02-10

8.  High-frequency oscillatory ventilation for acute respiratory distress syndrome in adults: a randomized, controlled trial.

Authors:  Stephen Derdak; Sangeeta Mehta; Thomas E Stewart; Terry Smith; Mark Rogers; Timothy G Buchman; Brian Carlin; Stuart Lowson; John Granton
Journal:  Am J Respir Crit Care Med       Date:  2002-09-15       Impact factor: 21.405

9.  Prospective, randomized comparison of high-frequency oscillatory ventilation and conventional mechanical ventilation in pediatric respiratory failure.

Authors:  J H Arnold; J H Hanson; L O Toro-Figuero; J Gutiérrez; R J Berens; D L Anglin
Journal:  Crit Care Med       Date:  1994-10       Impact factor: 7.598

10.  Simple and accurate assessment of energy expenditure in ventilated paediatric intensive care patients.

Authors:  Martijn van der Kuip; Kees de Meer; Michiel J S Oosterveld; Harry N Lafeber; Reinoud J B J Gemke
Journal:  Clin Nutr       Date:  2004-08       Impact factor: 7.324

  10 in total
  1 in total

Review 1.  Journal of clinical monitoring and computing 2014 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-03-04       Impact factor: 2.502