| Literature DB >> 23967130 |
Xijiao Liu1, Li Zou, Fei Liu, Yin Zhou, Bin Song.
Abstract
OBJECTIVE: To determine the accuracy of MR imaging with gadoxetic acid disodium (Gd-EOB-DTPA) for the detection of hepatocelluar carcinoma (HCC).Entities:
Mesh:
Substances:
Year: 2013 PMID: 23967130 PMCID: PMC3744536 DOI: 10.1371/journal.pone.0070896
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Figure 1Flowchart illustrating the selection of studies.
Characteristics of the included 10 studies.
| No | Study | Year | Nation | TP | FP | FN | TN | No. of Tumors | Study Design | Magnetic field strength | Dose of Gd-EOB-DTPA | Patients | ||
| Enrollment | Ratio of Men to Women | Child-Pugh classification (A/B/C) | ||||||||||||
| 1 | Bashir | 2013 | American | 64 | 14 | 6 | 41 | 125 | retro | 1.5/3.0T | 10ml | consecutive cirrhosis patients,22mo (9/08–6/10) | 57/43 | ND |
| 2 | Blondin | 2011 | Germany | 37 | 1 | 4 | 5 | 47 | retro | 1.5T | 10ml | consecutive patients,26mo (1/07–3/09) | 25/8 | 22/9/2 |
| 3 | Filippone | 2010 | Italy | 36 | 1 | 3 | 14 | 54 | retro | 1.5T | 0.025mmol/Kg | cirrhosis patients,31mo (9/07–4/10) | 27/7 | 21/8/5 |
| 4 | Ooka | 2012 | Japan | 82 | 10 | 5 | 344 | 441 | retro | 1.5T | 0.025mmol/Kg | consecutive patients,16mo (2/08–6/09) | 40/14 | 46/8/0 |
| 5 | Baek | 2010 | Korea | 63 | 4 | 10 | 55 | 132 | retro | 3.0T | 0.025mmol/Kg | consecutive patients,13mo(5/08–6/09) | 43/8 | 42/7/2 |
| 6 | Akai | 2011 | Japan | 46 | 2 | 6 | 52 | 106 | pro | 1.5T | 0.025mmol/Kg | consecutive patients,8mo (6/08–2/09) | 27/7 | ND |
| 7 | Park | 2012 | Korea | 147 | 2 | 32 | 142 | 323 | retro | 3.0T | 0.025mmol/Kg | consecutive cirrhosis patients,13mo (5/09–6/10) | 185/75 | 230/28/2 |
| 8 | Sano | 2011 | Japan | 88 | 6 | 3 | 155 | 252 | retro | 1.5T | 0.025mmol/Kg | consecutive patients,22mo (1/08–11/09) | 47/17 | 54/10/0 |
| 9 | Golfieri | 2011 | Italy | 172 | 2 | 1 | 40 | 215 | pro | 1.5T | 0.025mmol/Kg | consecutive cirrhosis patients,13mo (5/08–10/09) | 127/0 | ND |
| 10 | Haradome | 2011 | Japan | 52 | 3 | 8 | 36 | 99 | retro | 1.5T | 0.025mmol/Kg | consecutive patients,17mo (1/08–6/09) | 60/15 | 48/5/22 |
TP, true-positive; FP, false-positive; TN, true-negative; FN, false-negative; ND, no data.
Figure 2Methodological quality of the 10 included studies.
Figure 3Forest plots of the estimates for MR imaging with Gd-EOB-DTPA for the detection of HCC.
Figure 4Summary receiver operating characteristic (SROC) curves of MR imaging with Gd-EOB-DTPA in detection of HCC.
Figure 5The funnel plot of publication bias: Linear regression of the inverse root of effective sample sizes (ESS) on a log DOR is performed.