Body MRI artifacts in clinical practice: a physicist's and radiologist's perspective.

Martin J Graves1, Donald G Mitchell.   

Abstract

The high information content of MRI exams brings with it unintended effects, which we call artifacts. The purpose of this review is to promote understanding of these artifacts, so they can be prevented or properly interpreted to optimize diagnostic effectiveness. We begin by addressing static magnetic field uniformity, which is essential for many techniques, such as fat saturation. Eddy currents, resulting from imperfect gradient pulses, are especially problematic for new techniques that depend on high performance gradient switching. Nonuniformity of the transmit radiofrequency system constitutes another source of artifacts, which are increasingly important as magnetic field strength increases. Defects in the receive portion of the radiofrequency system have become a more complex source of problems as the number of radiofrequency coils, and the sophistication of the analysis of their received signals, has increased. Unwanted signals and noise spikes have many causes, often manifesting as zipper or banding artifacts. These image alterations become particularly severe and complex when they are combined with aliasing effects. Aliasing is one of several phenomena addressed in our final section, on artifacts that derive from encoding the MR signals to produce images, also including those related to parallel imaging, chemical shift, motion, and image subtraction.
Copyright © 2013 Wiley Periodicals, Inc.

Keywords:  MRI; artifacts; body imaging; image quality

Mesh:

Substances:

Year:  2013        PMID: 23960007     DOI: 10.1002/jmri.24288

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  12 in total

1.  A 12-step user guide for analyzing voxel-wise gray matter asymmetries in statistical parametric mapping (SPM).

Authors:  Florian Kurth; Christian Gaser; Eileen Luders
Journal:  Nat Protoc       Date:  2015-01-15       Impact factor: 13.491

Review 2.  Body MR Imaging: Artifacts, k-Space, and Solutions.

Authors:  Susie Y Huang; Ravi T Seethamraju; Pritesh Patel; Peter F Hahn; John E Kirsch; Alexander R Guimaraes
Journal:  Radiographics       Date:  2015-07-24       Impact factor: 5.333

Review 3.  Image-quality optimization and artifact reduction in fetal magnetic resonance imaging.

Authors:  Fedel Machado-Rivas; Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2020-11-30

4.  Distortion-free inside-out imaging for rapid diagnostics of rechargeable Li-ion cells.

Authors:  Konstantin Romanenko; Alexej Jerschow
Journal:  Proc Natl Acad Sci U S A       Date:  2019-08-30       Impact factor: 11.205

5.  A Brief Survey on No-Reference Image Quality Assessment Methods for Magnetic Resonance Images.

Authors:  Igor Stępień; Mariusz Oszust
Journal:  J Imaging       Date:  2022-06-04

6.  Magnetic resonance imaging artifacts produced by dental implants with different geometries.

Authors:  Lauren Bohner; Norbert Meier; Felix Gremse; Pedro Tortamano; Johannes Kleinheinz; Marcel Hanisch
Journal:  Dentomaxillofac Radiol       Date:  2020-07-02       Impact factor: 2.419

Review 7.  Artifacts in magnetic resonance imaging.

Authors:  Katarzyna Krupa; Monika Bekiesińska-Figatowska
Journal:  Pol J Radiol       Date:  2015-02-23

8.  Cardiac magnetic resonance imaging: artefacts for clinicians.

Authors:  A W M van der Graaf; P Bhagirath; S Ghoerbien; M J W Götte
Journal:  Neth Heart J       Date:  2014-12       Impact factor: 2.380

9.  MRI safety risks in the obese: The case of the disposable lighter stored in the pannus.

Authors:  H Michael Gach; Stacie L Mackey; Sarah E Hausman; Danielle R Jackson; Tammie L Benzinger; Lauren Henke; Lindsay A Murphy; Jamie L Fluchel; Bin Cai; Jacqueline E Zoberi; Jose Garcia-Ramirez; Sasa Mutic; Julie K Schwarz
Journal:  Radiol Case Rep       Date:  2019-03-15

10.  Magnetic Resonance Imaging of Postoperative Fracture Healing Process without Metal Artifact: A Preliminary Report of a Novel Animal Model.

Authors:  Zhe Jin; Yuheng Guan; Guibo Yu; Yu Sun
Journal:  Biomed Res Int       Date:  2016-03-31       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.