Literature DB >> 23949790

Effects of step duration in incremental ramp protocols on peak power and maximal oxygen consumption.

Alessandra Adami1, Andrea Sivieri, Christian Moia, Renza Perini, Guido Ferretti.   

Abstract

PURPOSE: Morton (J Sport Sci 29:307-309, 2011) proposed a model of the peak power attained in ramp protocol ([Formula: see text]) that included critical power (CP) and anaerobic capacity as constants, and mean ramp slope (S) as variable. Our hypothesis is that [Formula: see text] depends only on S, so that Morton's model should be applicable in all types of ramps. The aim of this study was to test this hypothesis by validating Morton's model using stepwise ramp tests with invariant step increment and increasing step duration.
METHODS: Sixteen men performed six ramp tests with 25 W increments. Step duration was: 15, 30, 60, 90, 120 and 180 s. Maximal oxygen consumption ([Formula: see text]) and [Formula: see text] were identified as the highest values reached during each test. An Åstrand-type test was also performed. We measured oxygen consumption and ventilatory variables, together with lactate and heart rate.
RESULTS: [Formula: see text] was the same in all tests; [Formula: see text] was significantly lower the longer the step duration, and all values differed from the maximal power of the Åstrand-type test ([Formula: see text]). Morton's model yielded an excellent fitting, with mean CP equal to 198.08 ± 37.46 W and anaerobic capacity equal to 16.82 ± 5.69 kJ.
CONCLUSIONS: Morton's model is a good descriptor of the mechanics of ramp tests. Further developments of Morton's model demonstrated that, whereas [Formula: see text] is a protocol-dependent variable, the difference between [Formula: see text] and CP is a constant, so that their values do not depend on the protocol applied.

Entities:  

Mesh:

Year:  2013        PMID: 23949790     DOI: 10.1007/s00421-013-2705-9

Source DB:  PubMed          Journal:  Eur J Appl Physiol        ISSN: 1439-6319            Impact factor:   3.078


  24 in total

1.  [Effect of 4 weeks of training on the limit time at VO2 max].

Authors:  Richard Heubert; Valéry Bocquet; Jean Pierre Koralsztein; Véronique Billat
Journal:  Can J Appl Physiol       Date:  2003-10

2.  Influence of testing protocol on ventilatory thresholds and cycling performance.

Authors:  Markus Amann; Andrew Subudhi; Carl Foster
Journal:  Med Sci Sports Exerc       Date:  2004-04       Impact factor: 5.411

3.  Energetics of running in top-level marathon runners from Kenya.

Authors:  Enrico Tam; Huber Rossi; Christian Moia; Claudio Berardelli; Gabriele Rosa; Carlo Capelli; Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2012-03-02       Impact factor: 3.078

4.  Why peak power is higher at the end of steeper ramps: an explanation based on the "critical power" concept.

Authors:  R Hugh Morton
Journal:  J Sports Sci       Date:  2011-02       Impact factor: 3.337

5.  The relationship among peak power output, lactate threshold, and short-distance cycling performance: effects of incremental exercise test design.

Authors:  Lars R McNaughton; Simon Roberts; David J Bentley
Journal:  J Strength Cond Res       Date:  2006-02       Impact factor: 3.775

6.  The effect of stage duration on the calculation of peak VO2 during cycle ergometry.

Authors:  D Bishop; D G Jenkins; L T Mackinnon
Journal:  J Sci Med Sport       Date:  1998-09       Impact factor: 4.319

7.  Comparison of a continuous and discontinuous graded treadmill test for maximal oxygen uptake.

Authors:  M G Maksud; K D Coutts
Journal:  Med Sci Sports       Date:  1971

Review 8.  The bioenergetic and gas exchange basis of exercise testing.

Authors:  B J Whipp
Journal:  Clin Chest Med       Date:  1994-06       Impact factor: 2.878

Review 9.  The energy cost of human locomotion on land and in water.

Authors:  P E di Prampero
Journal:  Int J Sports Med       Date:  1986-04       Impact factor: 3.118

10.  A comparison of incremental exercise tests during cycle and treadmill ergometry.

Authors:  R D Fairshter; J Walters; K Salness; M Fox; V D Minh; A F Wilson
Journal:  Med Sci Sports Exerc       Date:  1983       Impact factor: 5.411

View more
  20 in total

Review 1.  Training-Induced Changes in Mitochondrial Content and Respiratory Function in Human Skeletal Muscle.

Authors:  Cesare Granata; Nicholas A Jamnick; David J Bishop
Journal:  Sports Med       Date:  2018-08       Impact factor: 11.136

Review 2.  Maximal oxygen consumption in healthy humans: theories and facts.

Authors:  Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2014-07-02       Impact factor: 3.078

3.  Influence of acute passive stretching on the oxygen uptake vs work rate slope during an incremental cycle test.

Authors:  Eloisa Limonta; Susanna Rampichini; Andrea Riboli; Massimo Venturelli; Emiliano Cè; Fabio Esposito
Journal:  Eur J Appl Physiol       Date:  2015-10-03       Impact factor: 3.078

4.  Physiological responses to incremental, interval, and continuous counterweighted single-leg and double-leg cycling at the same relative intensities.

Authors:  Martin J MacInnis; Nathaniel Morris; Michael W Sonne; Amanda Farias Zuniga; Peter J Keir; Jim R Potvin; Martin J Gibala
Journal:  Eur J Appl Physiol       Date:  2017-05-11       Impact factor: 3.078

5.  Experimental validation of the 3-parameter critical power model in cycling.

Authors:  Giovanni Vinetti; Anna Taboni; Paolo Bruseghini; Stefano Camelio; Matteo D'Elia; Nazzareno Fagoni; Christian Moia; Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2019-01-29       Impact factor: 3.078

Review 6.  Principles of Exercise Prescription, and How They Influence Exercise-Induced Changes of Transcription Factors and Other Regulators of Mitochondrial Biogenesis.

Authors:  Cesare Granata; Nicholas A Jamnick; David J Bishop
Journal:  Sports Med       Date:  2018-07       Impact factor: 11.136

7.  Effects of recovery interval duration on the parameters of the critical power model for incremental exercise.

Authors:  Giovanni Vinetti; Nazzareno Fagoni; Anna Taboni; Stefano Camelio; Pietro Enrico di Prampero; Guido Ferretti
Journal:  Eur J Appl Physiol       Date:  2017-07-07       Impact factor: 3.078

8.  Factors Influencing AMPK Activation During Cycling Exercise: A Pooled Analysis and Meta-Regression.

Authors:  Jeffrey A Rothschild; Hashim Islam; David J Bishop; Andrew E Kilding; Tom Stewart; Daniel J Plews
Journal:  Sports Med       Date:  2021-12-08       Impact factor: 11.928

9.  Gas analyzer's drift leads to systematic error in maximal oxygen uptake and maximal respiratory exchange ratio determination.

Authors:  Ibai Garcia-Tabar; Jean P Eclache; José F Aramendi; Esteban M Gorostiaga
Journal:  Front Physiol       Date:  2015-10-30       Impact factor: 4.566

10.  An integrated approach in a case of facioscapulohumeral dystrophy.

Authors:  Stefano Pasotti; Bruno Magnani; Emanuela Longa; Giuseppe Giovanetti; Albino Rossi; Angela Berardinelli; Rossella Tupler; Giuseppe D'Antona
Journal:  BMC Musculoskelet Disord       Date:  2014-05-15       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.