PURPOSE: The purpose of the study was clinical and advanced biomechanical evaluation of shoulder function with respect to rotator cuff (RC) integrity following repair.
METHODS: This was a retrospective study of 111 cases with solid single row rotator cuff repair and a minimal one-year follow-up. The RC repair was performed as an open procedure in 42 patients, arthroscopically assisted in 34 and fully arthroscopic in 48 cases. Evaluation protocol included ultrasound evaluation of the RC integrity, clinical evaluation using shoulder scores and advanced biomechanical evaluation (isometric and the isokinetic strength testing).
RESULTS: Ultrasound evaluation revealed complete retear in 16%, partial retear in 10% and intact repair in 74% of the cases. Isometric testing of flexion and abduction had shown that shoulders with complete retear were weaker by 45% compared to those with full tendon healing. Isokinetic testing revealed 29-43% deficits in peak external rotation torque comparing complete retear vs. normal healing. Patients' ability to generate shoulder power and withstand a load proved to be lower in circumstances of a complete lack of healing (40-43% and 34-55%, respectively). Partial retears did not have a negative impact on the biomechanical properties of shoulders. Surprisingly, there were no significant differences in the shoulder scores related to the quality of healing. In terms of patient satisfaction the results were good and the patients declared themselves better in all cases, no matter what quality of healing had been recorded ultimately.
CONCLUSIONS: According to the results of this research rotator cuff integrity after open or arthroscopic repair does not seem to affect clinical scores. Recurrent tears may result in lower muscle performance in terms of active motion, strength and endurance. Advanced shoulder testing may be essential in assessing the patients' ability to return to sports or heavy labour.

Entities:  

Mesh:

Year:  2013        PMID: 23948981      PMCID: PMC3843211          DOI: 10.1007/s00264-013-2024-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


Introduction

Modern rotator cuff (RC) repair includes minimally invasive arthroscopic procedures providing a stable and solid fixation of the tendons to bone and improved biology with the use of growth factors or scaffolds [1-5]. Despite such efforts the number of retears reported in literature is quite significant. Nevertheless, many patients do quite well even in the presence of lost integrity following RC repair [6, 7]. Most commonly the final results are evaluated according to pain level, clinical status and quality of life. However, to have a more thorough understanding of biomechanical capabilities of the shoulder following the rotator cuff repair, we decided to include advanced strength testing. The aim of the study was clinical and advanced biomechanical evaluation of shoulder function with respect to rotator cuff integrity following repair.

Material and methods

The study included 111 patients who had a single-row cuff repair for a total of 124 shoulder repairs. The patients were a part of a cohort including 243 cases operated upon between 2002 and 2009. The research was approved by the ethical committee of our institution and included patients with rotator cuff repair and no other shoulder pathologies with available documentation at the one-year follow-up. All the participating cases gave written consent. The follow-up was performed at an average time of 39.5 months (12–98). The average age of patients was 56 years (40–80), with 84 males and 40 females. The rotator cuff repair was performed as an open procedure in 42 patients, arthroscopically assisted in 34 and fully arthroscopic in 48 cases. Protocol evaluation included ultrasound scans, clinical evaluation and advanced strength testing. The ultrasound evaluation of rotator cuff integrity had been performed by a ten-year experienced musculoskeletal radiologist, using the 5–12 MHz linear transducer (HD11 XE system, Phillips Ultrasound, Andover, MA, USA). The insertion and the repair sites were graded as complete retear (cRT), partial retear (pRT) and no retear (nRT). Complete retear was assigned if full thickness tear was diagnosed throughout the width of the repaired RC. Partial retear was rated to partially preserved continuity of the repaired cuff. Fully preserved continuity, with full coverage of footprint by cuff tendons, was regarded as no retear (nRT) (Fig. 1).
Fig. 1

Longitudinal ultrasound scans showing complete retear of supraspinatus tendon (a), partial healing (partial retear) (b) and preserved integrity at the repair site (c)

Longitudinal ultrasound scans showing complete retear of supraspinatus tendon (a), partial healing (partial retear) (b) and preserved integrity at the repair site (c) Clinical evaluation included assessment of the active ranges of motion (ROM), pain level (0–10 VAS) and clinical scores: UCLA (University of California in Los-Angeles), the simple shoulder test (SST), and the American Shoulder and Elbow Surgeons (ASES) index (SSI). Advanced biomechanical evaluation was based on shoulder strength testing performed in isometric and isokinetic mode. The isometric evaluation of shoulder flexion, abduction, internal and external rotation was performed using electronic dynamometer with dedicated PC software (Forcemeter, Progress, Poland). The patient was always examined in a standing position (Fig. 2). The device was attached either to the floor (flexion, abduction) or the wall (internal and external rotation). The belt was adjusted accordingly and held at the patients’ wrist. Flexion strength was evaluated with the arm in a 90° frontal deviation, with abduction at a 90° deviation in the scapular plane. Internal and external rotation strength was examined with the arm along the side and elbow flexed to 90°. Maximum value [N] was recorded in a six second period of maximum contracture.
Fig. 2

Isometric testing for abduction (a), flexion (b) and external rotation (c); device (d) and interface (e)

Isometric testing for abduction (a), flexion (b) and external rotation (c); device (d) and interface (e) Isokinetic shoulder evaluation was performed by means of the Biodex System 3 (Biodex Medical Systems, Inc., Shirley, NY) (Fig. 3) for external and internal rotation; values taken into consideration included peak torque, peak torque to body weight, average power and total work. Measurements were performed at 90, 180, 270 and 360°/s. Isokinetic testing was performed according to the standard protocol used in our institutions. The patient was seated and stabilised in the chair in standard sitting position. Rotation movements were performed successively in four angular velocities 180°/s, 90°/s, 360°/s and 270°/s. Peak torque represents the actual strength of the motion. Peak torque related to body weight is considered to more accurately compare the results between patients with different body sizes. Total work accounts for the ability to maintain peak torque over a period of time and practically describes the resistance to fatigue. Average power represents the dynamics of movement and the ability to generate torque within a short time [8].
Fig. 3

Isokinetic shoulder testing: setup (a, b); data collection (c)

Isokinetic shoulder testing: setup (a, b); data collection (c) Statistical analysis was performed using StatPlus mac 2009 software (AnalystSoft) and included normality tests and the analysis of variance (ANOVA).

Results

The ultrasound evaluation revealed complete retear in 20 cases (16 %), partial retear in 12 cases (10 %) and no retear in 92 (74 %) cases (Fig. 1). The average age in the three groups was 55 years (40–71) in the nRT, 53 years (43–74) in the pRT and 57 years in the retear group (46–80) with a majority of males, respectively, of 64 %, 81 % and 65 %. The results of the clinical evaluation, isometric and isokinetic testing are displayed in Tables 1, 2, and 3. The level of pain and the follow-up time were significantly higher for the partial retears when compared with the group with intact cuffs. The integrity of the repaired tendons did not make any difference in the clinical scores. Patients with complete retears had significantly lower active flexion, showing no other significant differences in the measured range of active motion.
Table 1

Result of clinical evaluation

Clinical assessmentAverages ± SDStatistical significance by ANOVA (p values)
Complete retear (cRT)Partial retear (pRT)No retear (nRT)cRT vs. nRTcRT vs. pRTpRT vs. nRT
Pain (VAS)3 ± 3.43.7 ± 2.32.1 ± 2.4nsns0.049
SSI-ASES73 ± 26.570.2 ± 13.879.7 ± 21.3nsnsns
SST8.9 ± 3.69.8 ± 2.39.6 ± 3.2nsnsns
UCLA27.2 ± 7.629.6 ± 4.529.4 ± 5.9nsnsns
Flexion (°)145 ± 32169.1 ± 20.2163.6 ± 32.90.0310.05ns
Abduction (°)150.3 ± 32.5171.8 ± 15.4159.6 ± 36.6nsnsns
External rotation (°)47.1 ± 22.855 ± 20.954 ± 21.8nsnsns

ns not significant with p > 0.05

UCLA University of California in Los Angeles, SST simple shoulder test, SSI-ASES American Shoulder and Elbow Surgeons index

Table 2

Results of isometric shoulder testing by Forcemeter

Isometric strengthMeans ± SDStatistical significance by ANOVA (p values)
Complete retear (cRT)Partial retear (pRT)No retear (nRT)cRT vs. nRTcRT vs. pRTpRT vs. nRT
Flexion31. ± 2259.1 ± 21.258.5 ± 37.20.0050.047ns
Abduction33 ± 19.652.8 ± 27.256.9 ± 350.042nsns
External rotation53.5 ± 31.665.3 ± 19.273.9 ± 39.80.05nsns
Internal rotation65.2 ± 29.680.4 ± 15.989.3 ± 43.20.040nsns

ns not significant with p > 0.05

Table 3

Results of isokinetic shoulder testing by Biodex System 3

Isokinetic testingMeans ± SDStatistical significance by ANOVA (p values)
Complete retear (cRT)Partial retear (pRT)No retear (nRT)cRT vs. nRTcRT vs. pRTpRT vs. nRT
ER peak torque90°/s13.4 ± 1020.9 ± 6.318.1 ± 80.0430.021ns
180°/s8.6 ± 9.213.2 ± 6.513.1 ± 7.80.046nsns
270°/s6.3 ± 7.510.1 ± 5.79.2 ± 8.1nsnsns
360°/s0.3 ± 13 ± 5.82.5 ± 5nsnsns
ER PK/BW90°/s15 ± 1026.5 ± 11.822.4 ± 8.40.0030.001ns
180°/s9.1 ± 11.217.8 ± 616.1 ± 8.90.0070.02ns
270°/s6.2 ± 7.812.3 ± 7.211.7 ± 9.30.036nsns
360°/s0.3 ± 1.13.3 ± 6.63 ± 5.9nsnsns
ER average power90°/s9.9 ± 8.617.4 ± 515.1 ± 8.50.0290.027ns
180°/s7.6 ± 8.712 ± 7.213.2 ± 10.30.05nsns
270°/s4 ± 4.97.1 ± 7.76.5 ± 81nsnsns
360°/s0.1 ± 0.21.6 ± 3.71.4 ± 3.7nsnsns
ER total work90°/s28.5 ± 23.757.3 ± 22.848 ± 280.0120.008ns
180°/s14.4 ± 1631.9 ± 1528 ± 21.70.020.038ns
270°/s42.5 ± 40.185.1 ± 7161.6 ± 69nsnsns
360°/s0.1 ± 0.33.2 ± 7.64.2 ± 13.8nsnsns
IR peak torque90°/s22.7 ± 16.3534.2 ± 15.229.5 ± 12ns0.0310.03
180°/s13.9 ± 12.523.6 ± 1421.3 ± 10.6ns0.031ns
270°/s17.5 ± 13.824.2 ± 16.620.7 ± 11.1nsnsns
360°/s11 ± 9.217.9 ± 15.713.8 ± 9.5nsnsns
IR PK/BW90°/s25 ± 15.841 ± 13.435.9 ± 13.50.0050.004ns
180°/s13.8 ± 12.628 ± 13.326.4 ± 12.4nsnsns
270°/s17.5 ± 14.428 ± 15.225.1 ± 11.6nsnsns
360°/s10.6 ± 1020.1 ± 14.817.1 ± 11.2nsnsns
IR average Power90°/s18.3 ± 16.529.8 ± 16.322.9 ± 13.7ns0.047ns
180°/s10.5 ± 1524.3 ± 17.420.5 ± 15.80.0290.031ns
270°/s14.5 ± 17.926.9 ± 25.717.7 ± 15.1nsnsns
360°/s8.5 ± 12.318 ± 23.111 ± 13.3nsnsns
IR total work90°/s59.9 ± 54115.6 ± 61.981.6 ± 44.8ns0.0050.033
180°/s26.4 ± 3864.7 ± 40.952.3 ± 34.7nsnsns
270°/s35.4 ± 39.969.7 ± 72.259.8 ± 68.70.0130.009ns
360°/s15.3 ± 21.334.9 ± 38.722.2 ± 20.9ns0.047ns

ns not significant with p > 0.05

ER external rotation, IR internal rotation, PK/BW peak torque to body weight

Result of clinical evaluation ns not significant with p > 0.05 UCLA University of California in Los Angeles, SST simple shoulder test, SSI-ASES American Shoulder and Elbow Surgeons index Results of isometric shoulder testing by Forcemeter ns not significant with p > 0.05 Results of isokinetic shoulder testing by Biodex System 3 ns not significant with p > 0.05 ER external rotation, IR internal rotation, PK/BW peak torque to body weight Isometric testing showed the best results in the group with preserved integrity of RC tendons. In comparison, patients with complete retears had significantly weaker flexion, abduction, external and internal rotation. Partial retears did not make the patients weaker than the no-retear group. Isokinetic testing for external rotation revealed significantly lower values of peak torque, peak torque-to-body-weight, average work and total power when comparing the complete retear group to the remaining two at lower motion velocities (90°/s and 180°/s). Internal rotation testing also showed greater strength for more integrated repair site, however with less significant differences (Table 3).

Discussion

One of the most challenging issues in the rotator cuff repair is to obtain effective and permanent restoration of the tendon-to-bone junction. It is believed that it is not possible to restore the normal tendon-to-bone junction by surgical repair due to very unique structure and function of the junction [9, 10]. The tissue that grows at the tendon repair site has biomechanical properties that are inferior to normal rotator cuff insertion [10]. For that and other reasons lack of proper healing or retear occurs with reported frequency of the problem for 16–94 % of RC repairs [6-8]. Our study has shown incomplete rotator cuff healing after fixation in 26 % of the cases, out of which 16 % did not heal at all and 10 % of the cases healed partially. It is not quite clear whether the presence of rotator cuff tear or retear have clinical consequences. Asymptomatic rotator cuff tears have been reported by Scarlat and Florescu who showed up to 56 % asymptomatic cuff tears in healthy individuals over 75 years of age [11]. It is debatable whether the shoulder pain and weakness arise from the RC tear alone. Itoi et al. have shown that the intra-articular or intra-bursal injection of local anaesthetic led to increased strength measured by isokinetic testing [12]. Another study by Norlin and Adolfsson showed that patients with small full thickness tear do well following only arthroscopic decompression without repair [13]. Our study has specifically aimed at the impact of the RC tendon healing on subjective and objective measures of shoulder function. The healing was evaluated by ultrasound scan, which has been acknowledged as a reliable method of RC evaluation and has been used in similar studies before [7, 14, 15]. The study does not focus on possible risk factors of RC retear. As already described in other comparative studies the surgical technique had no effect on results in terms of cuff integrity. For the purpose of evaluation of cuff integrity on clinical results data of all patients have been pooled together both in this and other studies [6-8]. Patients’ clinical scores (pain, SSI, SST, UCLA, ROM) had improved significantly at follow-up compared to the preoperative status, regardless of the RC integrity at the insertion site. When comparing the results at the final follow-up, patients with a partial retear had slightly more pain compared to those with complete healing. Full-thickness retears did not lead to a significant increase in pain. Surprisingly, there were no significant differences in the shoulder scores related to the quality of healing. Complete retears had a negative effect on active elevation compared to the remaining two groups. Again, surprisingly no such effect could be found when active abduction and external rotation were measured. Basically, patients were satisfied no matter what quality of healing had been recorded ultimately. However, the most striking differences among the patients was revealed by objective measures. Static isometric testing of flexion and abduction had shown that shoulders with complete RC retear were weaker by 45 % compared to those with full tendon healing. More dynamic testing in the isokinetic mode had revealed 29–43 % deficits in peak external rotation torque comparing complete retear vs. normal healing. Patients’ ability to generate shoulder power and withstand a load proved to be lower in circumstances of a complete lack of healing (40–43 % and 34–55 %, respectively). Partial retears did not have a negative impact on the biomechanical properties of shoulders. Moreover, those patients also did better on testing than complete retears. As in our study, Yoo et al. and Liem had found a negative influence of retear on clinical results [16, 17]. In Liem’s study, shoulder abduction was decreased for cuffs with retear among open and arthroscopically repaired patients, yet significant differences were found only among the latter group. Zumstein et al. and Verma et al. found no difference in the outcome scores and pain level among patients with or without RC retear [7, 18]. In Verma’s study, patients with failed RC repair had significantly lower strength of forward flexion but not external rotation; and that was found regardless of the repair technique (arthroscopic vs. mini-open). Bishop et al., in a prospective study, examined RC integrity by also comparing arthoscopic versus open repair [6]. The authors found superior isometric testing results for flexion and external rotation as well as ASES and Constant score in the group with intact cuffs. Pain values remained improved following repair with no difference between preserved and retorn RC at the follow-up. They had also found that there was no significant difference in outcomes between open versus arthroscopic repair for any of the scores when the intact and retear groups were compared. Work by Millar et al. showed that regardless of the cuff integrity following repair parameters of pain, range of active motion, external and internal rotation strength improved with no significant differences [5]. However, patients with intact cuffs had better abduction strength and less pain on overhead activity. Demirors et al. found that the failed rotator cuff repair group showed lower levels of isokinetic extension and internal rotation. Despite high failure rate in their group functional results were satisfactory [19]. We have used more advanced and extensive biomechanical and objective measurements in this study including isometric and isokinetic evaluation. Isometric testing is a simple, quick and relatively inexpensive method of objective shoulder strength evaluation [20]. It allows for the detection of static strength deficits not being able to evaluate more advanced functionality. Isokinetic testing is more sophisticated, allowing a more functional evaluation [8]. It is possible to detect deficits in a moving shoulder and also reflects shoulder ability to generate power and performance of a working shoulder over time. Our study demonstrates that patients with complete retears are not only weaker in shoulder motion, but also are not able to perform work with different loads over a period of time. This may have an impact on the ability to return to heavy labour or sports. For those reasons, it seems that more objective measures should be introduced in populations that return to full activity. Possibly, for such patients, limitation of shoulder loading should be suggested. We have also looked at patients with partial retears (or partial healing). Those patients performed as well as those with normal healing in both subjective and objective evaluation. The only exception was a slightly higher pain level. A similar phenomenon had also been found among patients with partial RC tears that seem to experience more pain than those with full thickness tears, and in theory, cause abnormal tension to the remaining tendon fibres [21]. In our study this group showed otherwise good function and had comparable biomechanical abilities as patients with complete healing. Many studies and conference presentations have attempted to improve cuff integrity results by applying the double row or double row suture-bridge technique. The techniques seem to have superior biomechanical and biological properties [1-3]. Although the techniques do not prove to be clinically superior to single row fixation, they may have advantages in improving cuff integrity when the double row technique is used [1–3, 22–25]. Based on that and results of our study we should tend to obtain the best possible healing in patients with high biomechanical demands. Having good integrity leads to superior strength and endurance results. This issue might be important for heavy physical workers or athletes (not necessarily fully professional) wishing to get back to previous activity on a similar level. The physical performance of workers might be important information for employers bearing in mind both job safety, safe return to former duties and costs of work-related injuries. Proper testing and its results would help to determine time of returning to sports or heavy labour or establishing permanent limitations for future activity.

Conclusions

According to the results of this research rotator cuff integrity after open or arthroscopic repair does not seem to affect clinical scores. Recurrent tears may result in lower muscle performance in terms of active motion, strength and endurance. Advanced shoulder testing may be essential in assessing the patients’ ability to return to sports or heavy labour.
  25 in total

Review 1.  Single-row versus double-row rotator cuff repair: techniques and outcomes.

Authors:  Joshua S Dines; Asheesh Bedi; Neal S ElAttrache; David M Dines
Journal:  J Am Acad Orthop Surg       Date:  2010-02       Impact factor: 3.020

2.  The application of isokinetics in testing and rehabilitation of the shoulder complex.

Authors:  T S Ellenbecker; G J Davies
Journal:  J Athl Train       Date:  2000-07       Impact factor: 2.860

3.  Single-row versus double-row arthroscopic repair in the treatment of rotator cuff tears: a prospective randomized clinical study.

Authors:  Ignacio Carbonel; Angel Antonio Martinez; Angel Calvo; Jorge Ripalda; Antonio Herrera
Journal:  Int Orthop       Date:  2012-05-16       Impact factor: 3.075

4.  Correlations of isokinetic measurements with tendon healing following open repair of rotator cuff tears.

Authors:  Huseyin Demirors; Esra Circi; Rahmi Can Akgun; Nefise Cagla Tarhan; Nuri Cetin; Sercan Akpinar; Ismail Cengiz Tuncay
Journal:  Int Orthop       Date:  2009-06-16       Impact factor: 3.075

5.  A biomechanical comparison of 2 transosseous-equivalent double-row rotator cuff repair techniques using bioabsorbable anchors: cyclic loading and failure behavior.

Authors:  Jeffrey T Spang; Stefan Buchmann; Peter U Brucker; Panos Kouloumentas; Tobias Obst; Manuel Schröder; Rainer Burgkart; Andreas B Imhoff
Journal:  Arthroscopy       Date:  2009-08       Impact factor: 4.772

6.  Extracellular matrix scaffold devices for rotator cuff repair.

Authors:  Kathleen A Derwin; Stephen F Badylak; Scott P Steinmann; Joseph P Iannotti
Journal:  J Shoulder Elbow Surg       Date:  2010-02-26       Impact factor: 3.019

7.  Biomechanical comparison of 4 double-row suture-bridging rotator cuff repair techniques using different medial-row configurations.

Authors:  Stephan Pauly; Bettina Kieser; Alexander Schill; Christian Gerhardt; Markus Scheibel
Journal:  Arthroscopy       Date:  2010-06-11       Impact factor: 4.772

8.  Small full-thickness tears do well ten to thirteen years after arthroscopic subacromial decompression.

Authors:  Rolf Norlin; Lars Adolfsson
Journal:  J Shoulder Elbow Surg       Date:  2008 Jan-Feb       Impact factor: 3.019

9.  Rotator cuff defect healing: a biomechanical and histologic analysis in an animal model.

Authors:  J E Carpenter; S Thomopoulos; C L Flanagan; C M DeBano; L J Soslowsky
Journal:  J Shoulder Elbow Surg       Date:  1998 Nov-Dec       Impact factor: 3.019

10.  Rotator cuff integrity after arthroscopic repair for large tears with less-than-optimal footprint coverage.

Authors:  Jae Chul Yoo; Jin Hwan Ahn; Kyoung Hwan Koh; Kyung Sub Lim
Journal:  Arthroscopy       Date:  2009-10       Impact factor: 4.772

View more
  9 in total

1.  Association between pre-operative magnetic resonance imaging and reparability of large and massive rotator cuff tears.

Authors:  Tim Dwyer; Helen Razmjou; Patrick Henry; Simon Gosselin-Fournier; Richard Holtby
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-10-30       Impact factor: 4.342

2.  Rotational glenohumeral adaptations are associated with shoulder pathology in professional male handball players.

Authors:  Przemyslaw Lubiatowski; Piotr Kaczmarek; Pawel Cisowski; Ewa Breborowicz; Monika Grygorowicz; Marcin Dzianach; Tomasz Krupecki; Lior Laver; Leszek Romanowski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-02-15       Impact factor: 4.342

3.  Capstan screw rotator cuff repair: a novel two-row mini-open technique.

Authors:  Paul Guyver; Alex Goubran; Aishling Jaques; Christopher Smith; Tim Bunker
Journal:  Shoulder Elbow       Date:  2014-06-17

4.  Rotator cuff repair with a tendon-fibrocartilage-bone composite bridging patch.

Authors:  Xiaoxi Ji; Qingshan Chen; Andrew R Thoreson; Jin Qu; Kai-Nan An; Peter C Amadio; Scott P Steinmann; Chunfeng Zhao
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-07-04       Impact factor: 2.063

5.  Predictors of disease-specific quality of life after arthroscopic rotator cuff repair.

Authors:  Arjen Kolk; Nienke Wolterbeek; Kiem Gie Auw Yang; Jacco A C Zijl; Ronald N Wessel
Journal:  Int Orthop       Date:  2015-10-27       Impact factor: 3.075

6.  Volumetric MicroCT Intensity Histograms of Fatty Infiltration Correlate with the Mechanical Strength of Rotator Cuff Repairs: An Ex Vivo Rabbit Model.

Authors:  Phillip E McClellan; Lekha Kesavan; Yujing Wen; Jason Ina; Derrick M Knapik; Robert J Gillespie; Ozan Akkus; Victoria A Webster-Wood
Journal:  Clin Orthop Relat Res       Date:  2021-02-01       Impact factor: 4.755

7.  Summary of Meta-Analyses Dealing with Single-Row versus Double-Row Repair Techniques for Rotator Cuff Tears.

Authors:  U J Spiegl; S A Euler; P J Millett; P Hepp
Journal:  Open Orthop J       Date:  2016-07-21

Review 8.  The Impact of Re-tear on the Clinical Outcome after Rotator Cuff Repair Using Open or Arthroscopic Techniques - A Systematic Review.

Authors:  Ilias Galanopoulos; Aslanidis Ilias; Konstantinos Karliaftis; Dimitrios Papadopoulos; Neil Ashwood
Journal:  Open Orthop J       Date:  2017-02-28

9.  Shoulder proprioception following reverse total shoulder arthroplasty.

Authors:  Joanna Walecka; Przemysław Lubiatowski; Paolo Consigliere; Ehud Atoun; Ofer Levy
Journal:  Int Orthop       Date:  2020-08-15       Impact factor: 3.075

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.