Literature DB >> 23948730

Experimental characterization of two-dimensional pencil beam scanning proton spot profiles.

Liyong Lin1, Christopher G Ainsley, James E McDonough.   

Abstract

Dose calculations of pencil beam scanning treatment plans rely on the accuracy of proton spot profiles; not only the primary component but also the broad tail components. Four films are placed at several locations in air and multiple depths in Solidwater® for six selected energies. The films used for the primary components are exposed to 50-200 MU to avoid saturation; the films used for the tail components are exposed to 800, 8000 and 80,000 MU. By applying a pair/magnification method and merging these data, dose kernels down to 10(-4) of the central spot dose can be generated. From these kernels one can calculate the dose-per-MU for different field sizes and shapes. Measurements agree within 1% of dose-kernel-based calculations for output versus field size comparisons. Asymmetric, comet-shaped profile tails have a bigger impact at superficial depths and low energies: the output difference between two orientations at the surface of a rectangular field of 40 mm×200 mm is about 2% at the isocentre at 100 MeV. Integration of these dose kernels from 0 to 40 mm radius shows that the charge deficit in the Bragg peak chamber varies <2% from entrance to the end of range for energies <180 MeV, but exceeds 5% at 225 MeV.

Entities:  

Mesh:

Year:  2013        PMID: 23948730     DOI: 10.1088/0031-9155/58/17/6193

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  11 in total

1.  Toward improved target conformity for two spot scanning proton therapy delivery systems using dynamic collimation.

Authors:  Alexandra Moignier; Edgar Gelover; Blake R Smith; Dongxu Wang; Ryan T Flynn; Maura L Kirk; Liyong Lin; Timothy D Solberg; Alexander Lin; Daniel E Hyer
Journal:  Med Phys       Date:  2016-03       Impact factor: 4.071

2.  Experimental and Monte Carlo characterization of a dynamic collimation system prototype for pencil beam scanning proton therapy.

Authors:  Blake R Smith; Mark Pankuch; Daniel E Hyer; Wesley S Culberson
Journal:  Med Phys       Date:  2020-09-09       Impact factor: 4.071

3.  A method for modeling laterally asymmetric proton beamlets resulting from collimation.

Authors:  Edgar Gelover; Dongxu Wang; Patrick M Hill; Ryan T Flynn; Mingcheng Gao; Steve Laub; Mark Pankuch; Daniel E Hyer
Journal:  Med Phys       Date:  2015-03       Impact factor: 4.071

4.  Improving Head and Neck Cancer Treatments Using Dynamic Collimation in Spot Scanning Proton Therapy.

Authors:  Alexandra Moignier; Edgar Gelover; Dongxu Wang; Blake Smith; Ryan Flynn; Maura Kirk; Liyong Lin; Timothy Solberg; Alexander Lin; Daniel Hyer
Journal:  Int J Part Ther       Date:  2016-03-24

5.  Comparing proton treatment plans of pediatric brain tumors in two pencil beam scanning nozzles with different spot sizes.

Authors:  John C Kralik; Liwen Xi; Timothy D Solberg; Charles B Simone; Liyong Lin
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

6.  Beam-specific planning target volumes incorporating 4D CT for pencil beam scanning proton therapy of thoracic tumors.

Authors:  Liyong Lin; Minglei Kang; Sheng Huang; Rulon Mayer; Andrew Thomas; Timothy D Solberg; James E McDonough; Charles B Simone
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

7.  Comparison of multi-institutional Varian ProBeam pencil beam scanning proton beam commissioning data.

Authors:  Ulrich W Langner; John G Eley; Lei Dong; Katja Langen
Journal:  J Appl Clin Med Phys       Date:  2017-04-19       Impact factor: 2.102

8.  Commissioning of the world's first compact pencil-beam scanning proton therapy system.

Authors:  Rajesh Pidikiti; Bijal C Patel; Matthew R Maynard; Joseph P Dugas; Joseph Syh; Narayan Sahoo; Hsinshun Terry Wu; Lane R Rosen
Journal:  J Appl Clin Med Phys       Date:  2017-11-20       Impact factor: 2.102

9.  Clinical Validation of a Ray-Casting Analytical Dose Engine for Spot Scanning Proton Delivery Systems.

Authors:  James E Younkin; Danairis Hernandez Morales; Jiajian Shen; Jie Shan; Martin Bues; Jarrod M Lentz; Steven E Schild; Joshua B Stoker; Xiaoning Ding; Wei Liu
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec

10.  Innovations and the Use of Collimators in the Delivery of Pencil Beam Scanning Proton Therapy.

Authors:  Daniel E Hyer; Laura C Bennett; Theodore J Geoghegan; Martin Bues; Blake R Smith
Journal:  Int J Part Ther       Date:  2021-06-25
View more