We demonstrate intravascular optical coherence tomography (OCT) imaging with frame rate up to 3.2 kHz (192,000 rpm scanning). This was achieved by using a custom-built catheter in which the circumferential scanning was actuated by a 1.0 mm diameter synchronous motor. The OCT system, with an imaging depth of 3.7 mm (in air), is based on a Fourier domain mode locked laser operating at an A-line rate of 1.6 MHz. The diameter of the catheter is 1.1 mm at the tip. Ex vivo images of human coronary artery (78.4 mm length) were acquired at a pullback speed of 100 mm/s. True 3D volumetric imaging of the entire artery, with dense and isotropic sampling in all dimensions, was performed in <1 second acquisition time.

Entities:  

Mesh:

Year:  2013        PMID: 23938921     DOI: 10.1364/OL.38.001715

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  29 in total

1.  Correction of rotational distortion for catheter-based en face OCT and OCT angiography.

Authors:  Osman O Ahsen; Hsiang-Chieh Lee; Michael G Giacomelli; Zhao Wang; Kaicheng Liang; Tsung-Han Tsai; Benjamin Potsaid; Hiroshi Mashimo; James G Fujimoto
Journal:  Opt Lett       Date:  2014-10-15       Impact factor: 3.776

2.  Heartbeat OCT: in vivo intravascular megahertz-optical coherence tomography.

Authors:  Tianshi Wang; Tom Pfeiffer; Evelyn Regar; Wolfgang Wieser; Heleen van Beusekom; Charles T Lancee; Geert Springeling; Ilona Krabbendam; Antonius F W van der Steen; Robert Huber; Gijs van Soest
Journal:  Biomed Opt Express       Date:  2015-11-23       Impact factor: 3.732

3.  Ultrahigh speed en face OCT capsule for endoscopic imaging.

Authors:  Kaicheng Liang; Giovanni Traverso; Hsiang-Chieh Lee; Osman Oguz Ahsen; Zhao Wang; Benjamin Potsaid; Michael Giacomelli; Vijaysekhar Jayaraman; Ross Barman; Alex Cable; Hiroshi Mashimo; Robert Langer; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2015-03-05       Impact factor: 3.732

4.  Miniaturized magnetic-driven scanning probe for endoscopic optical coherence tomography.

Authors:  Ziwei Pang; Jigang Wu
Journal:  Biomed Opt Express       Date:  2015-05-26       Impact factor: 3.732

5.  Wavelength shifting of intra-cavity photons: Adiabatic wavelength tuning in rapidly wavelength-swept lasers.

Authors:  Christian Jirauschek; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-06-12       Impact factor: 3.732

6.  Developing cross-correlation as a method for microvessel imaging using clinical intravascular optical coherence tomography systems.

Authors:  Shiju Joseph; Asif Adnan; Hrebesh M Subhash; Martin Leahy; David Adlam
Journal:  Biomed Opt Express       Date:  2015-02-03       Impact factor: 3.732

7.  Single cardiac cycle three-dimensional intracoronary optical coherence tomography.

Authors:  Tae Shik Kim; Hyun-Sang Park; Sun-Joo Jang; Joon Woo Song; Han Saem Cho; Sunwon Kim; Brett E Bouma; Jin Won Kim; Wang-Yuhl Oh
Journal:  Biomed Opt Express       Date:  2016-11-01       Impact factor: 3.732

8.  Correction of circumferential and longitudinal motion distortion in high-speed catheter/endoscope-based optical coherence tomography.

Authors:  Tan Huu Nguyen; Osman Oguz Ahsen; Kaicheng Liang; Jason Zhang; Hiroshi Mashimo; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2020-12-09       Impact factor: 3.732

9.  Flexible A-scan rate MHz-OCT: efficient computational downscaling by coherent averaging.

Authors:  Tom Pfeiffer; Madita Göb; Wolfgang Draxinger; Sebastian Karpf; Jan Philip Kolb; Robert Huber
Journal:  Biomed Opt Express       Date:  2020-10-29       Impact factor: 3.732

10.  Endoscopic optical coherence tomography: technologies and clinical applications [Invited].

Authors:  Michalina J Gora; Melissa J Suter; Guillermo J Tearney; Xingde Li
Journal:  Biomed Opt Express       Date:  2017-04-07       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.