Literature DB >> 23934534

[Mono- versus polyaxial locking plates].

M Hanschen1, P Biberthaler.   

Abstract

Conventional plate osteosynthesis is undergoing a period of transition. The concept of locking plate osteosynthesis is of special importance. Monoaxial locking plate osteosynthesis has shown promising results (rapid bone healing via callus, minimal soft tissue irritation, advantageous in osteoporosis). Some implants allow for polyaxial locking. The first results of comparative studies concerning biomechanics and clinical outcome of mono- versus polyaxial locking plates are presented.

Entities:  

Mesh:

Year:  2013        PMID: 23934534     DOI: 10.1007/s00113-013-2451-9

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  21 in total

Review 1.  Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology.

Authors:  Stephan M Perren
Journal:  J Bone Joint Surg Br       Date:  2002-11

2.  Clinical outcome and complications using a polyaxial locking plate in the treatment of displaced proximal humerus fractures. A reliable system?

Authors:  M Königshausen; L Kübler; H Godry; M Citak; T A Schildhauer; D Seybold
Journal:  Injury       Date:  2011-10-14       Impact factor: 2.586

3.  Biological internal fixation of fractures.

Authors:  C Gerber; J W Mast; R Ganz
Journal:  Arch Orthop Trauma Surg       Date:  1990       Impact factor: 3.067

4.  Effects of percutaneous and conventional plating techniques on the blood supply to the femur.

Authors:  O Farouk; C Krettek; T Miclau; P Schandelmaier; H Tscherne
Journal:  Arch Orthop Trauma Surg       Date:  1998       Impact factor: 3.067

5.  Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study.

Authors:  Christine Voigt; Andreas Geisler; Pierre Hepp; Arndt P Schulz; Helmut Lill
Journal:  J Orthop Trauma       Date:  2011-10       Impact factor: 2.512

6.  Clinical experience with a new compression plate "DCP".

Authors:  M Allgöwer; R Ehrsam; R Ganz; P Matter; S M Perren
Journal:  Acta Orthop Scand Suppl       Date:  1969

7.  Minimally invasive plate osteosynthesis and vascularity: preliminary results of a cadaver injection study.

Authors:  O Farouk; C Krettek; T Miclau; P Schandelmaier; P Guy; H Tscherne
Journal:  Injury       Date:  1997       Impact factor: 2.586

Review 8.  Fracture healing. The evolution of our understanding.

Authors:  Stephan M Perren
Journal:  Acta Chir Orthop Traumatol Cech       Date:  2008-08       Impact factor: 0.531

9.  [Experiences in the treatment of midfacial fractures using a fixed-angle osteosynthetic system. Biomechanical results].

Authors:  S Flinzberg; M Heiland; M Vesper; K Seide; D Wolter; N Weinrich; R Schmelzle
Journal:  Mund Kiefer Gesichtschir       Date:  2004-04-06

Review 10.  Locking plate technology and its role in osteoporotic fractures.

Authors:  Michael A Miranda
Journal:  Injury       Date:  2007-09       Impact factor: 2.586

View more
  6 in total

1.  [Risk factors for failure of osteosynthesis. After periprosthetic fractures of the knee joint].

Authors:  M Hanschen; P Biberthaler
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

2.  Re: Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial.

Authors:  Marc Hanschen; Peter Biberthaler
Journal:  Int Orthop       Date:  2014-06-08       Impact factor: 3.075

Review 3.  [Osteosynthesis after periprosthetic fractures of the knee joint].

Authors:  F von Matthey; S Ruchholtz; P Biberthaler; M Hanschen
Journal:  Unfallchirurg       Date:  2016-04       Impact factor: 1.000

4.  Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial.

Authors:  Marc Hanschen; Ina M Aschenbrenner; Kai Fehske; Sonja Kirchhoff; Leonhard Keil; Boris M Holzapfel; Sebastian Winkler; Bernd Fuechtmeier; Rainer Neugebauer; Sven Luehrs; Ulrich Liener; Peter Biberthaler
Journal:  Int Orthop       Date:  2013-12-11       Impact factor: 3.075

5.  Clinical and radiological outcome following treatment of displaced lateral clavicle fractures using a locking compression plate with lateral extension: a prospective study.

Authors:  Marc Beirer; Sebastian Siebenlist; Moritz Crönlein; Lukas Postl; Stefan Huber-Wagner; Peter Biberthaler; Chlodwig Kirchhoff
Journal:  BMC Musculoskelet Disord       Date:  2014-11-19       Impact factor: 2.362

6.  Outcome after polyaxial locking plate osteosynthesis in proximal tibia fractures: a prospective clinical trial.

Authors:  Dominik Völk; Markus Neumaier; Heike Einhellig; Peter Biberthaler; Marc Hanschen
Journal:  BMC Musculoskelet Disord       Date:  2021-03-18       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.