Literature DB >> 15138852

[Experiences in the treatment of midfacial fractures using a fixed-angle osteosynthetic system. Biomechanical results].

S Flinzberg1, M Heiland, M Vesper, K Seide, D Wolter, N Weinrich, R Schmelzle.   

Abstract

AIM: Fixed-angle osteosynthetic systems are characterized by mechanical "locking" of the osteosynthetic screw and plate. These systems have found increasing acceptance and use for osteosynthetic fixation and temporary reconstruction of the mandible. The aim of this study was to investigate the applicability and performance of fixed-angle systems in the treatment of midfacial fractures. MATERIAL AND
METHOD: A newly developed fixed-angle osteosynthetic plate system (smart lock) was compared to a conventional system using fresh human skulls. The iatrogenically produced zygomatic fractures of the human skulls were treated by osteosynthesis and biomechanically tested. Furthermore, in a dynamic test series, an artificial bone was subjected to an alternating force of 15 N of up to 1,000,000 cycles. The new screws and plates were subjected to further biomechanical tests.
RESULTS: The tests using the fixed-angle implants revealed that an increase of stability of up to 40% can be expected after osteosynthetic fixation. Furthermore, the plates resisted 1,000,000 cycles of alternating forces, whereby the conventional systems failed after 170,000 cycles on the average.
CONCLUSION: Fixed-angle systems, due to their construction, provide a high degree of stability even in thin bones of the midface. They appear to be promising for the treatment of midfacial fractures.

Entities:  

Mesh:

Year:  2004        PMID: 15138852     DOI: 10.1007/s10006-004-0540-1

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  10 in total

1.  A comparative study on four screw-plate locking systems in sheep: a clinical and radiological study.

Authors:  C Lindqvist; A L Söderholm; A Salo; J Subasinghe; S Ylijoki; K Skutnabb; D Hallikainen
Journal:  Int J Oral Maxillofac Surg       Date:  2001-04       Impact factor: 2.789

2.  Does plate adaptation affect stability? A biomechanical comparison of locking and nonlocking plates.

Authors:  Richard H Haug; Chad C Street; Michele Goltz
Journal:  J Oral Maxillofac Surg       Date:  2002-11       Impact factor: 1.895

3.  Bridging of mandibular defects with two different reconstruction systems: an experimental study.

Authors:  A L Söderholm; C Lindqvist; K Skutnabb; B Rahn
Journal:  J Oral Maxillofac Surg       Date:  1991-10       Impact factor: 1.895

4.  [The effect of an angle-stable plate-screw connection and various screw diameters on the stability of plate osteosynthesis. An FE model study].

Authors:  K Seide; W Zierold; D Wolter; H R Kortmann
Journal:  Unfallchirurg       Date:  1990-12       Impact factor: 1.000

5.  The sphenozygomatic suture as a key site for osteosynthesis of the orbitozygomatic complex in panfacial fractures: a biomechanical study in human cadavers based on clinical practice.

Authors:  Dennis Rohner; Andrew Tay; Chung Sew Meng; Dietmar W Hutmacher; Beat Hammer
Journal:  Plast Reconstr Surg       Date:  2002-11       Impact factor: 4.730

6.  Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects.

Authors:  J Raveh; F Sutter; S Hellem
Journal:  Otolaryngol Clin North Am       Date:  1987-08       Impact factor: 3.346

7.  Analysis of seating and fracturing torque of bicortical screws.

Authors:  J A Ellis; D M Laskin
Journal:  J Oral Maxillofac Surg       Date:  1994-05       Impact factor: 1.895

8.  Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects.

Authors:  J Raveh; H Stich; F Sutter; R Greiner
Journal:  J Oral Maxillofac Surg       Date:  1984-05       Impact factor: 1.895

9.  [Morbidity analysis of 1484 facial bone fractures between 1968 and 1987].

Authors:  D Prokop; H H Boeckler
Journal:  Dtsch Z Mund Kiefer Gesichtschir       Date:  1990 Jul-Aug

10.  [3-dimensional imaging possibilities of thhe mid-face area using digital volume tomography based on a daver study of angle stable osteosynthesis].

Authors:  S Flinzberg; R Schmelzle; D Schulze; U Rother; M Heiland
Journal:  Mund Kiefer Gesichtschir       Date:  2003-08-15
  10 in total
  2 in total

1.  [Mono- versus polyaxial locking plates].

Authors:  M Hanschen; P Biberthaler
Journal:  Unfallchirurg       Date:  2013-08       Impact factor: 1.000

2.  [Midfacial fractures. Diagnosis and treatment].

Authors:  M Bärmann; N Stasche
Journal:  HNO       Date:  2011-11       Impact factor: 1.284

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.