Literature DB >> 23928092

Thousand-fold fluorescent signal amplification for mHealth diagnostics.

Joshua Balsam1, Reuven Rasooly, Hugh Alan Bruck, Avraham Rasooly.   

Abstract

The low sensitivity of Mobile Health (mHealth) optical detectors, such as those found on mobile phones, is a limiting factor for many mHealth clinical applications. To improve sensitivity, we have combined two approaches for optical signal amplification: (1) a computational approach based on an image stacking algorithm to decrease the image noise and enhance weak signals, and (2) an optical signal amplifier utilizing a capillary tube array. These approaches were used in a detection system which includes multi-wavelength LEDs capable of exciting many fluorophores in multiple wavelengths, a mobile phone or a webcam as a detector, and capillary tube array configured with 36 capillary tubes for signal enhancement. The capillary array enables a ~100× increase in signal sensitivity for fluorescein, reducing the limit of detection (LOD) for mobile phones and webcams from 1000 nM to 10nM. Computational image stacking enables another ~10× increase in signal sensitivity, further reducing the LOD for webcam from 10nM to 1 nM. To demonstrate the feasibility of the device for the detection of disease-related biomarkers, adenovirus DNA labeled with SYBR green or fluorescein was analyzed by both our capillary array and a commercial plate reader. The LOD for the capillary array was 5 ug/mL, and that of the plate reader was 1 ug/mL. Similar results were obtained using DNA stained with fluorescein. The combination of the two signal amplification approaches enables a ~1000× increase in LOD for the webcam platform. This brings it into the range of a conventional plate reader while using a smaller sample volume (10 ul) than the plate reader requires (100 ul). This suggests that such a device could be suitable for biosensing applications where up to 10 fold smaller sample sizes are needed. The simple optical configuration for mHealth described in this paper employing the combined capillary and image processing signal amplification is capable of measuring weak fluorescent signals without the need of dedicated laboratories. It has the potential to be used to increase sensitivity of other optically based mHealth technologies, and may increase mHealth's clinical utility, especially for telemedicine and for resource-poor settings and global health applications. Published by Elsevier B.V.

Entities:  

Keywords:  Capillary; Fluorescence; Image stacking; Lab-on-a-chip; Mobile phone; mHealth

Mesh:

Substances:

Year:  2013        PMID: 23928092      PMCID: PMC3795847          DOI: 10.1016/j.bios.2013.06.053

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  34 in total

1.  Array biosensor for simultaneous identification of bacterial, viral, and protein analytes.

Authors:  C A Rowe; L M Tender; M J Feldstein; J P Golden; S B Scruggs; B D MacCraith; J J Cras; F S Ligler
Journal:  Anal Chem       Date:  1999-09-01       Impact factor: 6.986

2.  Multi-analyte interrogation using the fiber optic biosensor.

Authors:  G P Anderson; K D King; K L Gaffney; L H Johnson
Journal:  Biosens Bioelectron       Date:  2000-01       Impact factor: 10.618

3.  Wide-field fluorescent microscopy on a cell-phone.

Authors:  Hongying Zhu; Oguzhan Yaglidere; Ting-Wei Su; Derek Tseng; Aydogan Ozcan
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

Review 4.  Point-of-care diagnostics for global health.

Authors:  Paul Yager; Gonzalo J Domingo; John Gerdes
Journal:  Annu Rev Biomed Eng       Date:  2008       Impact factor: 9.590

5.  Mass-sensing, multianalyte microarray immunoassay with imaging detection.

Authors:  J W Silzel; B Cercek; C Dodson; T Tsay; R J Obremski
Journal:  Clin Chem       Date:  1998-09       Impact factor: 8.327

6.  Detection of multiple toxic agents using a planar array immunosensor.

Authors:  R M Wadkins; J P Golden; L M Pritsiolas; F S Ligler
Journal:  Biosens Bioelectron       Date:  1998-03-01       Impact factor: 10.618

7.  A multi-band capillary immunosensor.

Authors:  K Misiakos; S E Kakabakos
Journal:  Biosens Bioelectron       Date:  1998-10-01       Impact factor: 10.618

8.  Lensfree microscopy on a cellphone.

Authors:  Derek Tseng; Onur Mudanyali; Cetin Oztoprak; Serhan O Isikman; Ikbal Sencan; Oguzhan Yaglidere; Aydogan Ozcan
Journal:  Lab Chip       Date:  2010-05-06       Impact factor: 6.799

9.  Optofluidic fluorescent imaging cytometry on a cell phone.

Authors:  Hongying Zhu; Sam Mavandadi; Ahmet F Coskun; Oguzhan Yaglidere; Aydogan Ozcan
Journal:  Anal Chem       Date:  2011-08-02       Impact factor: 6.986

10.  Lab-on-a-chip for botulinum neurotoxin a (BoNT-A) activity analysis.

Authors:  Steven Sun; Miguel Ossandon; Yordan Kostov; Avraham Rasooly
Journal:  Lab Chip       Date:  2009-09-17       Impact factor: 6.799

View more
  7 in total

Review 1.  Genosensors as an alternative diagnostic sensing approaches for specific detection of virus species: A review of common techniques and outcomes.

Authors:  Abouzar Babaei; Amir Pouremamali; Nastaran Rafiee; Hessamaddin Sohrabi; Ahad Mokhtarzadeh; Miguel de la Guardia
Journal:  Trends Analyt Chem       Date:  2022-05-19       Impact factor: 14.908

2.  The Assessment of the Readiness of Molecular Biomarker-Based Mobile Health Technologies for Healthcare Applications.

Authors:  Chu Qin; Lin Tao; Yik Hui Phang; Cheng Zhang; Shang Ying Chen; Peng Zhang; Ying Tan; Yu Yang Jiang; Yu Zong Chen
Journal:  Sci Rep       Date:  2015-12-08       Impact factor: 4.379

3.  Ultrasensitive, rapid and inexpensive detection of DNA using paper based lateral flow assay.

Authors:  Miriam Jauset-Rubio; Markéta Svobodová; Teresa Mairal; Calum McNeil; Neil Keegan; Ayman Saeed; Mohammad Nooredeen Abbas; Mohammad S El-Shahawi; Abdulaziz S Bashammakh; Abdulrahman O Alyoubi; Ciara K O Sullivan
Journal:  Sci Rep       Date:  2016-11-25       Impact factor: 4.379

4.  Transformation of personal computers and mobile phones into genetic diagnostic systems.

Authors:  Faye M Walker; Kareem M Ahmad; Michael Eisenstein; H Tom Soh
Journal:  Anal Chem       Date:  2014-08-31       Impact factor: 6.986

Review 5.  Improving the Sensitivity and Functionality of Mobile Webcam-Based Fluorescence Detectors for Point-of-Care Diagnostics in Global Health.

Authors:  Reuven Rasooly; Hugh Alan Bruck; Joshua Balsam; Ben Prickril; Miguel Ossandon; Avraham Rasooly
Journal:  Diagnostics (Basel)       Date:  2016-05-17

Review 6.  The role of interdisciplinary research team in the impact of health apps in health and computer science publications: a systematic review.

Authors:  Guillermo Molina Recio; Laura García-Hernández; Rafael Molina Luque; Lorenzo Salas-Morera
Journal:  Biomed Eng Online       Date:  2016-07-15       Impact factor: 2.819

Review 7.  Smartphone-based clinical diagnostics: towards democratization of evidence-based health care.

Authors:  I Hernández-Neuta; F Neumann; J Brightmeyer; T Ba Tis; N Madaboosi; Q Wei; A Ozcan; M Nilsson
Journal:  J Intern Med       Date:  2018-09-12       Impact factor: 8.989

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.