Literature DB >> 9642774

Detection of multiple toxic agents using a planar array immunosensor.

R M Wadkins1, J P Golden, L M Pritsiolas, F S Ligler.   

Abstract

A planar array immunosensor, equipped with a charge-coupled device (CCD) as a detector, was used to simultaneously detect 3 toxic analytes. Wells approximately 2 mm in diameter were formed on glass slides using a photoactivated optical adhesive. Antibodies against staphylococcal enterotoxin B (SEB), ricin, and Yersinia pestis were covalently attached to the bottoms of the circular wells to form the sensing surface. Rectangular wells containing chicken immunoglobulin were used as alignment markers and to generate control signals. After removing the optical adhesive, the slides were mounted over a scientific grade CCD operating at ambient temperature in inverted (multipin phasing) mode. A two-dimensional graded index of refraction lens array was used to focus the sensing surface onto the CCD. Solutions of toxins were then placed on the slide. After rinsing, Cy5-labeled antibodies were introduced. The identity and amount of toxin bound at each location on the slide were determined by quantitative image analysis. Concentrations as low as 25 ng/mL of ricin, 15 ng/mL of pestis F1 antigen, and 5 ng/mL of SEB could be routinely measured.

Entities:  

Mesh:

Year:  1998        PMID: 9642774     DOI: 10.1016/s0956-5663(97)00113-9

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

Review 1.  Principles of affinity-based biosensors.

Authors:  K R Rogers
Journal:  Mol Biotechnol       Date:  2000-02       Impact factor: 2.695

2.  A portable array biosensor for detecting multiple analytes in complex samples.

Authors:  C R Taitt; J P Golden; Y S Shubin; L C Shriver-Lake; K E Sapsford; A Rasooly; F S Ligler
Journal:  Microb Ecol       Date:  2004-02-09       Impact factor: 4.552

3.  Multiplexed detection of bacteria and toxins using a microflow cytometer.

Authors:  Jason S Kim; George P Anderson; Jeffrey S Erickson; Joel P Golden; Mansoor Nasir; Frances S Ligler
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

4.  Detection of Salmonella enterica serovar typhimurium by using a rapid, array-based immunosensor.

Authors:  Chris Rowe Taitt; Yura S Shubin; Roselina Angel; Frances S Ligler
Journal:  Appl Environ Microbiol       Date:  2004-01       Impact factor: 4.792

5.  Thousand-fold fluorescent signal amplification for mHealth diagnostics.

Authors:  Joshua Balsam; Reuven Rasooly; Hugh Alan Bruck; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2013-07-17       Impact factor: 10.618

6.  Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2013-09       Impact factor: 7.460

  6 in total