Literature DB >> 23926585

Manual versus sonic-powered toothbrushing for plaque reduction in patients with dental implants: an explanatory randomised controlled trial.

Katrin Swierkot1, Manuel Brusius, Diana Leismann, Claudia Nonnenmacher, Rolf Nüsing, Dirk Lubbe, Carmen Schade-Brittinger, Reiner Mengel.   

Abstract

PURPOSE: The aim of the present study was to investigate plaque levels following sonic-powered and manual toothbrushing in subjects with dental implants.
MATERIALS AND METHODS: This study included 36 male and 47 female partially edentulous patients (age range 45-78 years, mean age 59.8 years) that were randomly assigned to one of two treatment groups: the sonic toothbrush group (n = 42; Philips Sonicare FlexCare® toothbrush) or the manual toothbrush group (n = 41; Oral-B P40®). Clinical, microbiological and immunological examinations were performed blinded at baseline and after 3, 6, 9 and 12 months. Microbiological analyses were performed by real-time polymerase chain reaction. Immunological analyses (prostaglandin E2) were performed by chromatography-electrospray spectrometry.
RESULTS: The plaque index difference between baseline and 12 months at implants showed no significant difference between sonic or manual toothbrushing in a two-sided Mann-Whitney test (W = 773.5, P = 0.426, 95% CI -0.64 to 0.20). At the end of the study, there were no significant changes in plaque index, bleeding on probing, gingival index, pocket probing depth, gingival recession, clinical attachment level or the microbiological and immunological outcomes at implants or teeth in either group.
CONCLUSIONS: This study uncovered no significant difference between sonic and manual toothbrushing for plaque reduction at implants and teeth. Both toothbrushes maintain healthy peri-implant soft tissue.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23926585

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  5 in total

1.  Brushing associated with oral irrigation in maintaining implants and overdentures hygiene - a randomized clinical trial.

Authors:  Marcela Moreira Salles; Viviane de Cássia Oliveira; Ana Paula Macedo; Cássio do Nascimento; Cláudia Helena Silva-Lovato; Helena de Freitas Oliveira Paranhos
Journal:  Odontology       Date:  2020-08-04       Impact factor: 2.634

Review 2.  Powered versus manual toothbrushing for oral health.

Authors:  Munirah Yaacob; Helen V Worthington; Scott A Deacon; Chris Deery; A Damien Walmsley; Peter G Robinson; Anne-Marie Glenny
Journal:  Cochrane Database Syst Rev       Date:  2014-06-17

3.  Efficacy of sonic-powered toothbrushes for plaque removal in patients with peri-implant mucositis.

Authors:  Jungwon Lee; Jong Heun Lim; Jungeun Lee; Sungtae Kim; Ki-Tae Koo; Yang-Jo Seol; Young Ku; Yong-Moo Lee; In-Chul Rhyu
Journal:  J Periodontal Implant Sci       Date:  2015-04-29       Impact factor: 2.614

Review 4.  Microbial Profiles and Detection Techniques in Peri-Implant Diseases: a Systematic Review.

Authors:  Miguel Padial-Molina; Jesús López-Martínez; Francisco O'Valle; Pablo Galindo-Moreno
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

Review 5.  Non-Surgical Therapy for Peri-Implant Diseases: a Systematic Review.

Authors:  Fernando Suárez-López Del Amo; Shan-Huey Yu; Hom-Lay Wang
Journal:  J Oral Maxillofac Res       Date:  2016-09-09