| Literature DB >> 25932339 |
Jungwon Lee1, Jong Heun Lim2, Jungeun Lee1, Sungtae Kim1, Ki-Tae Koo1, Yang-Jo Seol1, Young Ku1, Yong-Moo Lee1, In-Chul Rhyu1.
Abstract
PURPOSE: The aim of this study was to evaluate the effectiveness of powered toothbrushes for plaque control in patients with peri-implant mucositis, in comparison with manual toothbrushes.Entities:
Keywords: Dental implant; Dental plaque; Oral hygiene
Year: 2015 PMID: 25932339 PMCID: PMC4415002 DOI: 10.5051/jpis.2015.45.2.56
Source DB: PubMed Journal: J Periodontal Implant Sci ISSN: 2093-2278 Impact factor: 2.614
Description of subjects and implants by toothbrush group.
| Subject/implant characteristics | Toothbrush group | |
|---|---|---|
| Manual | Powered | |
| Gender | ||
| Male | 11 | 12 |
| Female | 9 | 8 |
| Subtotal | 20 | 20 |
| Age (year) | ||
| Mean (SD) | 54.5 (10.6) | 54.6 (11.7) |
| Range | 39-75 | 27-75 |
| Number of implants | ||
| Total (all subjects) | 33 | 30 |
| Mean per subject (SD) | 1.65 (0.75) | 1.50 (0.76) |
| Range | 1-4 | 1-3 |
| Time since implant restoration (year) | ||
| Mean (SD) | 5.6 (2.8) | 4.8 (2.9) |
| Range | 2.7-9.0 | 3.2-8.1 |
| Time since implant placement (year) | ||
| Mean (SD) | 6.4 (3.1) | 6.2 (2.5) |
| Range | 3.0-9.6 | 3.6-8.7 |
SD: standard deviation.
Oral hygiene habits and compliance at baseline, one month, and two months.
| Oral hygiene habit | Manual tooth brush | Powered tooth brush | ||||
|---|---|---|---|---|---|---|
| Baseline | 1 month | 2 months | Baseline | 1 month | 2 months | |
| Frequency of brushing per day | 2.33 (0.56) | 2.58 (0.50) | 2.50 (0.51) | 2.36 (0.49) | 2.16 (0.37)a) | 2.20 (0.41)a) |
| Time of brushing (minute) | 1.85 (0.73) | 2.27 (0.57) | 2.41 (0.52) | 2.02 (0.80) | 3.00 (0.58)a) | 2.82 (0.48)a) |
| Use of interdental brush (%) | 63 | 67 | 63 | 56 | 40 | 48 |
| Use of dental floss (%) | 29 | 40 | 54 | 24 | 24 | 24 |
| Use of water irrigation device (%) | 0 | 0 | 0 | 0 | 0 | 0 |
| Use of toothpicks (%) | 8 | 0 | 0 | 8 | 4 | 4 |
| Use of mouthwash (%) | 13 | 13 | 8 | 24 | 12 | 12 |
| Patient compliance for tooth brushing (%) | 95.2 (4.6) | 96.1 (6.1) | 98.7 (3.5)a) | 99.5 (1.1) | ||
a)Statistically significant compared to the manual toothbrush group at the same time.
Reduction in clinical parameters between baseline and post-baseline follow-up points.
| Clinical parameters | Base to 1 month | 1 month to 2 months | Base to 2 months | |||
|---|---|---|---|---|---|---|
| Mean ± SD | Mean ± SD | Mean ± SD | ||||
| mPI | ||||||
| Manual | 0.67 ± 0.85 | < 0.001 | 0.09 ± 0.68 | 0.439 | 0.76 ± 0.90 | < 0.001 |
| Powered | 1.07 ± 0.91 | 0.001 | 0.20 ± 0.71 | 0.134 | 1.27 ± 0.87 | < 0.001 |
| | 0.104 | 0.499 | 0.043 | |||
| mSBI | ||||||
| Manual | 0.48 ± 0.91 | 0.006 | 0.09 ± 0.77 | 0.491 | 0.58 ± 0.79 | 0.001 |
| Powered | 0.63 ± 0.61 | < 0.001 | 0.30 ± 0.60 | 0.013 | 0.93 ± 0.87 | < 0.001 |
| | 0.300 | 0.242 | 0.100 | |||
a)Mann-Whitney test, used for comparison between the groups.
b)Wilcoxon signed rank test, used for comparison within the groups.
mPI: modified plaque index, mSBI: modified sulcus bleeding index, SD: standard deviation.
Figure 1Clinical assessments of the modified plaque index (mPI) and the modified sulcus bleeding index (mSBI) at the implant sites by visit and group. An overall pattern of reduction in the mPI and mSBI was observed post-baseline in both groups. In addition, in the powered toothbrush group, a statistically significant reduction of the mSBI was found between one month and two months of follow-up.
a)P<0.05 compared to the baseline in the manual toothbrush group.
b)P<0.05 compared to the baseline in the powered toothbrush group.
c)P<0.05 compared to the baseline and one month of follow-up in the powered toothbrush group.