Literature DB >> 23919802

A comparison of obstetrical outcomes with labor induction agents used at term.

Farnaz K Aghideh1, Patrick M Mullin, Sue Ingles, Joseph G Ouzounian, Neisha Opper, Melissa L Wilson, David A Miller, Richard H Lee.   

Abstract

OBJECTIVE: To compare the obstetrical outcomes of term pregnancies induced with one of four commonly used labor induction agents.
METHODS: This is a retrospective cohort study of induced deliveries between 1 August 1995 and 31 December 2007 occurring at the Los Angeles County + University of Southern California Medical Center. Viable, singleton, term pregnancies undergoing induction were identified. Exclusion criteria included gestational age less than 37 weeks, previous cesarean delivery, breech presentation, stillbirth, premature rupture of membranes, and fetal anomaly. Induction methods studied were oxytocin, misoprostol, dinoprostone and Foley catheter. Our primary outcome was cesarean delivery rate among the four induction agents. Secondary outcomes included rate of failed induction, obstetrical complications, and immediate neonatal complications.
RESULTS: A total of 3707 women were included in the study (1486 nulliparous; 2221 multiparous). Outcomes were compared across induction methods using Chi-square Tests (Pearson or Fisher's, as appropriate). Among the nulliparous patients, there was no statistical difference among the four induction agents with regards to cesarean delivery rate (p = 0.51), frequency of failed inductions (p = 0.49), the cesarean delivery frequency for "fetal distress" (p = 0.82) and five minute Apgar score <7 (p = 0.24). Among parous patients, the cesarean delivery rate varied significantly by induction method (p < 0.001), being lowest among those receiving misoprostol (10%). Those receiving oxytocin and transcervical Foley catheter had cesarean rates of 22%, followed by dinoprostone at 18%. The rate of failed inductions was 2% among those receiving misoprostol, compared to 7-8% among those in the other groups (p < 0.01). Although cases of "fetal distress" between the four induction agents was not significantly different amongst multipara women, the cesarean delivery indication for "fetal distress" was higher among multipara receiving misoprostol (p = 0.004). There was no difference among the different induction agents with regards to five minute Apgar <7 (p = 0.34).
CONCLUSION: Among nulliparous women, all induction methods have similar rate of cesarean delivery. The use of misoprostol appears to be associated with a lower risk of cesarean birth among parous women induced at our institution.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23919802     DOI: 10.3109/14767058.2013.831066

Source DB:  PubMed          Journal:  J Matern Fetal Neonatal Med        ISSN: 1476-4954


  8 in total

1.  Using multiple imputation to address the inconsistent distribution of a controlling variable when modeling an infrequent outcome.

Authors:  Yujia Zhang; Sara Crawford; Sheree L Boulet; Michael Monsour; Bruce Cohen; Patricia McKane; Karen Freeman
Journal:  J Mod Appl Stat Methods       Date:  2017

2.  [Clinical efficacy and safety of controlled-release dinoprostone insert: a multicenter retrospective study].

Authors:  Xue-Yuan Li; Yue-Wen Guo; Yan-Wen Xu; Bin Zhu; Xue-Xue Wu; Xiang Chen; Xiao-Yi Wang; Dun-Jin Chen; Hui Chen; Jian-Ping Zhang; Zhi-Jian Wang; Sheng-Li An
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-01-20

3.  Time-to-delivery and delivery outcomes comparing three methods of labor induction in 7551 nulliparous women: a population-based cohort study.

Authors:  C Lindblad Wollmann; M Ahlberg; G Petersson; S Saltvedt; O Stephansson
Journal:  J Perinatol       Date:  2017-08-31       Impact factor: 2.521

4.  Labor Induction with Orally Administrated Misoprostol: A Retrospective Cohort Study.

Authors:  Tove Wallstrom; Hans Jarnbert-Pettersson; David Stenson; Helena Akerud; Elisabeth Darj; Kristina Gemzell-Danielsson; Eva Wiberg-Itzel
Journal:  Biomed Res Int       Date:  2017-09-18       Impact factor: 3.411

5.  Repeated dose of prostaglandin E2 vaginal insert when the first dose fails.

Authors:  Ceyda Karadağ; Sertaç Esin; Yusuf Aytaç Tohma; Ethem Serdar Yalvaç; Tuğrul Başar; Burak Karadağ
Journal:  Turk J Obstet Gynecol       Date:  2021-03-12

6.  Management of Foley catheter induction among nulliparous women: a retrospective study.

Authors:  Heidi Kruit; Oskari Heikinheimo; Veli-Matti Ulander; Ansa Aitokallio-Tallberg; Irmeli Nupponen; Jorma Paavonen; Leena Rahkonen
Journal:  BMC Pregnancy Childbirth       Date:  2015-10-27       Impact factor: 3.007

7.  Comparative study of titrated oral misoprostol solution and vaginal dinoprostone for labor induction at term pregnancy.

Authors:  Xiu Wang; Aijun Yang; Qingyong Ma; Xuelan Li; Li Qin; Tongqiang He
Journal:  Arch Gynecol Obstet       Date:  2016-01-08       Impact factor: 2.344

8.  Misoprostol vaginal insert versus misoprostol vaginal tablets for the induction of labour: a cohort study.

Authors:  Daniele Bolla; Saskia Vanessa Weissleder; Anda-Petronela Radan; Maria Luisa Gasparri; Luigi Raio; Martin Müller; Daniel Surbek
Journal:  BMC Pregnancy Childbirth       Date:  2018-05-10       Impact factor: 3.007

  8 in total